Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
1.4 Emergency Telephone Continued:
Page 2 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
1.5 Emergency Poison Control Centers Phone Numbers:
Country Organization Address Phone/ Fax Number
Bulgaria National Toxicology Hospital for Active Medical Tel/ fax: +359 2 9154 409
Center Treatment and Emergency
Medicine "N.I.Pi rogov"
Sofia - 1000
Croatia Croatian Institute for 10000 Zagreb Fax: + 385 01 46 41 368
Toxicology and Borongajska cesta 83 g
Antidoping
Estonia Poisoning Information Centre Gonsiori 29, 15027 Tallinn, Tel: +372 62 69 379
Health Board Estonia
Page 3 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
1.5 Emergency Poison Control Centers Phone Numbers Continued:
Country Organization Address Phone/ Fax Number
Greece General Chemical An. Tsoha 16, GR- Tel:+30 210 6479409,
State Laboratory, 115 21 Fax:+30 210 6466917
Directorate of Athens
Environment, section
B
Hungary National Institute of Nagyvárad tér 2 None Shown
Chemical Safety BUDAPEST
(HU: Országos H-1096
Kémiai Biztonsági
Intézet, OKBI)
Ireland Beaumont Hospital - Beaumont Road, Tel:+353 1 8092566
National Poisons Dublin 9,
Information Centre
Italy Istituto Superiore di Viale Regina Elena, 299 Tel:+39 0649906140 and
Sanità, I-00161 ROMA +39 0649902064
National Center for
Chemicals
Latvia Latvian Environment, Maskavas Street 165 Tel:+371 67032600
Geology and Riga, LV-1019
Meteorology Centre
(LEGMC)
Lithuania Environmental Juozapavi iaus st. 9, LT- Tel:+ 370 70662008
Protection Agency 09311 Vilnius, Lithuania Fax:+ 370 70662000
Page 4 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
1.5 Emergency Poison Control Centers Phone Numbers Continued:
Portugal Centro de Rua Almirante Barroso, n.º Tel:+ 351 213 303 271
Informação 36
Antivenenos Instituto
1000-013 Lisboa -
Nacional de
Emergência Médica Portugal
Page 5 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
Section 2 - Hazards Identification
2.1 Classification of the blend
Classification according to Regulation EU) No 1272/2008
Additional Information: For full text of H and P codes see sections 2.2 2.3,16
2.2 Pictograms
Hazard statements
H225: Highly flammable liquid and vapor
H304: May be fatal if swallowed and enter the airway
H312: Harmful in contact with skin
H315: Causes skin irritation
H319: Causes serious eye irritation
H336: May cause drowsiness or dizziness
H340: May cause genetic defects
H350: May cause cancer
H411: Toxic to aquatic life with long lasting effects
Precautionary statements:
P102: Keep out of reach of children
P201: Obtain special instructions before use. READ SDS BEFORE USE
P202: Do not handle until all safety precautions have been read and understood
P210: Keep away from sparks and open flames- No smoking
P240: Ground or bond container and receiving equipment
P241: Use explosion-proof equipment
Page 6 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
P242 Use only non-sparking tools
P243 Take precautionary measures against static discharge
P260: Do not breathe vapors
P264: Wash hands thoroughly after handling
P270: Do not eat, drink or smoke when using this product
P271: Use only outdoors or in well ventilated area
P273: Avoid release to the environment
P280: Wear protective gloves, clothing and eye protection
3.1 Substances
Chemical Names Inde EC No. REACH No. CAS No % Classification
x No.
Blend of Aliphatic and N/A N/A N/A N/A 94-97% None
Aromatic Hydrocarbons C-2
to C-20
Tricarbonyl None 235-166-5 Below 12108-13-3 3-6% Acute Tox. 3 H301,
(methylcyclopentadienyl) Listed Tonnage Acute Tox. 2 H310,
manganese Requirements Acute Tox. 1 H330,
Aquatic Chronic 1 H410,
Aquatic Acute 1 H400
Page 7 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
3.2 Blend
Chemical Names Index No. EC No. REACH No CAS No Classification
Naphtha (petroleum), 649-282-00-2 203-625-9 01-2119485026-38- 68527-27-5 Asp. Tox. 1 H304,
full-range alkylate XXXX Muta 1B H340,
Carc1B H350,
Solvent naphtha 649-356-00-4 265-199-0 Below Tonnage 64742-95-6 Asp. Tox. 1 H304,
(petroleum), light Requirements Muta 1B H340,
aromatic Carc1B H350
3.3 Trade Secret Provision and Chemical Concentration Disclosure: In accordance with OSHA and GHS
Regulations we have withheld specific percentages of the chemicals in this mixture. The chemical concentrations
have been disclosed as a blend and are applicable to the hazards as identified in this Safety Data Sheet.
