Pip Ctce1000-2018

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 54

TECHNICAL REVISION

August 2018

Coatings

PIP CTCE1000
External Coating System
Selection Criteria
PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES

In an effort to minimize the cost of process industry facilities, this Practice has been
prepared from the technical requirements in the existing standards of major industrial users,
contractors, or standards organizations. By harmonizing these technical requirements into a single
set of Practices, administrative, application, and engineering costs to both the purchaser and the
manufacturer should be reduced. While this Practice is expected to incorporate the majority of
requirements of most users, individual applications may involve requirements that will be appended
to and take precedence over this Practice. Determinations concerning fitness for purpose and
particular matters or application of the Practice to particular project or engineering situations should
not be made solely on information contained in these materials. The use of trade names from time
to time should not be viewed as an expression of preference but rather recognized as normal usage
in the trade. Other brands having the same specifications are equally correct and may be substituted
for those named. All Practices or guidelines are intended to be consistent with applicable laws and
regulations including OSHA requirements. To the extent these Practices or guidelines should
conflict with OSHA or other applicable laws or regulations, such laws or regulations must be
followed. Consult an appropriate professional before applying or acting on any material contained
in or suggested by the Practice.

This Practice is subject to revision at any time.

© Process Industry Practices (PIP), Construction Industry Institute, The University of Texas at
Austin, 3925 West Braker Lane (R4500), Austin, Texas 78759. PIP Member Companies and
Subscribers may copy this Practice for their internal use. Changes or modifications of any kind are not
permitted within any PIP Practice without the express written authorization of PIP. Authorized Users
may attach addenda or overlays to clearly indicate modifications or exceptions to specific sections of
PIP Practices. Authorized Users may provide their clients, suppliers and contractors with copies of the
Practice solely for Authorized Users’ purposes. These purposes include but are not limited to the
procurement process (e.g., as attachments to requests for quotation/ purchase orders or requests for
proposals/contracts) and preparation and issue of design engineering deliverables for use on a specific
project by Authorized User’s client. PIP’s copyright notices must be clearly indicated and
unequivocally incorporated in documents where an Authorized User desires to provide any third party
with copies of the Practice.

PUBLISHING HISTORY
February 2001 Issued July 2006 Reaffirmation with Editorial August 2013 Editorial Revision
Revision
April 2001 Editorial Revision June 2007 Editorial Revision August 2018 Technical Revision
July 2005 Technical Correction November 2012 Reaffirmation with Editorial
Revision

Not printed with State funds


TECHNICAL REVISION
August 2018

Coatings

PIP CTCE1000
External Coating System
Selection Criteria
Table of Contents
CTCE1000-D012M – Severe/Seacoast
1. Scope ...........................................3 Environment Selection Criteria (SI Units)
CTCE1000-D013 – Offshore Environment
2. References ..................................3 Selection Criteria (US Customary Units)
2.1 Process Industry Practices ...............3 CTCE1000-D013M – Offshore Environment
2.2 Industry Codes and Standards .........3 Selection Criteria (SI Units)
CTCE1000-D014 – Moderate Environment
3. Definitions ...................................3 Selection Criteria (US Customary Units)
CTCE1000-D014M – Moderate Environment
4. Requirements ..............................3
Selection Criteria (SI Units)
Data Forms CTCE1000-D021 – Severe Environment
Selection Criteria Purchaser Defined (US
CTCE1000-D001 – Documentation Customary Units)
Requirements Sheet CTCE1000-D021M – Severe Environment
The following data forms shall be part of this Selection Criteria Purchaser Defined
Practice only if indicated on the purchaser’s (SI Units)
completed Documentation Requirements Sheet. CTCE1000-D022 – Severe/Seacoast
Environment Selection Criteria Purchaser
CTCE1000-D002 – Coating Type Code Defined (US Customary Units)
Definitions
CTCE1000-D011 – Severe Environment CTCE1000-D022M – Severe/Seacoast
Selection Criteria (US Customary Units) Environment Selection Criteria Purchaser
Defined (SI Units)
CTCE1000-D011M – Severe Environment
Selection Criteria (SI Units) CTCE1000-D023 – Offshore Environment
Selection Criteria Purchaser Defined (US
CTCE1000-D012 – Severe/Seacoast
Customary Units)
Environment Selection Criteria
(US Customary Units) CTCE1000-D023M – Offshore Environment
Selection Criteria Purchaser Defined
(SI Units)

