Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Hydraulic Mining Excavators

CAMP/ SIL – Electric System CAT-6040FS AC

Active Power Converter

Sebastian Fillinger - 2014


Active Power Converter Overview Service Training

The Active Power Converter transforms the Motor Power and Voltage in an analog Signal

2
Active Power Converter Location Service Training

The Active Power Converter is located in the 400V Cabinet

3
Operating Mode Service Training

Motor Activ Power Drive Controller Main Pumps


Converter (Pump Management
P = U * I * cosφ * √3 * η
System)

Voltage Power Signal


Current

4-20mA

A
Voltage Signal
4-20mA

7200V
Power
Supply
V

4
Electrical Schematic Service Training

5
PMS Power (APC Output) 4-20mA Service Training

6
Output Diagram (Active Power) Service Training

Active power
20mA @ 133% Load
25 (1862KW)

16mA @ 100% Load


(1400KW)
20

15

4mA @ 0% Load
(0KW)
10

0
0 500 1000 1500 2000 2500 3000

7
PMS Voltage (APC Output) 4-20mA Service Training

8
Output Diagram (Voltage) Service Training

Voltage
8000

7000
20mA @ 107% of
nominal voltage
(7704V)
6000

5000
16mA @ 100% of
nominal voltage
(7200V)
4000
4mA @ 80% of
nominal voltage
(5760V)
3000

2000

1000

0
0 5 10 15 20 25

9
Questions? Service Training

Questions are free of charge!!!