4.2 Most important symptoms and effects, both acute and delayed: The severity of outcome following an
exposure may be more related to the time between the exposure and treatment, rather than the amount of the
exposure. Therefore, there is a need for rapid treatment of any exposure.
4.3 Indication of any immediate medical attention and special treatment needed: Note to Physicians: If you
determine that a medical emergency exists and the specific chemical identity is necessary for emergency or first-aid
treatment we will immediately disclose the specific chemical identity. Call CHEMTREC 800-424-9300 or +1-703-527-
3887. We will require a written statement of need and confidentiality agreement, in accordance with OSHA’s Trade Secret
Regulations as soon as circumstances permit. In non-emergency situations, we will upon written request disclose a specific
chemical identity.
Page 8 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
Section 5 - Fire-Fighting Measures
5.1 Extinguishing media: Carbon dioxide, dry chemical, foam. Use water to cool containers exposed to fire
5.2 Special hazards arising from the substance or mixture: Avoid fumes of burning product.
5.3 Advice for fire-fighters: Fire fighters should wear full-face, self-contained breathing apparatus and
impervious protective clothing. Fire fighters should avoid inhaling any combustion products.
6.2 Spills: Avoid direct contact with material. Stop leak if without risk. Move containers from spill area. Prevent
entry into sewers or waterways. Contain and collect spillage with non-combustible, absorbent material such as
sand, earth, vermiculite or diatomaceous earth and place in a container for disposal.
7.2 Conditions for safe storage, including any incompatibilities: Store in a tightly closed container in a cool,
dry and well-ventilated area.
Page 9 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
8.2. Exposure control
Ventilation: Provide general or local exhaust ventilation systems to maintain airborne concentrations below
TLV/PELs Local exhaust ventilation are preferred because it prevents contaminant dispersion into the work area
by controlling it at its source.
Contaminated Equipment: Separate contaminated work clothes from street clothes and launder before reuse.
Remove this material from your shoes and clean personal protective equipment.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose
combination (US) or type AXBEK (EN 14387) respirator cartridges as a backup to engineering controls. If the
respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components
tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Hand protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique to avoid skin
contact
with this product. Dispose of contaminated gloves after use. Select gloves tested to the ANSI/ISEA 105-2011 or
European EN374 Standard.
Full contact: Viton
Splash contact: Viton
Registered trademark of The Chemours Company FC, LLC.
Eye protection
Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate
government standards such as NIOSH (US) or EN 166(EU).
Page 10 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
10.2 Chemical stability: Stable under ordinary conditions of use and storage.
10.3 Possibility of hazardous reactions: Hazardous polymerization has not been reported.
10.4 Conditions to avoid: Avoid heat, sparks open flames and other ignition sources
10.6 Hazardous decomposition products: Combustion produces carbon monoxide and carbon dioxide.
OECD Guideline Test results found in the European Chemical Agency Data Base shows that no components of
this product to cause Harmful Oral Toxicity.
OECD Guideline Test results found in the European Chemical Agency Data Base shows that components of this
product to cause Harmful Dermal Toxicity.
OECD Guideline Test results found in the European Chemical Agency Data Base shows that no components of
this product to cause Harmful Inhalation Toxicity
Aspiration Hazard: European Chemical Agency Data Base shows that components of this product may be fatal if
swallowed and enters airways.
Mutagenicity: OECD Guideline Test results found in the European Chemical Agency Data Base show
components of this product to cause genetic defects.
Skin Corrosion/Irritation: OECD Guideline Test results found in the European Chemical Agency Data Base
shows that components of this product to cause skin irritation. Repeated exposure may cause skin dryness or
cracking.