Process Industry Practices Page 1 of 4


CTCE1000-D024 – Moderate Environment
Selection Criteria Purchaser Defined (US
Customary Units)
CTCE1000-D024M – Moderate Environment
Selection Criteria Purchaser Defined
(SI Units)
CTCE1000-D025 – Purchaser Defined
Environment Selection Criteria (US
Customary Units)
CTCE1000-D025M – Purchaser Defined
Environment Selection Criteria (SI Units)

Process Industry Practices Page 2 of 4


PIP CTCE1000 TECHNICAL REVISION
External Coating System Selection Criteria August 2018

1. Scope
This Practice describes the criteria for the selection of industrial coating systems for insulated and
uninsulated substrates of structural steel, equipment, vessels, tanks, and piping. This Practice does
not include criteria for the selection of industrial coating systems for internal linings, underground
substrates, maintenance coating, architectural coatings, or color selection.

2. References
Applicable parts of the following Practice and industry codes and standards shall be considered
an integral part of this Practice. The edition in effect on the date of contract award shall be used,
except as otherwise noted. Short titles are used herein where appropriate.

2.1 Process Industry Practices (PIP)


– PIP CTSE1000 - Application of External Coatings
2.2 Industry Codes and Standards

 American National Standards Institute (ANSI)


– ANSI Z535.1 - Safety Colors
 NACE International
– NACE Standard SP0198-2017 - Control of Corrosion under Thermal Insulation
and Fireproofing Materials - A Systems Approach
– NACE 96 Paper No. 477 - Updated Protective Coating Costs, Products and
Service Life. Gordon H. Brevoort, Kirk R. Shields, and Michael F MeLampy

3. Definitions
moderate environment: Industrial and chemical plant area subject to moderate external corrosion

offshore environment: Facilities and structures built in and above seawater

severe environment: Heavy industrial and chemical plant area subject to aggressive external
corrosion

severe/seacoast environment: Within five miles of coast/sea water and in the presence of heavy
industrial plants subject to aggressive external corrosion

4. Requirements
4.1 Coating materials shall be in accordance with this Practice.
4.2 Unless otherwise approved by the owner, coating materials used in the same system shall
be provided by the same coating manufacturer.
4.3 Unless otherwise approved by the owner, coating systems shall be selected in accordance
with the Selection Criteria Sheets, PIP CTCE1000-D011 through CTCE1000-D025.

Process Industry Practices Page 3 of 4


PIP CTCE1000 TECHNICAL REVISION
External Coating System Selection Criteria August 2018

4.4 Surface preparation, application, and inspection of external coatings shall be in


accordance with PIP CTSE1000 (Application of External Coatings) and the referenced
PIP CTSE1000 external coating system data sheets.
4.5 Coating systems listed in the selection criteria for uninsulated substrates operating at
temperatures less than 200F (93C) are selected for a minimum of 10 years service life
before 3% to 5% breakdown of the topcoat and active rusting begins in accordance with
NACE 96 Paper No. 477.
4.6 Coating systems listed in the selection criteria for insulated substrates shall be selected in
accordance with NACE Standard SP0198-2017.
4.7 Safety colors shall be defined by owner. Color standards and tolerances shall comply
with ANSI Z535.1.
4.8 If specified by the owner, coated fasteners shall be used.

Process Industry Practices Page 4 of 4


ASSOC. PIP: DOCUMENTATION
PIP CTCE1000-D001
CTCE1000 REQUIREMENTS

EXTERNAL COATING SYSTEM PAGE 1 OF 2


SELECTION CRITERIA AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PIP DOC NUMBER/ TITLE REV DATE NOTES


PROJ DOC NUMBER
CTCE1000 YES NO EXTERNAL COATING SYSTEM SELECTION
CRITERIA
CTCE1000-D001 YES NO DOCUMENTATION REQUIREMENTS

