Rain Intensity, FLOW: Data

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 6

Rain Intensity, FLOW

Data:

Pit : PIT 1
Location/Catchment : Catchment area 1
Sump capacity : 65,320 m3
Sump Identification : Void Pit 1
Discharge location : Natural Pond
Kirpich equation: Tc = 0.0195 (L / S0.5) 0.77

the longest distance between top and bottom elv. L = 200 m


Highest level Hh 71 m
Lowest Level Hl 66 m
elevation difference from top to bottom H 5 m
Slope = H/L S = 0.025800000
time to travel TC = 4.71 minutes

Rain Intensity: I = R24/24 (24/TC)2/3

max rain in 24 hours (Jun 2011 - Jun 2019) R = 190 mm


rainfall intensity I = 359.1 mm/hour

Flow Rate: Q = 0.00278 C I A

run off coefficient number C = 0.7


rain intensity I = 359.1 mm/hour
catchment area A = 259971 m2
catchment area = 25.997 Ha
max rain run off discharge Q = 18.17 m3/second
Elevasi Genangan
RL 71

Catchment Area
PUMP CAPACITY
Asumption rainfall intensity max in 1 hour
INPUT HYDROLOGICAL DATA Direct Pumping (Lower sump)
Sump / Pond /Void
Location : PT. BUMI PETANGIS
Required lowest level (RL) : 66
Sump capacity : 65,320 m3
Discharge location (outlet) : Natural pond
The highest level of pipeline (RL) : 71
Rainfall intensity I= 359.1 mm/hour
Catchment area A= 259,971 m2

Inflow (assumed to be 2 hour/day) Q= 130,802 m3/day

INPUT PUMP DATA


Pump 1
Pump type : MF-420 or Equivalent
Pump number : 1 units
Working hours : 18 hrs/day
Flowrate capability : 150 Ltr / sec.
: 540 m3/hour
: 9,720 m3/day
Outflow : 9,720 m3/day
Total Outflow : 9,720 m3/day
PUMPING DAYS
To dewater the inflow : 13.46 day(s)
To dewater existing volume : 6.72 day(s)

Minimum sump capacity to accommodate outflow


: 10,692 m3
(+ 110% outflow)

Pump Type
No Type Total Head Max (m) Flowrate Max (L/s)
1 MF-420 140 280 Selected Type Pump
2 MF-390 120 140
3 MF-290 85 90

You might also like