Battery Pack Report: General Info
Battery Pack Report: General Info
GENERAL INFO
1 | TEAM FORMATION
2 | PROBLEM DESCRIPTION
ASSIGNED TO
After completion of all electrical tests, there is a problem with grounding (isolation issues)
Alexandr Korolchuk
between positive node and universal ground (Figure1). The voltage is increasing on node after
each run (charge and discharge of battery), The voltage on node was measured when the battery DATE EFFECTIVE
was fully disconnected from all sources of energy. Thats means there is still connection which is
not managed by Master BMS well enough. When control cable (Figure 2) is disconnected from 10.11.2021
Master BMS, there is no voltage on the positive node. Cells are okay, Other components are also LEAD NOTIFIED?
okay in this case.
YES
ASSIGNED TO
Jan Guger
DATE EFFECTIVE
Removal of batteries with isolation problem from production chain.
15.11.2021
LEAD NOTIFIED?
YES
ASSIGNED TO
Alexandr Korolchuk
xelectrix Power GmbH suspects there is isolation problem inside of battery pack, which makes
internal safety operating with faults due to Master BMS failure control, usage of unreliable cables DATE EFFECTIVE
and connections outside surface of contactors around Master BMS. Master BMS could also have
issues itself. On average each tested battery has 20V capacitive to ground in DC. The worst case 15.11.2021
was 200V capacitive to ground. LEAD NOTIFIED?
was 200V capacitive to ground.
YES
ASSIGNED TO
Jan Guger
xelectrix Power Gmbh changed the cables of Master Unit. The voltage dropped from 8V to 2,4V.
Then, change of rings and cables on contactors lead to voltage reduction from 2,4V to 1.3V. That DATE EFFECTIVE
means there is still internal isolation issue between ground and node which is still not managed by 15.11.2021
MASTER BMS, and the problem was not fully eliminated using of hardware efforts.
LEAD NOTIFIED?
YES
ASSIGNED TO
Jan Guger
The system still has problems after all reparations done, All possible hardware repairments were DATE EFFECTIVE
done. Maybe redesign of safety construction can help to make system operate in the safe state. 15.11.2021
LEAD NOTIFIED?
YES