CTCE1000-D002 YES NO COATING TYPE CODE DEFINITIONS

CTCE1000-D011 YES NO SEVERE ENVIRONMENT SELECTION


CRITERIA (US CUSTOMARY UNITS)
CTCE1000-D011M YES NO SEVERE ENVIRONMENT SELECTION
CRITERIA
CTCE1000-D012 YES NO SEVERE/SEACOAST ENVIRONMENT
SELECTION CRITERIA (US CUSTOMARY
UNITS)
CTCE1000-D012M YES NO SEVERE/SEACOAST ENVIRONMENT
SELECTION CRITERIA (SI UNITS)
CTCE1000-D013 YES NO OFFSHORE ENVIRONMENT SELECTION
CRITERIA (US CUSTOMARY UNITS)
CTCE1000-D013M YES NO OFFSHORE ENVIRONMENT SELECTION
CRITERIA (SI UNITS)
CTCE1000-D014 YES NO MODERATE ENVIRONMENT SELECTION
CRITERIA (US CUSTOMARY UNITS)
CTCE1000-D014M YES NO MODERATE ENVIRONMENT SELECTION
CRITERIA (SI UNITS)
CTCE1000-D021 YES NO SEVERE ENVIRONMENT SELECTION
CRITERIA PURCHASER DEFINED (US
CUSTOMARY UNITS)
CTCE1000-D021M YES NO SEVERE ENVIRONMENT SELECTION
CRITERIA PURCHASER DEFINED (SI UNITS)
CTCE1000-D022 YES NO SEVERE/SEACOAST ENVIRONMENT
SELECTION CRITERIA PURCHASER
DEFINED (US CUSTOMARY UNITS)
CTCE1000-D022M YES NO SEVERE/SEACOAST ENVIRONMENT
SELECTION CRITERIA PURCHASER
DEFINED (SI UNITS)
CTCE1000-D023 YES NO OFFSHORE ENVIRONMENT SELECTION
CRITERIA PURCHASER DEFINED (US
CUSTOMARY UNITS)
CTCE1000-D023M YES NO OFFSHORE ENVIRONMENT SELECTION
CRITERIA PURCHASER DEFINED (SI UNITS)
ASSOC. PIP: DOCUMENTATION
PIP CTCE1000-D001
CTCE1000 REQUIREMENTS

EXTERNAL COATING SYSTEM PAGE 2 OF 2


SELECTION CRITERIA AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PIP DOC NUMBER/ TITLE REV DATE NOTES


PROJ DOC NUMBER
CTCE1000-D024 YES NO MODERATE ENVIRONMENT SELECTION
CRITERIA PURCHASER DEFINED (US
CUSTOMARY UNITS)
CTCE1000-D024M YES NO MODERATE ENVIRONMENT SELECTION
CRITERIA PURCHASER DEFINED (SI UNITS)
CTCE1000-D025 YES NO PURCHASER DEFINED ENVIRONMENT
SELECTION CRITERIA (US CUSTOMARY
UNITS)
CTCE1000-D025M YES NO PURCHASER DEFINED ENVIRONMENT
SELECTION CRITERIA (SI UNITS)
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
NOTES:
ASSOC. PIP:
TYPE CODE DEFINITIONS PIP CTCE1000-D002
CTCE1000

EXTERNAL COATING SYSTEM PAGE 1 OF 1


SELECTION CRITERIA AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

GENERIC DESCRIPTION TYPE CODE NOTES


COAL TAR EPOXY TE
EPOXY COATING EC
EPOXY MASTIC EM
EPOXY NOVOLAC EN
EPOXY PHENOLIC EP
HEAT CURED SILICONE HS
HIGH BUILD EPOXY EH
INORGANIC ZINC IZ
LOW TEMPERATURE CURE EPOXY EL
OIL BASED ALKYD OA
ORGANIC ZINC OZ
POLYSILOXANE PX
SILICONE ACRYLIC SA
URETHANE UR
WATER BORNE ACRYLIC WA
THERMAL SPRAY ALUMINUM TSA
INORGANIC COPOLYMER IC

NOTES:
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D011
CTCE1000

SEVERE ENVIRONMENT SELECTION CRITERIA PAGE 1 OF 3


(US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 200 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 200 18 CTSE1000-D118 EM/EM/UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
2.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA
350
2.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
2.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
2.1.5 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN PROPRIETARY
350 FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
2.1.6 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤1200°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED ALL NO COATING
2.2.2 (BLANK)
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D011
CTCE1000

SEVERE ENVIRONMENT SELECTION CRITERIA PAGE 2 OF 3


(US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
2.2.3 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN PROPRIETARY
350 FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
2.2.4 INSULATED <-50 NO COATING
>350
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤1200°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
3.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA
350
3.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
3.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
3.1.5 INSULATED -50 19 CTSE1000-D119 EN/EN
350
3.1.6 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤1200°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED ALL NO COATING
3.2.2
3.2.3 INSULATED -50 28 CTSE1000-D129 EN
350
3.2.4 INSULATED <-50 NO COATING
>350
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤1200°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
8.1.2 INSULATED -50 19 CTSE1000-D119 EN/EN
350
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D011
CTCE1000

