Parameter Priority For Analysis: Method 1: Data Is Available On Priority 1 Parameters BOD5 and TSS
Parameter Priority For Analysis: Method 1: Data Is Available On Priority 1 Parameters BOD5 and TSS
COD/TKN > 20, then there may be insufficient N for cell growth
COD/TP > 150, there may be insufficient P for cell growth
COD / TN > 5, there may be insufficient carbon for denit
Can be lower in some wastewaters with grit, typical range is 0.7 to 0.9
Range is 1.75 to 2.5 BOD5, higher for raw influent compared to primary effluent
Alternatively, you may use SCOD = 0.5 COD
Sample is flocculated with alum, then filtered and analyzed for COD
Can vary from 10% to 150% of SBOD5, depending on fermentation in the sewers
Range of 5 to 20%, higher with mix of industrial wastewaters
Can be higher if there is cellulosic material, certain industrial feeds
Can be 0.12 COD in plants with recycle from anaerobic digesters, lower in plants with no recycles
Range of 2.5 to 5%, can be high in some industrial wastewaters & plants with anaerobic digesters
Range of 2.5 to 5%, can be high in some indutrial wasatewaters
If plant has recycles from solids handling, it will be 0.5 to 1 mg/L
If plant has recycles from solids handling, it will be 0.5 to 1 mg/L
Range is 0.5
It can also betotaken
1 PCODnbio
as 0.5 (TSS - VSS)
COD/TKN > 20, then there may be insufficient N for cell growth
COD/TP > 150, there may be insufficient P for cell growth
COD / TN > 5, there may be insufficient carbon for denit
Can be lower in some wastewaters with grit, typical range is 0.7 to 0.9
Range is 1.75 to 2.5 BOD5, higher for raw influent compared to primary effluent
Alternatively, you may use SCOD = 0.5 COD
Sample is flocculated with alum, then filtered and analyzed for COD
Can vary from 10% to 150% of SBOD5, depending on fermentation in the sewers
Range of 5 to 20%, higher with mix of industrial wastewaters
Can be higher if there is cellulosic material, certain industrial feeds
Can be 0.12 COD in plants with recycle from anaerobic digesters, lower in plants with no recycles
Range of 2.5 to 5%, can be high in some industrial wastewaters & plants with anaerobic digesters
Range of 2.5 to 5%, can be high in some indutrial wasatewaters
If plant has recycles from solids handling, it will be 0.5 to 1 mg/L
If plant has recycles from solids handling, it will be 0.5 to 1 mg/L
Range is 0.5
It can also betotaken
1 PCODnbio
as 0.5 (TSS - VSS)