Professional Documents
Culture Documents
Sl343-Sl343 2021 Advancemdb Survey Cme TSSR Globe-Expansion2020 (Aborox)
Sl343-Sl343 2021 Advancemdb Survey Cme TSSR Globe-Expansion2020 (Aborox)
6-2018
GLOBE TELECOM
ADVANCE ENGINEERING
Page 1 of 81
Genesis-TSSR_Rel.v4.6-2018
✘ ✘ ✘ ✘✘
✘
✘ ✘ ✘
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Page 2 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
A2. Tower
A2.1. Tower Leg/Pole Diameter
A2.1.1. Existing Tower/Pole Information
Tower/Pole type: Guyed Mast Pole Remarks: GREENFIELD
Tower/Leg type: Tubular (O) Remarks: N/A
Tower/Pole Height: 42 m Building Height: N/A m
Total Height: 42 m
A2.1.2. Tower Leg/Pole Diameter of Proposed Antenna Location
Diameter of Pole/Diameter of Tower Leg/size of Tower Leg (Angle Steel): 140 mm.
A2.1.3. Tower Leg/Pole Diameter sampling Per section (use Antenna AMB for height reference)
Height (m) Mast/Leg Size or Dia(mm) Tower Leg Distance (m) Remarks
TOP 170 N/A TUBULAR
MIDDLE 155 N/A TUBULAR
BOTTOM 140 N/A TUBULAR
Page 3 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
A3.1. Site location &Obstructions
Screen shot of actuall site survey location Antenna Blockage XXX ( DEG)
Page 4 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
A3.2 Pictures of Site and Tower Site Defect Report (that affects project implementation/acceptance)
N/A
N/A N/A
Nearest Access Road Obstacle upon Entering the Site Obstacle upon Entering the Site
N/A
Page 5 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Configurations
Electrical Tilt 2 2
AMB TYPE TUBULAR
Page 6 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 2
Antenna Name GU900 ANTENNA
Antenna Brand FADED LABEL
Antenna Model FADED LABEL
Serial No. FADED LABEL
Asset No. N/A
Cell Coverage Outdoor
Solution Type Macro
Cell Coverage Objective RESIDENTIAL AREA
Ant. Lattitude 10.347672
Ant. Longitude 119.261471
Azimuth 160
Tower Height 39
Building Height N/A
with RET NO
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) 39
Mechanical Tilt N/A
No. of Ports 2
RRU/ Combiner Model MRFU V1
Antenna Status In Service
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
On-Air On-Air
Configurations
Electrical Tilt 2 2
AMB TYPE TUBULAR
Page 7 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 3
Antenna Name GU900 ANTENNA
Antenna Brand FADED LABEL
Antenna Model FADED LABEL
Serial No. FADED LABEL
Asset No. N/A
Cell Coverage Outdoor
Solution Type Macro
Cell Coverage Objective RESIDENTIAL AREA
Ant. Lattitude 10.347672
Ant. Longitude 119.261471
Azimuth 240
Tower Height 39
Building Height N/A
with RET NO
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) 39
Mechanical Tilt N/A
No. of Ports 2
RRU/ Combiner Model MRFU
Antenna Status In Service
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
On-Air On-Air
Configurations
Electrical Tilt 2 2
AMB TYPE TUBULAR
Page 8 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
GU900 2PORTS ANTENNA
SECTOR 1 SECTOR 2 SECTOR 3
Shot of Coverage Objectives Shot of Coverage Objectives Shot of Coverage Objectives
Picture of AMB
RRU/RFU Location
Overview of Antenna
Page 9 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 1
Antenna Name N/A
Antenna Brand N/A
Antenna Model N/A
Serial No. N/A
Asset No. N/A
Cell Coverage N/A
Solution Type N/A
Cell Coverage Objective N/A
Ant. Lattitude N/A
Ant. Longitude N/A
Azimuth N/A
Tower Height N/A
Building Height N/A
with RET N/A
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) N/A