SEVERE ENVIRONMENT SELECTION CRITERIA PAGE 3 OF 3


(US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
8.1.3 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
8.1.4 FIREPROOFED SUPPORTS ≤350 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
8.2 STAINLESS STEEL
8.2.1 UNINSULATED 300 4 CTSE1000-D104 EP
8.2.2 UNINSULATED >300 NO COATING
8.2.3 INSULATED -50 28 CTSE1000-D129 EN
350
8.2.4 INSULATED <-50 NO COATING
>350
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 350 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 350 14 CTSE1000-D114 IZ/HS/HS
750
9.3 INSULATED 350 19 CTSE1000-D119 EN/EN
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D011M

SEVERE ENVIRONMENT PAGE 1 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 100 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 100 18 CTSE1000-D118 EM/EM/UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
2.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA
177
2.1.3 UNINSULATED >177 14 CTSE1000-D114 IZ/HS/HS
400
2.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
2.1.5 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.1.6 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤650°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED ALL NO COATING
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.2.4 INSULATED <-46 NO COATING
>177
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D011M

SEVERE ENVIRONMENT PAGE 2 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
3.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA
177
3.1.3 UNINSULATED >177 14 CTSE1000-D114 IZ/HS/HS
400
3.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
3.1.5 INSULATED -46 19 CTSE1000-D119 EN/EN
177
3.1.6 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED ALL NO COATING
3.2.2
3.2.3 INSULATED -46 28 CTSE1000-D129 EN
177
3.2.4 INSULATED <-46 NO COATING
>177
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
8.1.2 INSULATED -46 19 CTSE1000-D119 EN/EN
177
8.1.3 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
8.1.4 FIREPROOFED SUPPORTS ≤177 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D011M

SEVERE ENVIRONMENT PAGE 3 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
8.2 STAINLESS STEEL
8.2.1 UNINSULATED 150 4 CTSE1000-D104 EP
8.2.2 UNINSULATED >150 NO COATING
8.2.3 INSULATED -46 28 CTSE1000-D129 EN
177
8.2.4 INSULATED <-46 NO COATING
>177
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 177 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 177 14 CTSE1000-D114 IZ/HS/HS
400
9.3 INSULATED <177 19 CTSE1000-D119 EN/EN
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D012

SEVERE/SEACOAST ENVIRONMENT PAGE 1 OF 3


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 200 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 200 18 CTSE1000-D118 EM/EM/UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
2.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA
350
2.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
2.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
2.1.5 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN
350
2.1.6 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤1200°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED 300 4 CTSE1000-D104 EP
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN
350
2.2.4 INSULATED <-50 NO COATING
>350
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D012

SEVERE/SEACOAST ENVIRONMENT PAGE 2 OF 3


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC *NORMAL
OPERATION ≤1200°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
3.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA
350
3.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
3.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
3.1.5 INSULATED -50 19 CTSE1000-D119 EN/EN
350
3.1.6 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤1200°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED 300 4 CTSE1000-D104 EP
3.2.2 UNINSULATED >300 NO COATING
3.2.3 INSULATED -50 28 CTSE1000-D129 EN
350
3.2.4 INSULATED <-50 NO COATING
>350
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC *NORMAL
OPERATION ≤1200°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
8.1.2 INSULATED -50 19 CTSE1000-D119 EN/EN
350
8.1.3 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D012

SEVERE/SEACOAST ENVIRONMENT PAGE 3 OF 3


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
8.1.4 FIREPROOFED SUPPORTS ≤350 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
8.2 STAINLESS STEEL
8.2.1 UNINSULATED 300 4 CTSE1000-D104 EP
8.2.2 UNINSULATED >300 NO COATING
8.2.3 INSULATED -50 28 CTSE1000-D129 EN
350
8.2.4 INSULATED <-50 NO COATING
>350
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 350 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 350 14 CTSE1000-D114 IZ/HS/HS
750
9.3 INSULATED 350 19 CTSE1000-D119 EN/EN
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D012M

SEVERE/SEACOAST ENVIRONMENT PAGE 1 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 100 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 100 18 CTSE1000-D118 EM/EM/UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
2.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA
177
2.1.3 UNINSULATED >177 14 CTSE1000-D114 IZ/HS/HS
400
2.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
2.1.5 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.1.6 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤650°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED 150 4 CTSE1000-D104 EP
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.2.4 INSULATED <-46 NO COATING
>177
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D012M

