/ I/O BOARD 84353 WIRING SCHEMATIC rev J

Note: Board revision identification is indicated in a white box near the center of the board. PRINTER (RS-232) ETVC
If no rev is indicated, the board is rev E and the Rev E wire wiring diagram should be referenced. (Electronic Temperature Volume Compensation)

MH1
MH6
RTS/Red (92) 71130 Temperature Probe
J310 TXD/Violet (91) White (00)
RTS/Brown (84)

00

TEMPERATURE PROBE
TXD/Orange (83) RXD/Gray (90) White (99)

99
FID2
RXD/Yellow (82) CTS/Green (89) Red (98)

98
GND/White (88)
CTS/Blue (81) Red (97)
H301
Black Data J15

97
Cable 40’ GND/Black (80) ANA+ (96)
H303 J311 Power

96
C207 4 - 20 mA
Supply
79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 Loop ANA- (95)

95
J307
RS232/RS485 J13 RS232/RS485 J14
J1 PORT 0 PORT 1
J1 PRINTER
POWER CAN SERIAL BUS
DISPLAY

C208 DC POWER IN J13 J14

H306
825001
Printer Power Cable Open
EARTH EARTH/Shield (1) Drain

DC POWER IN J1

1
BATTERY GND/Black (2)

EARTH/SHIELD (43)
GND
J301

2
N

CAN-H (46)
CAN-L (45)
+12-24/Red (3)

GND (44)
JX1

3
+VBATT
DIFFERENTIAL

3
SD CARD Y

4
J308 PRESSURE (∆P)
F1 ACC

4
J31 TRANSDUCER
H1 JTAG USB FS OTG J2 J1

D-IN-7/SNSR
J2 40' Gray
Power
ACC J8

D-IN-7/SNSR
Cable

EARTH
+VP/Black (12)

EARTH
ACC Open

EARTH
GND

EARTH
+VP
+VP

+VP
Drain
485-B3/Yellow (38)

GND
S3

+VP
S4

+VP

+VP
43 44 45 46
J306

S3
S4
Power
USB HOST 10 11 12 13 14 15 16 17 18 485-A3/Blue (37) 10 11 12 13 14 15 16 17 18 In-line Power
Supply GROUND
H7 Supply
R163 GND/White (36)
84512 Power Cable, 40’ Fuse Battery or DC
TX
Accessory Panel
JSW RX HIGH SPEED CAN BUS
R155

RTS J2 SOLENOID OUTPUTS - S3 & S4

JSW GND 82637


J7 J2 SOLENOID OUTPUTS - S3 & S4

EA
EA
∆P Transducer Kit

48
CALIBRATION

48
EA

RT
GN

5-

RT

+V
5-

+V
RT

B-

S2

S1
H
SWITCH

A-

P
H
D

P
4
H

4
19 20 21 22 23 24

EA
39 40 41 42
BACKLIGHT

EA
48

MH2
J302

48

48
EA

J3

48
EA
RT
GN

5-

GN

5-
RT

+V

5-
5-

AUXILIARY DEVICE

+V

RT
J6
RT

B-
B-

S2

S1

A-
H

D
A-

P
H

3
D

3
P
4
H

19 20 21 22 23 24 35 36 37 38
39 40 41 42 MH2
48
48

48
EA

J6
48
EA

J7 RS-485 PORT 4 J3 SOLENOID OUTPUTS - S1 & S2 S1


GN

5-
GN

5-

5-
5-

RT

I/O EXPANSION
B-
RT

Auxiliary
B-

A-

PULSE OUTPUT
A-

D
D

3
H

+VP
2
H

3
2

Device
31 32 33 34 35 36 37 38 J6 RS-485 PORT 3
DEVICE (POD) 1-4
J5
J7 RS-485 PORT 4 J3 SOLENOID OUTPUTS - S1 & S2 19 20 21 22 23 24 i.e Dead-Man
MH5 I/O EXPANSION Shutdown
ASSEMBLY: 84353

J9 J3
OPTICAL AIR AND
D-OUT-6

J5 RS-485 PORT 2 J6 RS-485 PORT 3


D-OUT-4

D-OUT-3
D-OUT-5

D-OUT-2

D-OUT-1 S3/Black (17)


VAPOR ELIMINATORS 2
GND
CA

SOLENOID OUTPUTS - S1 & S2 J3


+VP
CA
SH

GN

MH8
N-

J30 ETHERNET
N-
LD

H
D

43 44 45 46 47 48 49 50 51 52 53 54 81947
Optical Sensor
502011
S3 Solenoid Valve S3 +VP/Red (18) 1

CHA/White (69)
GND/Black (63)
J8
REV.