Mechanical Tilt N/A
No. of Ports N/A
RRU/ Combiner Model N/A
Antenna Status N/A
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
Configurations
Electrical Tilt
AMB TYPE
Page 10 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 2
Antenna Name N/A
Antenna Brand N/A
Antenna Model N/A
Serial No. N/A
Asset No. N/A
Cell Coverage N/A
Solution Type N/A
Cell Coverage Objective N/A
Ant. Lattitude N/A
Ant. Longitude N/A
Azimuth N/A
Tower Height N/A
Building Height N/A
with RET N/A
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) N/A
Mechanical Tilt N/A
No. of Ports N/A
RRU/ Combiner Model N/A
Antenna Status N/A
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
Configurations
Electrical Tilt
AMB TYPE
Page 11 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 3
Antenna Name N/A
Antenna Brand N/A
Antenna Model N/A
Serial No. N/A
Asset No. N/A
Cell Coverage N/A
Solution Type N/A
Cell Coverage Objective N/A
Ant. Lattitude N/A
Ant. Longitude N/A
Azimuth N/A
Tower Height N/A
Building Height N/A
with RET N/A
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) N/A
Mechanical Tilt N/A
No. of Ports N/A
RRU/ Combiner Model N/A
Antenna Status N/A
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
Configurations
Electrical Tilt
AMB TYPE
Page 12 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
WCC_1 (Type Antenna2)
WCC_1A WCC_2A WCC_3A
Shot of Coverage Objectives Shot of Coverage Objectives Shot of Coverage Objectives
Page 13 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Existing Baseband Unit
BBU Name 2G/3G
BBU Model BBU3900
Asset No. N/A
Serial No. UNREADABLE
BBU Sharing Capable YES
BBU Status INSERVICE
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
On-Air On-Air
0º 30º 60º
Page 14 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Configurations
Electrical Tilt
Page 15 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 2
Antenna Name GUL900/G1800/L2100 ANTENNA
Antenna Brand HUAWEI
Antenna Model ASI4517R3v06
Cell Coverage Outdoor
Solution Type Macro
Cell Coverage Objective RESIDENTIAL AREA
Ant. Lattitude 10.347672
Ant. Longitude 119.261471
Azimuth 160
Tower Height 39
Building Height N/A
with RET YES
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) 39
Mechanical Tilt N/A
No. of Ports 12
RRU/ Combiner Model RRU5512/RRU5502
Antenna Solution Antenna Change-out
G9 G18 U9 U21 L9 L18 L21 L26 MIMO26 NR35
Technology Propose Propose
On-Air Proposed On-Air
d d
Configurations
Electrical Tilt
Page 16 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 3
Antenna Name GUL900/G1800/L2100 ANTENNA
Antenna Brand HUAWEI
Antenna Model ASI4517R3v06
Cell Coverage Outdoor
Solution Type Macro
Cell Coverage Objective RESIDENTIAL AREA
Ant. Lattitude 10.347672
Ant. Longitude 119.261471
Azimuth 240
Tower Height 39
Building Height N/A
with RET YES
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) 39
Mechanical Tilt N/A
No. of Ports 12
RRU/ Combiner Model RRU5512/RRU5502
Antenna Solution Antenna Change-out
G9 G18 U9 U21 L9 L18 L21 L26 MIMO26 NR35
Technology Propose Propose
On-Air Proposed On-Air
d d
Configurations
Electrical Tilt
Page 17 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector1 Sector2 Sector3
Shot of Coverage Objectives Shot of Coverage Objectives Shot of Coverage Objectives
Overview of Antenna
✘
1. CHANGE-OUT EXISTING GU900 2PORTS ANTENNA TO 12PORTS HUAWEI (ASI4517R3v06) FOR
GUL900/G1800/L2100 ANTENNA @43m REUSE AMB.