SEVERE/SEACOAST ENVIRONMENT PAGE 2 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
3.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA
177
3.1.3 UNINSULATED >177 14 CTSE1000-D114 IZ/HS/HS
400
3.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
3.1.5 INSULATED -46 19 CTSE1000-D119 EN.EN
177
3.1.6 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED 150 4 CTSE1000-D104 EP
3.2.2 UNINSULATED >150 NO COATING
3.2.3 INSULATED -46 4 CTSE1000-D129 EN
177
3.2.4 INSULATED <-46 NO COATING
>177
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
8.1.2 INSULATED -46 19 CTSE1000-D119 EN/EN
177
8.1.3 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D012M

SEVERE/SEACOAST ENVIRONMENT PAGE 3 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
8.1.4 FIREPROOFED SUPPORTS ≤177 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
8.2 STAINLESS STEEL
8.2.1 UNINSULATED 150 4 CTSE1000-D104 EP
8.2.2 UNINSULATED >150 NO COATING
8.2.3 INSULATED -46 28 CTSE1000-D129 EN
177
8.2.4 INSULATED <-46 NO COATING
>177
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 177 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 177 14 CTSE1000-D114 IZ/HS/HS
400
9.3 INSULATED 177 19 CTSE1000-D119 EN/EN
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D013
CTCE1000

OFFSHORE ENVIRONMENT SELECTION PAGE 1 OF 3


CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 200 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 200 18 CTSE1000-D118 EM/EM/UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
2.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA
350
2.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
2.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
2.1.5 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN
350
2.1.6 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤1200°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED ALL NO COATING
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN
350
2.2.4 INSULATED <-50 NO COATING
>350
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D013
CTCE1000

OFFSHORE ENVIRONMENT SELECTION PAGE 2 OF 3


CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC *NORMAL
OPERATION ≤1200°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
3.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA
350
3.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
3.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
3.1.5 INSULATED -50 19 CTSE1000-D119 EN/EN
350
3.1.6 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤1200°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED ALL NO COATING
3.2.2
3.2.3 INSULATED -50 28 CTSE1000-D129 EN
350
3.2.4 INSULATED <-50 NO COATING
>350
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC *NORMAL
OPERATION ≤1200°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 200 15 CTSE1000-D115 IZ/EM/UR
8.1.2 INSULATED -50 19 CTSE1000-D119 EN/EN
350
8.1.3 INSULATED <-50 NO COATING COATING SYSTEM 1
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
8.1.4 FIREPROOFED SUPPORTS ≤350 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D013
CTCE1000

OFFSHORE ENVIRONMENT SELECTION PAGE 3 OF 3


CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
8.2 STAINLESS STEEL
8.2.1 UNINSULATED 300 4 CTSE1000-D104 EP
8.2.2 UNINSULATED >300 NO COATING
8.2.3 INSULATED -50 28 CTSE1000-D128 EN
350
8.2.4 INSULATED <-50 NO COATING
>350
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 350 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 350 14 CTSE1000-D114 IZ/HS/HS
750
9.3 INSULATED 350 19 CTSE1000-D119 EP/EP

10.0 MISCELLANEOUS - CARBON STEEL


10.1 SPLASH ZONE AMBIENT 25 CTSE1000-D125 EH/EH/UR
10.2 HELIPORT AMBIENT 25 CTSE1000-D125 EH/EH/UR
10.3 DECK PLATE – WALKING SURFACES AMBIENT 25 CTSE1000-D125 EH/EH/UR
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D013M

OFFSHORE ENVIRONMENT PAGE 1 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 100 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 100 18 CTSE1000-D118 EM/EM/UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
2.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA
177
2.1.3 UNINSULATED >100 14 CTSE1000-D114 IZ/HS/HS
400
2.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
2.1.5 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.1.6 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤650°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED ALL NO COATING
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.2.4 INSULATED <-46 NO COATING
>177
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D013M

OFFSHORE ENVIRONMENT PAGE 2 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
3.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA
177
3.1.3 UNINSULATED >177 14 CTSE1000-D114 IZ/HS/HS
400
3.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
3.1.5 INSULATED -46 19 CTSE1000-D119 EN/EN
177
3.1.6 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED ALL NO COATING
3.2.2
3.2.3 INSULATED -46 28 CTSE1000-D129 EN
177
3.2.4 INSULATED <-46 NO COATING
>177
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 100 15 CTSE1000-D115 IZ/EM/UR
8.1.2 INSULATED -46 19 CTSE1000-D119 EN/EN
177
8.1.3 INSULATED <-46 NO COATING COATING SYSTEM 1
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D013M

