SONOLASTIC® ULTRA

High performance polyurethane joint sealant

DESCRIPTION PERFORMANCE DATA


Sonolastic Ultra is a one component, moisture curing, Value
aliphatic polyurethane sealant. Aliphatic technology Property Test Method
(Average)
ensures Sonolastic Ultra will be UV resistant, non-
Movement capability
chalking, non-staining, self cleaning and non pick, ASTM C 719 ± 25%
(MAF)
resulting in unmatched durability.
Tensile strength ASTM D 412 4.1
RECOMMENDED FOR Ultimate elongation at
ASTM D 412 600%
break
Active, exterior and interior joints that demand extreme UV
Hardness at standard
resistance and long term colour integrity. Sonolastic Ultra ASTM C 661 50 ± 5
conditions (Shore A)
can be used on both vertical and horizontal applications
including trafficable surfaces on floors, panels, walls, Tack-free time Less than
ASTM C 679
window frames, curtain walls and precast panels. 72 hours
Substrates include concrete, masonry, brick, aluminium Stain and colour
ASTM C 510 None
and timber. change
Volatile Organic SCAQMD
Pick resistance finds applications in shop fronts, prisons, 90g/litre
Compounds (VOC) Method 304-91
schools, public amenities and buildings.
Service temperature
-40 to 82
FEATURES AND BENEFITS range (ºC)
2
• Aliphatic polyurethane technology Potable water certified AS/NZS 4020 2500m /L
Non-staining, non-yellowing, non-chalking. Note: The data represents information typically required to verify
• High UV resistance performance. For the full and comprehensive list of performance
No discolouration from sunlight data, refer to “Application Guide & Performance Data for
• Medium modulus Sonolastic Polyurethane Sealants” available from your local BASF
Excellent puncture and abrasion resistance Construction Chemicals representative.
• Improved
Improved gunability and workability ESTIMATING DATA
Easy tooling
• Pick resistant Joint Size (mm) Metres per litre
Security applications 5x5 40
• Suitable for non- non-chlorinated water immersion 10 x 10 10
situations 12 x 12 6.95
No swelling or softening 15 x 7.5 8.88
• Movement capability ±25%25% 20 x 10 5.00
Expands and contracts with joint movement 25 x 12.5 3.20
• Excellent Chemical Resistance 30 x 15 2.22
Ideal in food or petroleum environments
• No surface tackiness APPLICATION
No dirt pickup, self-cleaning For information on joint design, surface preparation and
• Approved for potable water priming,
priming refer to Technical Note 17 “Application Guide &
Performance data for Sonolastic Polyurethane Sealants”
COMPLIANCES
available from your local BASF Construction Chemicals
• Federal Specification TT-S-00230C, Type II, Class A representative.
when primed. Application
• ASTM C 920, Type S, Grade NS, Class 25. Use NT, • Sonolastic Ultra comes ready to use. Apply by
M, A, G and I. professional caulking gun. Do not open cartridges or
• Corps of engineers CRD C-541, Type II, Class A. sausages, until preparatory work has been
• USDA approved for use in meat and poultry areas. completed.
• Canadian approval for use in areas that handle food. • Fill joints from deepest point to the surface by holding
a suitably sized nozzle against the back of the joint.
• Dry tooling is recommended. DO NOT use soapy
water when tooling. Tooling results in the correct
bead shape, a neat joint, and maximum adhesion.
SONOLASTIC® ULTRA
For Best Performance COLOURS
• Do not allow uncured Sonolastic Ultra to come into
Choice of standard colours are available including white,
contact with alcohol-based materials or solvents.
aluminium-grey.
• Do not apply polyurethane sealants in the vicinity of
uncured silicone sealants or uncured Sonolastic 150 CURING
or 150 Tint Base.
Base The cure of Sonolastic Ultra varies with temperature and
• Sonolastic Ultra should not come in contact with oil- humidity. The following times assume 23°C, 50% relative
based caulking, silicone sealants, polysulfides or humidity, and a joint 12mm width by 6mm depth.
fillers impregnated with oil, asphalt or tar. • Skins - overnight or within 24 hours
• When Sonolastic Ultra is to be used in areas subject • Functional within 3 days
to water immersion, cure for 21 days at 25°C and • Full cure in approximately 1 week
50% relative humidity. Allow longer cure time at • Immersion service: 21 days
lower temperatures and humidity. Note: If joint thickness is more than 6mm, then cure
• Do not use in swimming pools or other submerged period increases.
conditions where the sealant will be exposed to CLEANING
strong oxidizers. Avoid submerged conditions where
• Immediately after use, clean equipment with
water temperatures will exceed 50°C.
Sonoshield Thinner. Use proper precautions when
• Protect unopened containers from heat and direct
handling solvents.
sunshine.
• Remove cured sealant by cutting with a sharp edge
• In cool or cold weather, store container at room
tool.
temperature for at least 24 hours before using.
• Remove thin films by abrading.
• Do not apply over freshly treated wood; treated wood
must have weathered for at least 6 months. PACKAGING
• All horizontal applications require the use of a primer. • 590ml Pro Pak sausages, 20 sausages to a carton
• Sonolastic Ultra can be applied below freezing
SHELF LIFE
temperatures only if substrates are completely dry,
free of ice or frost, and clean. Shelf life is 1 year for cartridges and sausages in their
• Low temperatures will extend curing times. original, unopened packaging under normal conditions.
• Substrates such as copper, stainless and galvanized PRECAUTIONS
typically require the use of a primer; Primer 733 or Use only with adequate ventilation. Prevent contact with
766 are acceptable. For Kynar coating use Primer skin, eyes, and clothing. Wash thoroughly after handling.
733 only. An adhesion test is recommended for any Use impervious gloves, eye protection and if the TLV is
other questionable substrate. exceeded or used in a poorly ventilated area, use
• Proper application is the responsibility of the user. approved respiratory protection.
Field visits by BASF Construction Chemicals
Technical Representatives are for the purpose of For the full health and safety hazard information and how
making technical recommendations only and not for to safely handle and use this product, please make sure
supervising or providing quality control on the jobsite. that you obtain a copy of the BASF Construction
Chemicals Material Safety Data Sheet (MSDS)
(MSDS from our
office or our website.

S SonUltra/
SonUltra/10/0
10/0509
/0509
The technical information and application advice given in this BASF Construction Chemicals publication are based on
STATEMENT OF the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
RESPONSIBILITY assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is
responsible for checking the suitability of products for their intended use. BASF Construction Chemicals data sheets
are updated on a regular basis and it is the user’s responsibility to obtain the most recent issue.
Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either orally or
NOTE in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not BASF
Construction Chemicals,
Chemicals are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals offices in ASEAN


Singapore Malaysia Indonesia Thailand Vietnam Philippines
Tel: +65-6861-6766 Tel: +60-3-5628-3888 Tel: +62-21-526-2481 Tel: +66-2-664-9222 Tel: +84-650-374-3100 Tel: +63-2-889-4321
Fax: +65-6861-3186 Fax: +60-3-5628-3776 Fax: +62-21-526-2541 Fax: +66-2-664-9267 Fax: +84-650-374-3200 Fax: +63-2-889-4361
Website: www.ap.cc.basf.com

You might also like