Proflo: Wiring Diagram 24 VDC Power

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

proflo 24 VDC POWER wiring diagram

Wiring Schematic and Battery Instructions for 24 VDC proflo PF-1 to PLC, Murphy
or Altronic control panel on the divider block or mounted in control panel.
The 24 VDC proflo uses 2 “AA” lithium batteries for Back-up Power to the micro processor
FIG. A
when the control panel power is turned off or if the power fails. These batteries are
for back-up power only and cannot be used to power the 24 VDC proflo. The life of
these batteries are approximately 24 months when the proflo is not powered by the
control panel. When it becomes necessary to replace the back-up batteries use the L91
Energizer Lithium “AA” ONLY. (SEE FIG. A.)
DO NOT Overtighten Screws on the cover plate!
If the batteries are drained to ZERO and are not replaced before the compressor is
started the trending information will not be accurate. If the Battery voltage drops it
Battery
does not affect the proflo’s ability to protect the compressor for no-flow shut down. Cover Screws
Inside Battery Back-up Battery
Compartment L91 Lithium “AA”

The wiring schematic


is universal and will Control Panel or
work with most control
panels. To avoid
PLC INPUT
Model-PF1

destroying the proflo IrDA PORT


US Copyright Registered 2001
Patent Pending
Set
MODULE
prO !
Button

by incorrect wiring or if
R

you have a proprietary


flO
C US
203633
CL I, DIV 2 Grps A, B, C, D
o
T4A Max 85 C Amb.

control device please Mode


Button
R E F E R TO M A N U A L F O R P R O P E R O P E R AT I O N & B AT T E RY T Y P E CAUTION: DO NOT CONNECT
! WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT WHILE CIRCUIT IS LIVE

contact CPI. PULSE OUTPUT, ( BLUE WIRES )


UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS
BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-HAZARDOUS

AND ALARM CIRCUIT ( RED WIRES )


AT THE SAME TIME
BLUE
BLUE PULSE OUTPUT TO PLC TO MONITOR DIVIDER BLOCK CYCLE (Use Edge Trigger)
PURPLE
18 TO 24 VDC POWER
PURPLE Non-Polarity Sensitive

WHITE
RED ALARM CIRCUIT - LUBE NO FLOW TO CONTROL PANEL
RED
PROXIMITY SWITCH
GREEN

WHITE
US Patent # 6,823,270 B1
See proflo operation brochure for N/O - N/C wiring instructions
GREEN

GREEN ! REFER TO MANUAL FOR PROPER OPERATION. WARNING - EXPLOSION HAZARD - DO NOT
DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS

Guaranteed to work flawlessly GROUND


with All Manufacturers Divider Blocks
Ariel - SB - Graco/Trabon - Lincoln - DropsA
(2) WHITE WIRES...............to Proximity Switch on Divider Block
(2) RED WIRES....................to Control Panel Alarm Circuit
NOTE: The 24 VDC proflo Pf1 can (2) GREEN WIRES..............to Ground
be mounted in the control panel (2) BLUE WIRES..................Pulse Output to PLC or new Murphy control panel
or directly on the divider block. (2) PURPLE WIRES............18 to 24 VDC .5 amp Max Power Input

CAUTION: • DO NOT connect blue wires and red wires to control panel at the same time.
• All unused wires must be isolated from contact with each other and isolated from ground.

! • NEVER WELD ON THE COMPRESSOR SKID OR FRAME WITH ANY WIRING CONNECTED!
Welding will cause premature or immediate failure of the proflo alarm circuits.

CPI Worldwide Headquarters - 4410 Greenbriar Drive, Stafford, TX 77477, USA