OFFSHORE ENVIRONMENT PAGE 3 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
8.1.4 FIREPROOFED SUPPORTS ≤177 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
8.2 STAINLESS STEEL
8.2.1 UNINSULATED 150 4 CTSE1000-D104 EP
8.2.2 UNINSULATED >150 NO COATING
8.2.3 INSULATED -46 28 CTSE1000-D129 EN
177
8.2.4 INSULATED <-46 NO COATING
>177
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 177 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 177 14 CTSE1000-D114 IZ/HS/HS
400
9.3 INSULATED 177 19 CTSE1000-D119 EN/EN

10.0 MISCELLANEOUS - CARBON STEEL


10.1 SPLASH ZONE AMBIENT 25 CTSE1000-D125 EH/EH/UR
10.2 HELIPORT AMBIENT 25 CTSE1000-D125 EH/EH/UR
10.3 DECK PLATE – WALKING SURFACES AMBIENT 25 CTSE1000-D125 EH/EH/UR
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D014
CTCE1000

MODERATE ENVIRONMENT SELECTION PAGE 1 OF 3


CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 200 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 200 24 CTSE1000-D124 EM//UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 200 24 CTSE1000-D124 EM/UR
2.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA
350
2.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
2.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
2.1.5 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN
350
2.1.6 INSULATED <-50 NO COATING COATING SYSTEM
>350 24 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤1200°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED ALL NO COATING
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED -50 19 CTSE1000-D119 EN/EN
350
2.2.4 INSULATED <-50 NO COATING
>350
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D014
CTCE1000

MODERATE ENVIRONMENT SELECTION PAGE 2 OF 3


CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC *NORMAL
OPERATION ≤1200°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 200 24 CTSE1000-D124 EM/UR

3.1.2 UNINSULATED >200 10 CTSE1000-D110 IZ/SA/SA


350
3.1.3 UNINSULATED >350 14 CTSE1000-D114 IZ/HS/HS
750
3.1.4 UNINSULATED >750 12 CTSE1000-D112 HS/HS
1200
3.1.5 INSULATED -50 19 CTSE1000-D119 EN/EN
350
3.1.6 INSULATED <-50 NO COATING COATING SYSTEM 24
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤1200°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED ALL NO COATING
3.2.2
3.2.3 INSULATED -50 28 CTSE1000-D129 EN
350
3.2.4 INSULATED <-50 NO COATING
>350
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC *NORMAL
OPERATION ≤1200°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 200 8 CTSE1000-D108 IZ/WA
8.1.2 INSULATED -50 19 CTSE1000-D119 EN/EN
350
8.1.3 INSULATED <-50 NO COATING COATING SYSTEM 8
>350 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D014
CTCE1000

MODERATE ENVIRONMENT SELECTION PAGE 3 OF 3


CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
8.1.4 FIREPROOFED SUPPORTS ≤350 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
8.2 STAINLESS STEEL
8.2.1 UNINSULATED ALL NO COATING
8.2.2 UNINSULATED
8.2.3 INSULATED -50 28 CTSE1000-D129 EN
350
8.2.4 INSULATED <-50 NO COATING
>350
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 350 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 350 14 CTSE1000-D114 IZ/HS/HS
750
9.3 INSULATED 350 19 CTSE1000-D119 EN/EN
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D014M

MODERATE ENVIRONMENT PAGE 1 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS, GALVANIZED
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES, 100 24 CTSE1000-D124 EM/UR FOR COLOR ONLY
PLATFORMS, STAIRWAYS, AS REQUIRED
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS 100 24 CTSE1000-D124 EM//UR
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE 20 CTSE1000-D120 EP/EP
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE (SEE REMARKS) (SEE REMARKS) PROPRIETARY
FIREPROOFED WITH INTUMESCENT FIREPROOFING
MATERIAL PRIMER DEFINED
BY SUPPLIER
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED 100 24 CTSE1000-D124 EM/UR
2.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA
177
2.1.3 UNINSULATED >177 14 CTSE1000-D114 IZ/HS/HS
400
2.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
2.1.5 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.1.6 INSULATED <-46 NO COATING COATING SYSTEM
>177 24 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
2.1.7 INSULATED CYCLIC* 30 CTSE100-D130 IC/IC * NORMAL
OPERATION ≤650°
2.2 STAINLESS STEEL
2.2.1 UNINSULATED ALL NO COATING
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED -46 19 CTSE1000-D119 EN/EN
177
2.2.4 INSULATED <-46 NO COATING
>177
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D014M

MODERATE ENVIRONMENT PAGE 2 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
2.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED 100 24 CTSE1000-D124 EM/UR