2. PROPOSE RRU5502 G1800+L2100 AT THE BACK OF ANTENNA.
3. PROPOSE RRU5512 FOR GUL900 PROPOSE NEW RRU-MB.
4. SHUTDOWN GU900 MRFU AT THE BTS CABINET.
✘
✘ NEW AMB (specify) ✘ NEW AMB (specify) ✘ NEW AMB (specify)
✘ ✘ ✘
Page 18 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C8. Cable Interface
Power Cable: LENGTH
Cable Routing:
Single Length of -48V from EPU/DCDU to RECTIFIER 10x3 m
Single Length of -48V from RRU/RFU to DCDU Sector 1 50 m
Sector 2 50 m GUL9
Sector 3 50 m
Page 19 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
B.2 Proposed RF Antenna
Sector Number Sector 1
Antenna Name N/A
Antenna Brand N/A
Antenna Model N/A
Cell Coverage N/A
Solution Type N/A
Cell Coverage Objective N/A
Ant. Lattitude N/A
Ant. Longitude N/A
Azimuth N/A
Tower Height N/A
Building Height N/A
with RET N/A
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) N/A
Mechanical Tilt N/A
No. of Ports N/A
RRU/ Combiner Model N/A
Antenna Solution N/A
Antenna Status N/A
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
Configurations
Electrical Tilt
Page 20 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 2
Antenna Name N/A
Antenna Brand N/A
Antenna Model N/A
Cell Coverage N/A
Solution Type N/A
Cell Coverage Objective N/A
Ant. Lattitude N/A
Ant. Longitude N/A
Azimuth N/A
Tower Height N/A
Building Height N/A
with RET N/A
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) N/A
Mechanical Tilt N/A
No. of Ports N/A
RRU/ Combiner Model N/A
Antenna Solution N/A
Antenna Status N/A
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
Configurations
Electrical Tilt
Page 21 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector Number Sector 3
Antenna Name N/A
Antenna Brand N/A
Antenna Model N/A
Cell Coverage N/A
Solution Type N/A
Cell Coverage Objective N/A
Ant. Lattitude N/A
Ant. Longitude N/A
Azimuth N/A
Tower Height N/A
Building Height N/A
with RET N/A
Feeder Type N/A
Feeder Length (m) N/A
Elevation (m) N/A
Mechanical Tilt N/A
No. of Ports N/A
RRU/ Combiner Model N/A
Antenna Solution N/A
Antenna Status N/A
G9 G18 U9 U21 L7 L18 L23 L26 MIMO26 NR35
Technology
Configurations
Electrical Tilt
Page 22 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
Sector1 Sector2 Sector3
Shot of Coverage Objectives Shot of Coverage Objectives Shot of Coverage Objectives
✘ ✘ ✘✘
Page 23 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C8. Cable Interface
Power Cable: LENGTH
Cable Routing:
Single Length of -48V from EPU to RECTIFIER m
Single Length of -48V from RRU/RFU to DCDU Sector 1 m
Sector 2 m
Sector 3 m
Page 24 of 81
Site Name
ABOROX
PLA ID
SL343
RF INFORMATION SUMMARY
Antenna Summary
*** Existing Antenna Quantity 3 PCS Proposed Antenna Quantity 0 PCS
RF Antenna Summary
Count Antenna Name Serial No. Asset No. Antenna Status Azimuth Sector Tower Height Building Height Elevation (ACL) Antenna Brand Antenna Model No. of Ports Configuration Antenna StatusRRU/Combiner Model Cell Coverage
Cell Coverage Objective
Solution Type
Feeder Type
Feeder Length (m)AMB Type with RET? M. Tilt E. Tilt Latitude Longitude G9 G18 U9 U21 L7 L18 L23 L26 MM26 NR35
FADED RESIDENTI
1 GU900 ANTENNA LABEL N/A On-Air 0 1 39 N/A 39 FADED LABEL FADED LABEL 2 # of Carriers In Service MRFU V1 Outdoor AL AREA Macro N/A N/A Tubular No N/A 2 10.347672 119.26147 On-Air On-Air
