Professional Documents
Culture Documents
Indirekt Waterbath-Heater: Type VH
Indirekt Waterbath-Heater: Type VH
Indirekt Waterbath-Heater: Type VH
WATERBATH-HEATER
TYPE VH
adequate for all gases acc. to “DVGW Arbeitsblatt” (work sheet) G260
and for all non-aggressive special gases
» Decentralized application Indirect water bath heaters type VH The water shell is designed
» Optimal load case design are heat exchangers (heat atmospherically by default and is
» Stream-optimized design exchangers) which can heat the gas provided with a dome as a water-
» Vibration-optimized design decentrally if no hot water treatment side expansion volume. At the same
(for example, a boiler system) is time, the dome serves as an
OPTIONS FOR HP-TUBE-BUNDLE available. inspection opening for the visual
The heating of the gas is necessary inspection of the tube bundles.
» Customer-specific design codes in order to counteract the Joule-
e.g. ASME, EN 13445, SVTI, AS1210 Thomson effect during pressure NATURAL GAS PRE-HEATING
PD5500, etc. reduction or to provide a defined gas
» Design according to TEMA temperature for the following system The gas-transporting HP-tube
» Customer-specific acceptance test components. bundle is located above the burner
» Customer-specific testings The most common applications are: chamber in the water bath. The
» Application for sour gas (NACE) Probes of gas fields, pipeline: to preheated water warms the gas. The
» Design for low temperature up to -50 ° C GDRM and compressor stations, HP-tube bundle consists of the
» Design pressure up to 300 bar cavern storage, power stations external gas inlet and outlet
» Customer-specific nozzle arrangement chamber with the corresponding
» Water shell design as pressure vessel The design is carried out as a steel- nozzles, as well as the internal heat
» Water tank for hot water> 100 ° C welded construction in a horizontal transfer tubes.
design.
BURNER
FUNCTION
ACCESSORIES ON DEMAND
The firing is carried out by the use of
An indirect water bath heater is a
» Gas-temperature control with bypass a gas fan burner. These are used
actuator combined heat exchanger equipped because of their excellent
» Temperature monitoring with with a (HD) high-pressure tube combustion values at high emission
bundle (natural gas pre-heating) and
remote transmission requirements.
» BUS / Ethernet connection a burner firing unit (water pre-
» Protective cabinet for pressure reduction heating). The two sections are
strictly separated from one another
» Steel construction, operating platform, FUEL GAS PRESSURE
ladder, etc. for safety reasons. The natural
circulation of the water (natural REDUCTION
QUALITY MANAGEMENT convection) results from the
combustion unit arranged at the By default, a pressure reduction is
» DIN EN ISO 9001 certified bottom and the above HD bundle. provided for the combustion gas.
"Our apparatuses are according to This is carried out in one or two
AD 2000 regulations and CE-certified stages for corresponding operating
according to EC / PED 2014/68 / EU. WATER-PRE-HEATING data and is equipped with safety
The examination is carried out by shut-off valves (SAV) based thereon.
authorized third party experts (TÜV, etc.) In the combustion unit, water is A safety blow-off valve (SBV) is
»Test and material are prepared by the heated by combustion energy. For provided after each pressure
experts according to the design this purpose, fuel gas is fired from reduction stage.
specification. the main gas stream for firing. The
»The burner control is based on the safety unit consists of a flame pipe, the
concept according to DIN EN 746-2. REGULATION
return chamber and the recirculating
smoke gas pipes. The flue gas
The complete heater unit is
PROCESS CALCULATIONS collecting chamber is provided with
monitored with an electrical /
a chimney that can be dismantled
electronic control system suitable for
Our heat exchanger calculations are for transportation reasons. The
the gas blower burner and can be
based on the theoretical foundations of combustion unit contains a sound-
coupled to the higher-level control
‘VDI Wärmeatlas’ and the HEDH (Heat insulated enclosure. The combustion
system.
Exchanger Design Book). efficiency is approx. 92%.
Design Daten:
Bit t e angeben
Auslegungsvorschrift AD 2000 ASME TEMA
Bit t e angeben
Tests / Optionen CE / PED U-Stamp NACE
Auslegungsdruck PN bar Korrosionszuschlag c 2 mm
Auslegungstemperatur DT - /+ °C Ausführung: horizontal
Berechnungsdaten: in den Rohren Mantelseite
Medium Erdgas Bit t e angeben
Medium x Wasser
Dichte (Gasanalyse) ρ ni kg/m³ Dichte ρ na 998,3 kg/m³
Volumenstrom Vi Nm³/h / SCFM Designdruck 0 bar
Eintrittsdruck Pi bar Prüfdruck 0,5 bar
Austrittsdruck n.d.R Pad bar
Eintrittstemperatur ϑ ei °C
Austrittstemperatur n.d.R. ϑ ad °C
Berechnungswert
Wärmeleistung Q kW
Rohrbündel ziehbar ja nein
P&ID:
In process
Email info@gts-thielmann.de
www.gts-thielmann.de
edition 05/17