3.1.2 UNINSULATED >100 10 CTSE1000-D110 IZ/SA/SA


177
3.1.3 UNINSULATED >177 14 CTSE1000-D114 IZ/HS/HS
400
3.1.4 UNINSULATED >400 12 CTSE1000-D112 HS/HS
650
3.1.5 INSULATED -46 19 CTSE1000-D119 EN/EN
177
3.1.6 INSULATED <-46 NO COATING COATING SYSTEM 24
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
3.1.7 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
3.2 STAINLESS STEEL
3.2.1 UNINSULATED ALL NO COATING
3.2.2
3.2.3 INSULATED -46 28 CTSE1000-D129 EN
177
3.2.4 INSULATED <-46 NO COATING
>177
3.2.5 INSULATED CYCLIC* 30 CTSE1000-D130 IC/IC * NORMAL
OPERATION ≤650°
4.0 PUMPS, COMPRESSORS, AND ALL MANUFACTURER’S
ROTATING EQUIPMENT STANDARD
5.0 BULK VALVES AND FITTINGS ALL MANUFACTURER’S
STANDARD
6.0 ELECTRIC MOTORS AND EQUIPMENT ALL MANUFACTURER’S
STANDARD
7.0 INSTRUMENTS AND CONTROL ALL MANUFACTURER’S
PANELS STANDARD
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED 100 8 CTSE1000-D108 IZ/WA
8.1.2 INSULATED -46 19 CTSE1000-D119 EN/EN
177
8.1.3 INSULATED <-46 NO COATING COATING SYSTEM 8
>177 REQUIRED ONLY
FOR UNINSULATED
COMPONENTS
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D014M

MODERATE ENVIRONMENT PAGE 3 OF 3


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
8.1.4 FIREPROOFED SUPPORTS ≤177 19 CTSE1000-D119 EN/EN PROPRIETARY
FIREPROOFING
PRIMER DEFINED
BY SUPPLIER
8.2 STAINLESS STEEL
8.2.1 UNINSULATED ALL NO COATING
8.2.2 UNINSULATED
8.2.3 INSULATED -46 28 CTSE1000-D129 EN
177
8.2.4 INSULATED <-46 NO COATING
>177
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED 177 10 CTSE1000-D110 IZ/SA/SA
9.2 UNINSULATED 177 14 CTSE1000-D114 IZ/HS/HS
400
9.3 INSULATED 177 19 CTSE1000-D119 EN/EN
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D021
CTCE1000

SEVERE ENVIRONMENT SELECTION CRITERIA PAGE 1 OF 2


(US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D021
CTCE1000

SEVERE ENVIRONMENT SELECTION CRITERIA PAGE 2 OF 2


(US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D021M

SEVERE ENVIRONMENT SELECTION CRITERIA PAGE 1 OF 2


(SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D021M

SEVERE ENVIRONMENT SELECTION CRITERIA PAGE 2 OF 2


(SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D022
CTCE1000

SEVERE/SEACOAST ENVIRONMENT PAGE 1 OF 2


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D022
CTCE1000

SEVERE/SEACOAST ENVIRONMENT PAGE 2 OF 2


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2 UNINSULATED
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D022M

SEVERE/SEACOAST ENVIRONMENT PAGE 1 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D022M

SEVERE/SEACOAST ENVIRONMENT PAGE 2 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2 UNINSULATED
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D023
CTCE1000

OFFSHORE ENVIRONMENT PAGE 1 OF 2


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D023
CTCE1000

OFFSHORE ENVIRONMENT PAGE 2 OF 2


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
10.0 MISCELLANEOUS - CARBON STEEL
10.1 SPLASH ZONE
10.2 HELIPORT
10.3 DECK PLATE – WALKING SURFACES
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D023M

OFFSHORE ENVIRONMENT PAGE 1 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D023M

OFFSHORE ENVIRONMENT PAGE 2 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
10.0 MISCELLANEOUS - CARBON STEEL
10.1 SPLASH ZONE
10.2 HELIPORT
10.3 DECK PLATE – WALKING SURFACES
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D024
CTCE1000

MODERATE ENVIRONMENT PAGE 1 OF 2


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D024
CTCE1000

MODERATE ENVIRONMENT PAGE 2 OF 2


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D24M
CTCE1000

MODERATE ENVIRONMENT PAGE 1 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2 (BLANK)
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D24M
CTCE1000

MODERATE ENVIRONMENT PAGE 2 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D025
CTCE1000