FADED RESIDENTI
2 GU900 ANTENNA LABEL N/A On-Air 160 2 39 N/A 39 FADED LABEL FADED LABEL 2 # of Carriers In Service MRFU V1 Outdoor AL AREA Macro N/A N/A Tubular No N/A 2 10.347672 119.26147 On-Air On-Air
FADED RESIDENTI
3 GU900 ANTENNA LABEL N/A On-Air 240 3 39 N/A 39 FADED LABEL FADED LABEL 2 # of Carriers In Service MRFU V1 Outdoor AL AREA Macro N/A N/A Tubular No N/A 2 10.347672 119.26147 On-Air On-Air
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
PLA ID SL343
Count Serial/Asset No Size (m) Antenna HT. (m) Azimuth Status Equipment Remarks
1 FADED LABEL 3.5 BELOW THE TOWER N/A In Service ANATEL IN A GOOD CONDITION
For
2 FADED LABEL 3.5 BELOW THE TOWER N/A Decommissioning MICROWAVE FOR DISMANTLE
For
3 1066866 3.5 BELOW THE TOWER N/A Decommissioning MICROWAVE FOR DISMANTLE
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
REGROOMING 20180214
Pictures of MW:
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
B1. RF Antenna Information
B1.1. General Information
Enough space to install MW antenna of this project? Facing :
Proposal for MW
Main MW Diversity MW (SD)
Antenna
Latitude (DLL) of Antenna
Longitude (DLL) of Antenna
Antenna Height (m)
Antenna Orientation
Down tilt (Mechanical)
Down tilt (Electrical)
Type/Model of Antenna
MW Antenna solution
N/A
Page 29 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 30 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
1. OUTDOOR (Panoramic Picture from edge to edge)
From the rear edge of Site looking at Site Entrance (Facing the GF Gate/RT roof Access)
From the left edge of Site looking at Right Side (Facing the rear of GF Gate/Rooftop Door Access)
From the front edge of Site looking at Rear of Site (Facing the rear of GF Gate/Rooftop Door Access)
From the right edge of Site looking at Left Side (Facing the rear of GF Gate/Rooftop Door Access)
Page 31 of 81
Genesis-TSSR_Rel.v4.6-2018
2. TOWER TOP TO GROUND VIEW (While on top of tower take picture looking downwards)
From the top of tower looking down at Site Entrance (Facing the GF Gate/RT roof Access)
From the top of tower looking down at Right Side (Facing the rear of GF Gate/Rooftop Door Access)
From the top of tower looking at Rear of Site (Facing the rear of GF Gate/Rooftop Door Access)
From the top of tower looking at Left Side (Facing the rear of GF Gate/Rooftop Door Access)
Page 32 of 81
Genesis-TSSR_Rel.v4.6-2018
N/A N/A
Page 33 of 81
Genesis-TSSR_Rel.v4.6-2018
N/A N/A
2G/3G
Existing Overall BBU1 Existing Overall BBU2 Existing Overall BBU3
5. Transport Information
5.1. Existing Equipment Type:
TRS eqp Huawei CX600-X8 Huawei CX600-X2 Huawei ATN950B Huawei ATN950 MICROWAVE
W/on site
QTY
Others, Please state total quantity and fill in the detail as below table. Quantity: 1
5.1.1 - transport ports detail inform for BBUs(TRS ports for BBUs)
TRS Eqp to BBU BTS TRS Eqp to BBU TRS Eqp to BBU3 TRS Eqp to BBU
Page 34 of 81
Genesis-TSSR_Rel.v4.6-2018
N/A
Page 35 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 36 of 81
Genesis-TSSR_Rel.v4.6-2018
BBU BBU
COLOCATE 2G/3G BBU AT PROPOSE NEW LTE BBU AT COLOCATE L9 TO NEW LTE
EXISTING APM30H. EXISTING TMC. BBU AT EXISTING TMC.
BBU Sol'n : Collocate BBU Sol'n : New installation BBU Sol'n : Collocate
Cabinet Sol'n : collocate Cabinet Sol'n : collocate Cabinet Sol'n : collocate
