LSV200-150-381A 377@36.3 - 1B SS Impeller

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Pump Performance:According to ISO9906-2012,Grade 1B

Pump Performance Datasheet


Customer Quote number
Customer Reference Pump size LSV200-150-381A
Item number Stages 1
Service Based on curve number 1
Quantity of pumps Data last saved 2022-1-6
Operating Conditions Liquid
Flow 377 m3/h Liquid type Water
Head(requested) 36.3 m Additional liquid description
Head(actual) 36.3 m Solids diameter,max 0 mm
Suction pressure,rated/max Temperature 20 C
NPSH available,rated Ample m Fluid density,rated/max 1000.00 kg/m3
Frequency 50 HZ Viscosity,rated 1.0 cst
Performance Material
Pump speed,rated 1480 rpm Casing Material DI
Impeller diameter,rated 335.2 mm Impeller Material SS
Impeller diameter,maximum 381.0 mm Pressure Data
Impeller diameter,minimum 280.0 mm Flange Rating PN25
Efficiency 83.38 % Maximum working pressure 0.41 MPa
NPSH 3.9 m Maximum allowable working requested 2.50 MPa
- - Maximum allowable suction pressure limit 2.09 MPa
MCSF 201.70 m3/h Casing hydrostatic test pressure 3.75 MPa
Head Maximum,rated diameter 41.6 m
Driver&Power Data
Head rise to shut off 89.95 %
Driver sizing specification 250M
Flow,best eff.Point(BEP) 394.48 m3/h Margin over specification 1.23
Flow ratio(rated/BEP) 95.57 % Service factor
Head ratio(rated/Max Diameter) 73.29 % Power,hydraulic 37.25 kW
Diameter ratio(ratio/max) 87.98 % Power,rated 44.68 kW
Viscous coefficients(CQ/CH/CE) 1.0/1.0/1.0 Power,maximum 52.68 kW
Selection status Acceptable Min recommended driver 55.00 kW

P(kW)
75

60

45

30

15
0
0 100 200 300 400 500 600 700 800 900 1000

H(m) Eff(%)
70 100

63

56 80

49

42 60

35 381.00mm

28 40

335.22mm
21

14 280.00mm 20

0 0
0 100 200 300 400 500 600 700 800 900 1000

NPSH(m) Q(m3/h)
12.5
10.0
7.5
5.0
2.5
0.0
0 100 200 300 400 500 600 700 800 900 1000

Printed from Grundfos Selector [V5.1_CSU.2021-07-15] Motor Sizing Method:ISO 5199


1/1

You might also like