PURCHASER DEFINED ENVIRONMENT PAGE 1 OF 3


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

ENVIRONMENT DEFINITION:

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
1.6
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP
FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.1.8
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
2.2.6
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D025
CTCE1000

PURCHASER DEFINED ENVIRONMENT PAGE 2 OF 3


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

ENVIRONMENT DEFINITION:

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
3.1.8
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
3.2.6
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND
EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
ASSOC. PIP:
SELECTION CRITERIA SHEET PIP CTCE1000-D025
CTCE1000

PURCHASER DEFINED ENVIRONMENT PAGE 3 OF 3


SELECTION CRITERIA (US CUSTOMARY UNITS) AUGUST 2018

ENVIRONMENT DEFINITION:

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °F NO. DATA SHEET
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D025M

PURCHASER DEFINED ENVIRONMENT PAGE 1 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

NO. DATE REVISION DESCRIPTION BY CHECKED APPROVED

ENVIRONMENT DEFINITION:

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
1.0 STRUCTURAL STEEL
1.1 EXTERIOR COLUMNS, BEAMS,
GIRDERS, TRUSSES, CHANNELS,
WALKWAYS, HANDRAILS, LADDERS,
GRATING AND OTHER STRUCTURAL
MEMBERS
1.2 GALVANIZED LADDERS, CAGES,
PLATFORMS, STAIRWAYS,
WALKWAYS, AND HANDRAIL
ASSEMBLIES
1.3 EXTERIOR MISCELLANEOUS
UNGALVANIZED FIELD FABRICATED
STEEL
1.4 STRUCTURAL STEEL TO BE
FIREPROOFED WITH CEMENTITIOUS
MATERIAL
1.5 STRUCTURAL STEEL TO BE
FIREPROOFED WITH INTUMESCENT
MATERIAL
1.6
2.0 TANKS, DRUMS, COLUMNS, VESSELS, REACTORS, AND SHELL AND TUBE HEAT EXCHANGERS, SHOP
FABRICATED
2.1 CARBON STEEL
2.1.1 UNINSULATED
2.1.2 UNINSULATED
2.1.3 UNINSULATED
2.1.4 UNINSULATED
2.1.5 INSULATED OR FIREPROOFED
2.1.6 INSULATED
2.1.7 INSULATED
2.1.8
2.2 STAINLESS STEEL
2.2.1 UNINSULATED
2.2.2
2.2.3 INSULATED OR FIREPROOFED
2.2.4 INSULATED
2.2.5 INSULATED
2.2.6
ASSOC. PIP: PIP CTCE1000-
SELECTION CRITERIA SHEET
CTCE1000 D025M

PURCHASER DEFINED ENVIRONMENT PAGE 2 OF 2


SELECTION CRITERIA (SI UNITS) AUGUST 2018

ENVIRONMENT DEFINITION:

PROJECT NO. PROJECT DOCUMENT NO.


FACILITY NAME
LOCATION

PARA. ITEMS OPER. COATING SYSTEM TYPE CODES REMARKS


NO. TEMP., °C NO. DATA SHEET
3.0 PIPE, FABRICATED PIPE SPOOLS, TO INCLUDE ATTACHED VALVES, PIPE SUPPORTS
3.1 CARBON STEEL
3.1.1 UNINSULATED
3.1.2 UNINSULATED
3.1.3 UNINSULATED
3.1.4 UNINSULATED
3.1.5 INSULATED
3.1.6 INSULATED
3.1.7 INSULATED
3.1.8
3.2 STAINLESS STEEL
3.2.1 UNINSULATED
3.2.2
3.2.3 INSULATED
3.2.4 INSULATED
3.2.5 INSULATED
3.2.6
4.0 PUMPS, COMPRESSORS, AND
ROTATING EQUIPMENT
5.0 BULK VALVES AND FITTINGS
6.0 ELECTRIC MOTORS AND
EQUIPMENT
7.0 INSTRUMENTS AND CONTROL
PANELS
8.0 TANKS AND SPHERES, FIELD ERECTED
8.1 CARBON STEEL
8.1.1 UNINSULATED
8.1.2 INSULATED
8.1.3 INSULATED
8.1.4 FIREPROOFED SUPPORTS
8.2 STAINLESS STEEL
8.2.1 UNINSULATED
8.2.2 UNINSULATED
8.2.3 INSULATED
8.2.4 INSULATED
9.0 FURNACES, STACKS, BREECHINGS, DUCTS, AND BOILERS
9.1 UNINSULATED
9.2 UNINSULATED
9.3 INSULATED