G18 L21 L9
DCDU
DCDU
Page 37 of 81
N/A N/A N/A
Genesis-TSSR_Rel.v4.6-2018
Propose new TRS equipment location Propose TRS equipment (reuse cabinet) Reuse Available GE/FE Ports
Page 38 of 81
Genesis-TSSR_Rel.v4.6-2018
Exixting ID/OD Cable Ladder 1 Exixting ID/OD Cable Ladder 2 Exixting Vertical Cable Ladder 3
N/A N/A
Layers of Feeder Cable on Existing Layers of Feeder Cable on Existing Layers of Feeder Cable on Existing
ID/OD Cable Ladder 1 ID/OD Cable Ladder 2 Vertical Cable Ladder 3
N/A N/A
Proposed ID/OD Cable Ladder 1 Proposed ID/OD Cable Ladder 2 Proposed Vertical Cable Ladder 3
Existing GPS Location Proposed GPS Location Proposed Surge protector location
GPS cable length : GPS DIVIDER FOR --- : ✘ Yes No
Page 39 of 81
Genesis-TSSR_Rel.v4.6-2018
8.3 Busbar
8.3.1. Grounding Busbar (Proposed for BBU, DCDU, GPS, New Cabinet / Rack) (Indoor)
Reuse Existing Bus Bar Remark:
New Busbar Required: New Hole's Qty Required: Holes' diameter: mm
Remark:
Proposed 38mm² bare/insulated copper wire: m Grounding Test Result :
8.3.2 Picture of Proposed Busbar (Proposed for BBU, DCDU, GPS, New Cabinet / Rack) (Indoor)
N/A
Available holes for use Proposed Outdoor Busbar Proposed Outdoor Busbar
8.3.4b Picture of Proposed Busbar near tower/antenna(Tower)
N/A
Available holes for use
8.4 Feeder Window Information
Reuse Existing Feeder Window Available Holes:
New Feeder Window is required Qty Required:
Remark: OUTDOOR SITE
8.4.1 Picture of Existing and Proposed Feeder Window
Existing Feeder Window New Feeder Window (Inside Cabin) New Feeder Window (Outside Cabin)
Page 40 of 81
Genesis-TSSR_Rel.v4.6-2018
9. DC Power
9.1. Rectifier System Load Breakers/ Fuse Total No. of Rectifier System
Cabin/Outdoor 1 RECTIFIER SYSTEM 1 RECTIFIER SYSTEM 2
Existing Rectifier Specify brand/name : APM30H
Rectifier Asset #
Rectifier System Capacity 56.17978 Vdc #NAME? Vdc
Rectifier Module Capacity (Watts): 1500 W 28.08989 A #N/A W #NAME? A
Installed rectifier modules: 2
Operational rectifier modules: 2
Defective rectfier modules: 0
The number of empty modules space: 1
Actual Current of DC Load Panel display / clamp meter 20.59 A A
Actual Float Voltage : 27.1 V V
(234*4.7)/53.4=20.59
EXISTING RECTIFIER 1 RECTIFEIR 1 MODULES RS1 ACTUAL LOAD READING
Page 41 of 81
Genesis-TSSR_Rel.v4.6-2018
PSU
F1 NADER 16 1 NO LABEL ON
F2 NADER 16 1 NO LABEL ON
F3 NADER 16 1 SPARE OFF
AC OUTPUT
F4 NADER MIGRANT EXISTING
16 2 SPARE OFF LOADING TO NEW RS.
F5 NADER
DC
F6 NADER 100 1 BAT ON
F7 NADER 80 1 RFC1 ON
F8 NADER 80 1 RFC2 ON
F9 NADER 25 1 TMC ON
Note: Put in "Remark" above for new or existing breaker to be used for proposed equipment
9.2.2. Rectifier System 2 (EXISTING RECTIFIER 2)
9.2.2.2 Rectifier System3 (EXISTING RECTIFIER 3)
9.2.2.4 Rectifier System 4 (EXISTING RECTIFIER 4)
Page 42 of 81
Genesis-TSSR_Rel.v4.6-2018
BATTERY
B1 NADER 125 1 BATTERY 1 OFF
B2 NADER 125 1 BATTERY 2 OFF
B3 NADER 125 1 BATTERY 3 OFF
B4 NADER 125 1 BATTERY 4 OFF
LOAD LOW VOLTAGE DISCONNECT (LLVD)
PROPOSE TAPPING PT
F1 NADER 100 1 SPARE OFF FOR G18+L21. UTILIZE
100AT.
F2 NADER 100 1 SPARE OFF
F3 NADER 80 1 SPARE OFF
F4 NADER 80 1 SPARE OFF
F5 NADER 80 1 SPARE OFF
F6 NADER 80 1 SPARE OFF
PROPOSE TAPPING PT
F7 NADER 63 1 SPARE OFF
FOR L900. UTILIZE 63AT.