CHB/Green (68)
AUXILIARY OUTPUTS

+Vo/Red (70)
J8 +VP/Red (12) S3/Black (17)
HIGH-SPEED CAN BUS Auxiliary Output 2 (Out 2)
SNSR/White (11) +VP/Red (18)
J9 DIGITAL OUTPUTS Pulse Output (Out 3)
48 1
48

Gnd/Black (10)
EA

Auxiliary Output 1
CT

RX

TX

RT

5-
GN

5-
RT

B-
D-
S-

S-
D-

A-
D

(Out 1)
1

1
H

63 66 67 68 69 70
J13 87 88 89 90 91 92 93 94 10 11 12 13 14 15 16 17 18
64 65
47 48 49 50 51 52 53 54
SOLENOID OUTPUTS - S3 & S4 J2 J9
J2 J11
J11
48 0
48
EA

CT

RX

TX

RT

5-
GN

5-

PULSE OUTPUTS J11 DIGITAL OUTPUTS J9


RT

B-
D-
S-

S-
D-

A-
D

0
0

0
H

63 64 65 66 67 68 69 70
79 80 81 82 83 84 85 86 J14 +5V DIG IN
RS-232 / J14
RS-485
PORT 1 JP SOLENOID Single Stage
2 S2 (20) S1 (23) 2

NC
VALVES or +VP (21) Earth (22)
JP J11 DIGITAL INPUTS
J13 RS-232 / RS-485
PORT 0
GND Two Stage 1
1
D-IN-6

CHB
+EXT_PLSR
GND

D-IN-4

D-IN-3

+VP (24)
D-IN-5

Earth (19)
D-IN-2-CHB

D-IN-1-CHA

PRINTER CHA

J15 +5V0_INT_PL 81527 3-Way Solenoid (LPG)


INTERNAL
AN

AN

RT

RT

RT

RT

INTERNAL PULSER PULSER


D+

D+

D-

D+
A-

A+

A2859-11 Block Valve (LPG)


S

CONNECTOR
D

MH4 MH3
95 96 97 98 99 00 J15
The Earth grounds for Terminals 19 A2848-11 Two Stage Block Valve
& 22 are optional. The solenoid +VP (21) Earth (22)
TEMPERATURE
® © 2018 operated valves are grounded A2982 E-7 Two Stage Piston Valve
through the component they are S2 (20) S1 (23)
PROBE L I Q U I D CO N T R O L S, LLC mounted on. Earth (19)

CHA/White
+VP (24)

CHB/Green
GND/Black
81527 3-Way Solenoid (LPG)

+5/Red
A2843 Block Valve (LPG) 84412
Solenoid operated valve 81527 19 20 21 22 23 24 Internal Pulser Kit
(3-way LPG solenoid) has 3 cables A2847-11
potted into the housing. All other Single Stage Block Valve J3
ESD PRECAUTION OPENING CENTRILOGiQ REGISTERS solenoid operated valves on Liquid
Before opening the CENTRILOGiQ register and handling the CPU board, it is important to discharge any ESD that may have built up on your person. To discharge ESD from your person, Controls valves use cable assembly JP
81859, which has 2 cables. SOLENOID OUTPUTS - S1 & S2 J3
touch a well-grounded point such as the CENTRILOGiQ register housing, the meter, the truck piping, or the bumper. When the maintenance is complete and the CENTRILOGiQ register
door is closed, the CPU board is protected from ESD by the CENTRILOGiQ register housing which is grounded to the chassis. INTERNAL PULSER CONNECTOR JP

Pub. No. 500449