Professional Documents
Culture Documents
Load Calculation - Akash Jadhav 04
Load Calculation - Akash Jadhav 04
BEDROOM 2
Lumens /Watt KITCHEN
Electrical Lighting Calculation
Space Tube Lights Down Lights Decorative lights Foot Lamps Other FOYER
18 Watts 10 Watts 25 Watts 3 Watts 3
Bed room1 4 1 M.BEDROOM
Bed Room 2 4 1
Master Bed Room 4 1
Living / Dinning 8 1 BEDROOM 1
Kitchen 1
guest room 1 2
Toilet 1 1 GUEST ROOM
LIVING ROOM
Toilet 2 1
Foyer 2 1
Total Fixtures 2 22 0 5 4
Total Wattage 36 154 0 15 12
Total 217
LPD 3.1 Watts / Sq ft
Fan
Space 40 Watts Refrigerator Oven Water purifire Gyser Mixer Exhaust Fan Induction Washing Machine
Dish washer iron TV
Bed room1 1 1 1
Bed Room 2 1 1
Master Bed Room 1 1
Living / Dinning 2 2
Kitchen 1 1 1 1 0 1 1 1 1 1
guest room 0 1
Toilet 1 0 1
Toilet 2 0 1
Foyer 0
Wattage 240 350 1000 50 4000 750 90 1200 1000 1000 750 200 10390
Coonected Load
Lighting 217
Equipment Load 10390
Total 10607
00 hrs 1 hrs 2 hrs 3 hrs 4 hrs 5 hrs 6 hrs 7 hrs 8 hrs 9 hrs 10 hrs 11 hrs 12 hrs 13 hrs 14 hrs 15 hrs 16 hrs 17 hrs 18 hrs 19 hrs 20 hrs 21 hrs 22 hrs 23 hrs 24 hrs
Lighting Schedule
Bed room 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 6
Kitchen 1 1 1 1 1 1 6
Living/Dining 1 1 1 1 4
Toilets & other spaces 1 1
Total Occupants 8
1 lit
1 deg
Enegy 4200 Joules