F8 NADER 63 1 SPARE OFF
F9 NADER 32 1 SPARE OFF
F10 NADER 32 1 SPARE OFF
F11 NADER 32 1 SPARE OFF
F12 NADER 32 1 SPARE OFF
F13 NADER 16 1 SPARE OFF
F14 NADER 16 1 SPARE OFF
F15 NADER 16 1 SPARE OFF
F16 NADER 16 1 SPARE OFF
F17 NADER 10 1 SPARE OFF
F18 NADER 10 1 SPARE OFF
F19 NADER 10 1 SPARE OFF
F20 NADER 10 1 SPARE OFF
F21 NADER 10 1 SPARE OFF
F22 NADER 10 1 SPARE OFF
BATTERY LOW VOLTAGE DISCONNECT (BLVD)
F23 NADER 63 1 SPARE OFF
F24 NADER 63 1 SPARE OFF
F25 NADER 63 1 SPARE OFF
F26 NADER 63 1 SPARE OFF
F27 NADER 16 1 SPARE OFF
F28 NADER 16 1 SPARE OFF
F29 NADER 16 1 SPARE OFF
F30 NADER 16 1 SPARE OFF
Note: Put in "Remark" above for new or existing breaker to be used for proposed equipment
8.2.5. Proposed Rectifier System Load Breakers/Fuse (HT-MINI RECTIFIER) ID TYPE RS: 442mm x 360mm x 480mm
8.2.5. Proposed Rectifier System Load Breakers/Fuse (HT-MTS9513A) OD TYPE RS: 815mm x 815mm x 2340mm
8.2.5. Proposed Rectifier System Load Breakers/Fuse (HT-TP48200A) OD TYPE RS: 600mm x 600mm x 2200mm
8.2.5. Proposed Rectifier System Load Breakers/Fuse (HT-TP4860C)OD TYPE RS: 450mm x 300mm x 630mm
Page 43 of 81
Genesis-TSSR_Rel.v4.6-2018
N/A N/A
Page 44 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
AC. Power Source (Supply)
1. Primary Power Source Commercial Power + DG
Only commercial Power ✘ Commercial Power+DG Only DG
Solar+DG DCB+DG Temporary Tapping to Neighbor/Lessor
Commercial Power Provider : MERALCO Permanent or Temporary P
Electrical Connectivity: Permanent_Solely Used If Submetered; Provisioned Load:
Picture of Transformer/ Submetered Load zoom in picture for Capacity Drop Wire pictures
ATS: Brand:POWERCITY Capacity: 125 AT Cable Size: 40 mm2 Cable Length: 8 m STATUS: In-Good-Condition
MTS: Brand: Capacity: AT Cable Size: mm 2 Cable Length: m STATUS:
KWHR SN: 3403616 ATS: 236 MTS V: MTS L1: MTS L2: MTS L3:
MDP Information
The Main CB: Amps STATUS:
Page 45 of 81
N/A N/A N/A
Genesis-TSSR_Rel.v4.6-2018
L1 = A L2 = A L3 = A
Page 46 of 81
Genesis-TSSR_Rel.v4.6-2018
N/A
ACPDB(No.1) Details
Asset #: 235079
AC Cable size(mm²) 40
PDB/P Main Breaker Amps. 60 No. of Branches 6
P-BTS Cable Length(m) 10
Load Amp
no. Brand Rating No. of Pole Load Description Status Remark
L1(A) L2(A)
1 SQUARE D 50 2 SPARE OFF
2 SQUARE D 32 2 SPARE OFF
3 SQUARE D 20 2 SPARE OFF
4 SQUARE D 20 2 NO LABEL ON
5 SQUARE D 20 2 C.O ON
6 SQUARE D 20 2 SPARE OFF
7
8
9
10
11
12
13
14
15
16
Note: Put in "Remark" above for special case if there is
TVSS Detail: Brand: Rating: KAIC
Asset #:
N/A
N/A
Page 47 of 81
Genesis-TSSR_Rel.v4.6-2018
L1 = 4.7 A L2 = 4.6 A L3 = A
Page 48 of 81
Genesis-TSSR_Rel.v4.6-2018
ACPDB(No.2) Details
Asset #:
Cable size(mm²)
AC
PDB/P Main Breaker Amps. No. of Branches
P-BTS Cable Length(m)
Load Amp
no. Brand Rating No. of Pole Load Description Status Remark
L1(A) L2(A)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Note: Put in "Remark" above for special case if there is
TVSS Detail: Brand: Rating: KAIC
Asset #:
L1 = A L2 = A L3 = A
Page 49 of 81
Genesis-TSSR_Rel.v4.6-2018
N/A
N/A N/A
N/A
N/A N/A
Existing DG Existing Fuel Tank Pictures with basepad for DG and fuel tank
Page 50 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 51 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 52 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C7. Rectifer1 Computation
C7.1. EXISTING RECTIFIER
1) EXISTING RECTIFIER SYSTEM BRAND - MODEL APM30H
2) MAXIMUM RECTIFIER MODULES / INSTALLED 3 2
3) RECTIFIER MODULE RATING, WATTS / AMPS 1500 28.08989