Serious Eye Damage/Irritation: OECD Guideline Test results found in the European Chemical Agency Data
Base shows that components of this product to cause serious eye irritation.
Reproductive toxicity: OECD Guideline Test results found in the European Chemical Agency Data Base show
no components of this product to cause damage to fertility or the unborn child.
Page 11 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
Skin Sensitisation OECD Guideline Tests results found in the European Chemical Agency Data Base show no
components of this product to cause skin sensitivity.
Respiratory Sensitisation OECD Guideline Tests results found in the European Chemical Agency Data Base
show no components of this product to cause respiratory sensitivity.
Specific Target Organ Toxicity (Single Exposure): European Chemical Agency Data Base shows that
components of this product may cause damage to the central nervous system (CNS).
Specific Target Organ Toxicity (Repeated Exposure): European Chemical Agency Data Base shows that no
components of this product may cause damage to organs due to repeat exposure. However, may contain
materials which may cause damage to the following organs: kidneys, lungs, liver, upper respiratory tract, skin,
eyes, central nervous system (CNS).
Signs and Symptoms: Effects due to exposure may include: Headache, Dizziness, Drowsiness, Metabolic
Acidosis, Coma, Seizures. Symptoms may be delayed
Carcinogenicity: OECD Guideline Test results found in the European Chemical Agency Data Base shows that
components of this product to cause cancer.
Page 12 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
ID No.: UN 3295
Shipping Name: Hydrocarbons, liquid, n.o.s.
Hazard Class: 3
Packing Group: II
Flash Point: -40 °C - closed cup
Marking: Marine Pollutant Naphtha (petroleum), full-range alkylate
Label: Flammable
Placard: Flammable
Classification Code: F1
ID No.: UN 3295
Shipping Name: HYDROCARBONS, LIQUID, N.O.S.
Hazard Class: 3
Packing Group: II
Flash Point: -5.5 °C - closed cup
EmS Number: F-E, S-D
Marking: Marine Pollutant Naphtha (petroleum), full-range alkylate
Label: Flammable
Placard: Flammable
Australian Dangerous Goods Cod
Page 13 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
15.2 Chemical safety assessment: For this substance, a chemical safety assessment is not required.
Section 16 - Other Information
16.1 This safety data sheet is drawn up to comply with the requirements Commission Regulation (EU) No 830/2015
of 28 May 2015.
16.2 Key or legend to abbreviations and acronyms used in the safety data sheet:
ADR: European Agreement concerning international carriage of Dangerous goods by Road
UN: The United Nations
CAS: Chemical Abstracts Service
EC: European Community
H: Hazard Statement
P: Precautionary statements
IMDG: International Maritime Dangerous Goods
16.3 Key literature references and sources for data: CHEMpendium data base of Canadian Centre for Occupational
Health and Safety (CCOHS), JJ Keller on Line, European Chemical Agency Data Base and MSDS and SDS of
chemicals in this mixture.
16.4 Classification for mixtures and used evaluation method according to regulation (EC) 1272/2008 [CLP]: See SECTION
2.1 (classification).
Page 14 of 15
Octanium Unleaded
Compliant with Regulation (EU) No 830/2015
Compliant with CLP Regulation (EU) No 1272/2008
16.5 Relevant H and P Codes (number and full text):
Hazard statements
H225: Highly flammable liquid and vapor
H304: May be fatal if swallowed and enter the airway
H312: Harmful in contact with skin
H315: Causes skin irritation
H319: Causes serious eye irritation
H336: May cause drowsiness or dizziness
H340: May cause genetic defects
H350: May cause cancer
H411: Toxic to aquatic life with long lasting effects
Precautionary statements:
P102: Keep out of reach of children
P201: Obtain special instructions before use. READ SDS BEFORE USE
P202: Do not handle until all safety precautions have been read and understood
P210: Keep away from sparks and open flames- No smoking
P240: Ground or bond container and receiving equipment
P241: Use explosion-proof equipment
P242 Use only non-sparking tools
P243 Take precautionary measures against static discharge
P260: Do not breathe vapors
P264: Wash hands thoroughly after handling
P270: Do not eat, drink or smoke when using this product
P271: Use only outdoors or in well ventilated area
P273: Avoid release to the environment
P280: Wear protective gloves, clothing and eye protection
16.6 Training advice: None