h1(mm)

h2(mm)

h3(mm)

h4
h5
h6a
h6b
h7
h8
valeur de comparaison change units to

90% case title

choix du type de sparateur

uinlet volumic fraction 100% operating conditions


description separateur vertical 2 phasique

gas phase

liquid phase

Calculation parametre

General requirements

Gas Section requirements

Liquid section requirements


Criteria for nozzle sizing
dimentionnement d'un 2phasique v

elipsoidale head (mm)


h1=100 si(ID)<ou=1200
h2=600 si1200< (ID) <1200
h1=0,15*ID si (ID)>4000
hemisphérique heads
h1=150
whitout demister with wire mesh
h2=100 for no hc deposit
h2=0
h2=150 for hc deposit
h1+h2=0,15*5(ID) with h3=300+ d/2 si (ID)<900
h3=max(0,5*(ID),450+d/2
si (id)>900
h4=max(1,5x d,400 + d/2)

hold up time must be 1 to 2minutes, with hs > 150 if LSHH is required and h5 = 0 otherwise

v1(h6a) = max(vslug , vsurge / 2),with h6a >150

v1(h6a) = max( vsurge / 2 ,vret- v1(h7) - vhead),with h6a >150

hold up time must be 1 to 2minutes, with h7 > 200 if LSLL is required and h7 = 0 otherwise
hold up time between the LSLL and the outlet must be enough to shutdown the pump or close or the SDV (about 1s per inch of outlet diame

1st step inpout data

vertical two phase gas-liquid separator design


ange units to metric(TP/RM)

se title

fluid conditions and prosperties

erating conditions
operating temperature °c 65.0
amblet pressure bar abs 1.000
operating pressure bar g 0.000
pressure safety valve discharging to flare network
Design pressure 2.000
bar g

s phase
gas phase name air with pentane
gas mass flowrate kg/h 19210
gas density at operating conditions kg/m3 1.22
gass volumic flowrate at operating conditions m3/h 15745.902

uid phase
liquid phase name water
liquid mass flowrate kg/h 230.0
liquid density at operating conditions kg/m3 1000.00
liquid volumic flowrate at operating conditions m3/h 0.230

2st step inpout

Design requirements
lculation parametre
Click on the button modify calculation parameters parameters

neral requirements
Head type Ellipsiodal
Valeur Minimale ratio(L/D) 2
Valeur Maximale ratio(L/D) 4

s Section requirements
Demister wire mesh pad
hydrocarbon deposit
souders & brown kfactor m/s 0.08
gas flowrate margin % 0
minimal vessel internal diameter mm 16.3928716507586

quid section requirements


gas/liquid retention time
depends on relative density, 1 to 4minutes min
surge capacity
depends on service, 3 to 15 minutes min

slug capacity
from flow assurance data (specific E&P) m3

hold up time between LAH and LSHH


Between 1 and 2 minutes min

hold up time between LAL and LSLL


Between 1 and 2 minutes min

teria for nozzle sizing


Inlet nozzle rv2 requirement Pa 1000
gas oulet nozzle requirment Pa 3750
liquid outlet nozzle maximum velocity m/s 1.5
nnement d'un 2phasique ver

(ID)

LSHH
LAH

NLL
LAL
LSLL

s per inch of outlet diame

design
65.0
1.000
0.000
flare network QmT(kg/h) 19440.00
2.000
QvT(m3/h) 15746.13 qvt(m3/s) 4.37392546

mv(kg/m3) 1.23
ir with pentane
19210 V(m/s) 28.460256419
1.22
15745.902 d 0.0467818081 vg
2.28899577

water
230.0
1000.00
0.230

parameters

Ellipsiodal
2
4

wire mesh pad

0.08
0 vg
16.3928716507586 2.072
qtv

4347.82616

qt

1.450

0.0003335

1000
3750
1.5
h1(mm) elipsoidale head (mm)
h1=100 si(ID)<ou=1200
h2=600 si1200< (ID) <1200
h1=0,15*ID si (ID)>4000
hemisphérique heads
h1=150
whitout demister with wire mesh
h2=100 for no hc deposit
h2=0
h2(mm) h2=150 for hc deposit
h3(mm) h1+h2=0,15*5(ID) with h3=300+ d/2 si (ID)<900
900<h1+h3<1800 h3=max(0,5*(ID),450+d/2
si (id)>900