4) BATTERY BRAND / VOLTAGE RATING WOLONG 48
5) NUMBER OF BATTERIES in BANKS / CAPACITY per CELL (AH) 1 100
6) PRESENT LOAD READING, PANEL DISPLAY / CLAMP METER (A) 20.59 Ampere
7) RECTIFIER MODULES IN OPERATION 2 modules
8) ACTUAL FLOAT VOLTAGE (V) 27.1 Voltage
C7.2. PROPOSED PDU/DCDU RECTIFIER LOAD SCHEDULE
PROPOSED ADDITIONAL LOAD(S)
Equipment Type Power Rating Current Rating Cable Size Circuit Breaker Deployment
Load No
(Load Description) (Watts) (Amps) (AWG) Rating (Amps) Remarks
1 N/A 0 0 #N/A
2 N/A 0 0 #N/A
3 N/A 0 0 #N/A
4 N/A 0 0 #N/A
5 N/A 0 0 #N/A
6 N/A 0 0 #N/A
7 N/A 0 0 #N/A
TOTAL: 0
Total Full Load Current = Existing Load + Proposed Load (100% of Rated Load) = 20.59 Amps
Existing Rectifier Capacity: No. Modules x Ampere Capacity = 56.17978 Amps
Existing Battery Capacity: No. of Batt Banks x Batt Capacity = 100 AH
Available Rectifier Capacity = Existing Rectifier Capacity - (Total Full Load Current) - (10% of Battery Capacity)
- Rectifier Module Current Rating
Available Rectifier Capacity = 56.17978 Amps - 20.59 Amps - ( 100 * 0.05) - 28.08989 Amps
Available Rectifier Capacity = 2.49989 Amperes (if result value is negative, provision of additional module is required)
Percent Utilization (TLC/Existing Rectifier Capacity) = 37%
BATTERY BACK-UP TIME COMPUTATION:
C7.3. END-STATE SUFFICIENCY COMPUTATION: (applicable only if there will be new Rectifier System or Upgraded Module)
Available Rectifier Capacity = (Future Rectifier Capacity - (Total Full Load Current) - (10% of Battery Capacity)
- Rectifier Module Current Rating
Available Rectifier Capacity =
Available Rectifier Capacity = Amperes (if result value is negative, provision of additional module is required)
Percent Utilization (TLC/Existing Rectifier Capacity) =
C7.4. EQUIPMENT FOR DECOMMISION: (Applicable for sites with identified equipment for decomisioning)
1.) Please in put if any : Amperes (value from clampmeter reading)
2.) please in put if any : Amperes (value from clampmeter reading)
TOTAL FOR DECOM : Amperes
Page 53 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C8. Proposed Rectifer Computation
C8.1. PROPOSED RECTIFIER
1) Propose RECTIFIER SYSTEM BRAND - MODEL MTS9304A
2) MAXIMUM RECTIFIER MODULES / INSTALLED 6 4
3) RECTIFIER MODULE RATING, WATTS / AMPS 3000 56.18
4) BATTERY BRAND / VOLTAGE RATING NARADA 12
5) NUMBER OF BATTERIES in BANKS / CAPACITY per CELL (AH) 4 150
6) PRESENT LOAD READING, PANEL DISPLAY / CLAMP METER (A) 20.59 Ampere
7) RECTIFIER MODULES IN OPERATION 4 modules
8) ACTUAL FLOAT VOLTAGE (V) 53.4 Voltage
C8.2. PROPOSED PDU/DCDU RECTIFIER LOAD SCHEDULE
PROPOSED ADDITIONAL LOAD(S)
Equipment Type Power Rating Current Rating Cable Size Circuit Breaker
Load No Remarks
(Load Description) (Watts) (Amps) (AWG) Rating (Amps)
5 N/A 0 0 #N/A
6 N/A 0 0 #N/A
7 N/A 0 0 #N/A
Totally 65.65543071
Total Full Load Current = Existing Load + Proposed Load (100% of Rated Load) = 86.245431 Amps
Existing Rectifier Capacity: No. Modules x Ampere Capacity = 224.72 Amps
Existing Battery Capacity: No. of Batt Banks x Batt Capacity = 600 AH
Available Rectifier Capacity = Existing Rectifier Capacity - (Total Full Load Current) - (10% of Battery Capacity)
- Rectifier Module Current Rating
Available Rectifier Capacity = 224.72 Amps - 86.245431 Amps - ( 600 * 0.1) - 56.18 Amps
Available Rectifier Capacity = 22.294569288 Amperes (if result value is negative, provision of additional module is required)
Percent Utilization (TLC/Existing Rectifier Capacity) = 38.38%
