Professional Documents
Culture Documents
Electrical Condition Monitoring Analysis
Electrical Condition Monitoring Analysis
Electrical Condition Monitoring Analysis
OBSERVATION DATA
AREA : MAIN CRUSHER 2 MOTOR POWER : 30 KW DATE : 22-Jan-2022
TAG NUMBER : 212_FN2_M1 MOTOR SPEED : 1481 RPM INSPECTOR : FERRY HB
EQUIPMENT NAME : FAN LOAD : APPROVED : ARDI P
SOLO RUN MOTOR ONLY BEFORE TIGHTENING THE FOUNDATION BOLTS
MEASUREMENT POSITION NDE DE
HORIZONTAL VELOCITY (mm/s) 1,058 0,931
VERTICAL VELOCITY (mm/s) 1,773 2,088
AXIAL VELOCITY (mm/s) 0,836 0,553
HORIZONTAL SHOCK PULSE MAX -15 CARPET -25 MAX -19 CARPET -28
RUNNING MOTOR & BEARING FAN DAMPER OPEN 100% BEFORE MAKESURE TIGHTENING THE FOUNDATION BOLTS
MEASUREMENT POSITION NDE DE FIX BEARING FREE BEARING
HORIZONTAL VELOCITY (mm/s) 1,92 0,879 0,978 2,527
VERTICAL VELOCITY (mm/s) 2,79 2,106 2,723 2,723
AXIAL VELOCITY (mm/s) 1,847 1,597 1,556 1,729
HORIZONTAL SHOCK PULSE MAX -9 CARPET -22 MAX -19 CARPET -28 MAX -15 CARPET -28 MAX -19 CARPET -29
RUNNING MOTOR & BEARING FAN DAMPER OPEN 100% AFTER MAKSURE TIGHTENING THE FOUNDATION BOLTS
MEASUREMENT POSITION NDE DE FIX BEARING FREE BEARING
HORIZONTAL VELOCITY (mm/s) 1,748 0,904 0,938 2,556
VERTICAL VELOCITY (mm/s) 2,405 2,032 2,539 2,477
AXIAL VELOCITY (mm/s) 1,432 1,644 1,682 1,77
HORIZONTAL SHOCK PULSE MAX -12 CARPET -24 MAX -13 CARPET -23 MAX -18 CARPET -29 MAX -20 CARPET -30
HORIZONTAL FREE BEARING VELOCITY SPECTRUM VIBRATION LIMIT CHART ISO 10816-3
CONCLUSION
SUSPECT PROBLEM RECOMMENDATION
1. LOOSENESS STRUCTURAL 1. CHECK THE BOLTS FOUNDATION TIGHTNESS
FRAME FREE BEARING MEASUREMENT FRAME FIX BEARING MEASUREMENT FRAME DE MEASUREMENT FRAME NDE MEASUREMENT
FRAME FREE BEARING MEASUREMENT FRAME FIX BEARING MEASUREMENT FRAME DE MEASUREMENT FRAME NDE MEASUREMENT