M.

V ARABIAN SEA
ELECTRICAL REPAIRS FOR LAY UP 2017

RS No. WORK SPECIFICATION QTY REMARKS


BT ROOM BILGE ALARM.
E002 RS 01 A suitable bilge alarm float provision to be provided in the Bow Thruster compartment bilge area. 1

ME CPP CONTROL SYSTEM PANEL ROUTINES


E002 RS 02 Control cabinet internals to be cleaned with appropriate equipments. All contacts to be cleaned. All Relays, timers etc to be checked. 2 PME & SME CPP
Defective ones to be replaced. Performance to be checked and confirmed after the routines for the satisfactory operations. 17 AR 96
ALARM MONITORING SYSTEM
E002 RS 03 MECOS 3000, MAKER – MARINE ELECTRICALS, MUMBAI 1
Fault alarms of the card faults to be checked and cleared. Spares required to be supplied by yard.
1)Rack3_Card7_fault
2)Rack2_Card17_fault
3)Rack2_Card27_fault
OWS 15 PPM
E002 RS 04 MAKE : DECKMA HAMBURG
MODEL No. : OMD-2005 1
Annual calibration due on 18/12/2017. Same to be calibrated and certificate issued.
MAIN & EMERGENCY SWITCH BOARDS-
E002 RS 05 CAPACITY / DETAILS : 415V , 50 HZ , 3 PHASE
A) Performance of the Bus coupler of the M.S.B in the ECR to be checked and confirmed. M.S.B. and Emergency Switchboard to be
cleaned. All connections on the bus bar and individual circuit breakers to be checked for tightness. Insulation readings to be
measured and recorded. If the insulation is low, same to be improved to the recommended value by rectifying the defect. Any
defective lug / Screw found, to be renewed.
B) Insulation readings of all Electrical Cables on the switch boards to be measured and record submitted. Insulation to be improved 2
as required. Cables to be renewed if found required with the approved standard cables for the M.S.B./E.S.B

M.A.FAHEEM K. RAGHU VARMA


ELECTRICAL OFFICER CHIEF ENGINEER

M.V ARABIAN SEA LAY UP REPAIRS (ELECTRICAL) 2017


Page 1 of 2
A/E CONTROLS 1
E002 RS 06 1) A/E No.1- during load sharing when the command for off load is given, sometimes it does not off load and the MSB abnormal
alarm activates. To inspect and rectify.

MAIN TRANSFORMERS 2
E002 RS 07 CAPACITY / DETAILS : 415 V / 220 V , 120 KVA EACH, 3 PHASE, 50 Hz
2 Nos Transformers to be cleaned. Connections, links, wirings to check.
EMERGENCY TRANSFORMERS 2
E002 RS 08 CAPACITY / DETAILS: 415 V / 220 V, 30 KVA EACH, 3 PHASE, 50 Hz
2 Nos Transformers to be cleaned. All connections, links, wirings to check.
FREEZER ROOM 3 YARD TO PROCURE AND
E002 RS 09 Meat, veg and fish rooms man trap alarm switch and switch boxes to renew with appropriate approved type switch and switch box. SUPPLY
FREEZER ROOM 1
E002 RS 10 Temperature gauge of the fish room to be shifted to the lobby area outside the meat room.
FREEZER ROOM 1
E002 RS 11 To renew the fish room door packing with an approved type of packing.
TANK LEVEL INDICATORS IN ECR
E002 RS 12 3 Nos indicators found faulty. To check and rectify/ renew as done in Lakshadweep Sea.
JUNCTION BOXES 4
E002 RS 13 4 Nos. of junction boxes of life raft davits to be renewed. Approximate size: 4 x 4 inches with suitable weather proof material.
E002 RS 14 ELECTRIC ANCHOR WINDLASS AND VERTICAL CAPSTAN (MACGREGOR) (Refer RS No. 17AR54 dtd
DETAILS: MAC GREGOR REFERENCE NO.P4494, HULL NO. 209, PROJECT NAME: 250 PASSENGER CUM 100T CARGO VESSEL. 03/10/2017)
BUYER:COLOMBO DOCKYARD PLC. DESIGNED AND BUILT BY: MAC GREGOR PLIMSOLL PTE LTD.
EQUIPMENT SR. NO.ELECTRIC ANCHOR WINDLASS-P4494-EAW/GG-36U3.
ELECTRICAL VERTICAL CAPSTAN-P4494-EVC-5T, YEAR BUILT: 2008.
Modification to be carried out as per service Engineer’s report.
E002 RS ELECTRIC MOTORS
15 Electric Motors as per attached list to be overhauled. Bearings & oil seals to be renewed as applicable- yard supply.
Worn & damaged parts to be repaired suitably.
BLOWER & FANS:
E002 RS Blowers along with motors as per attached list to be overhauled. Bearings & seals to be renewed as applicable - yard supply
16 Blower impellers to dynamically balance. Impellers/casings/ & other worn/damaged parts to be repaired /renewed.