BATTERY BACK-UP TIME COMPUTATION:
C8.3. END-STATE SUFFICIENCY COMPUTATION: (applicable only if there will be new Rectifier System or Upgraded Module)
Available Rectifier Capacity = (Future Rectifier Capacity - (Total Full Load Current) - (10% of Battery Capacity)
- Rectifier Module Current Rating
Available Rectifier Capacity =
Available Rectifier Capacity = Amperes (if result value is negative, provision of additional module is required)
Percent Utilization (TLC/Existing Rectifier Capacity) =
C8.4. EQUIPMENT FOR DECOMMISION: (Applicable for sites with identified equipment for decomisioning)
1.) n/a : Amperes (value from clampmeter reading)
2.) n/a : Amperes (value from clampmeter reading)
TOTAL FOR DECOM : Amperes
Page 54 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C9. Antenna Mounting Bracket or Pole
Remarks :
Page 55 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C9. Antenna Mounting Bracket or Pole
Remarks :
Remarks :
Page 56 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C9. Antenna Mounting Bracket or Pole
Remarks : l
Antenna Type6 Sector 1 Sector 2 Sector 3
Length of Pole (mm)
Diameter of Pole (mm)
Size of Bolts (mm)
Size of U-Bolts (mm)
Distance of pole to tower leg /
building wall (mm)
Antenna Type6 Sector 4 Sector 5 Sector 6
Length of Pole (mm)
Diameter of Pole (mm)
Size of Bolts (mm)
Size of U-Bolts (mm)
Distance of pole to tower leg /
building wall (mm)
Pole Bolts U Bolts
Remarks :
Page 57 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
C9. Antenna Mounting Bracket or Pole
Remarks :
Remarks :
Page 58 of 81
Genesis-TSSR_Rel.v4.6-2018
D1. Existing Site development layout Drawing File Name : ADVANCE ENGINEERINGSL343
Page 59 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 60 of 81
Genesis-TSSR_Rel.v4.6-2018
D2. Proposed Site development layout Drawing File Name : ADVANCE ENGINEERINGSL343
Page 61 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 62 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 63 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 64 of 81
Genesis-TSSR_Rel.v4.6-2018
D4. Proposed Room Layout (with cable routing layout) Drawing File Name : ADVANCE ENGINEERINGSL343
Page 65 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 66 of 81
Genesis-TSSR_Rel.v4.6-2018
D5. Proposed Layout Outdoor cable routing (from cabin to antenna) Drawing File Name : ADVANCE ENGINEERINGSL343
Page 67 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 68 of 81
Genesis-TSSR_Rel.v4.6-2018
D6. Existing Tower Elevation and Tower Loading Drawing File Name : ADVANCE ENGINEERINGSL343
Page 69 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 70 of 81
Genesis-TSSR_Rel.v4.6-2018
D7. Proposed Antenna Layout(with Proper Northing) Drawing File Name : ADVANCE ENGINEERINGSL343
Page 71 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 72 of 81
Genesis-TSSR_Rel.v4.6-2018
D8. Top View of the Antenna Drawing File Name : ADVANCE ENGINEERINGSL343
Page 73 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 74 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 75 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 76 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 77 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 78 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 79 of 81
Genesis-TSSR_Rel.v4.6-2018
Page 80 of 81
Genesis-TSSR_Rel.v4.6-2018
ADVANCE ENGINEERING
Technical Site Survey Report
Site Name ABOROX
PLA ID SL343
E. Revision History
Page 81 of 81