Download as pdf or txt
Download as pdf or txt
You are on page 1of 79

Unitrans ZXMP S385 System Structure

ZTE Corporation
Transmission Course Team

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Contents

• System Overview

• Basic Components

• Equipment Structure

• Card Introduction

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
System Overview

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Features

• Optical interface: STM-64/16/4/1 and 155M/622M POS

• Electrical interface: STM-1, E3, E1, T3, etc

• VC4-4C and VC4-16C concatenation

• Perfect equipment level and network level protection

• Reliable timing process capability

• Remote downloading of program and FPGA for OL16, CSA


(without TCS), LP1, E3/T3, E1, OW, NCP cards

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Integrated Design

Can be flexibly configured as a Terminal Multiplexer (TM),


Add/Drop Multiplexer (ADM), and Regenerator (REG).

 Important Remark

When configured as a regenerator, the CS card is needed to be installed.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Multi-service Access Ability

• Integrated with SDH, Ethernet, ATM and RPR technologies

• TDM services (T1/E1, T3/E3, STM-1, etc.)


• POS (155M/622M)
• 10/100M Ethernet Access ( L2 switch, PPP/LAPS/GFP,
Virtual Concatenation)
• Gigabit Ethernet Access
• Convergence from FE to GE
• Embedded RPR
• ATM Access

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Equipment Level Protection

• Dual service and clock buses


• Cross-connect and synchronous clock card 1+1 hot backup
• Power supply unit 1:1 backup
• NCP 1+1 hot backup
• Independent FAN unit
• Tributary Protection System (E1, E3/T3, STM-1)
• Two groups of 1:4 protection for 155M(e)/FE/E3/T3 and
one group of 1:9 protection for E1
• Protection for STM-1 can only protect the service but not
ECC, over head cross connection, OW and MSP chain

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Network Protection

• 4F/2F Multiplex Section Protection Ring

• Path Protection

• Sub-Network Connection Protection (SNCP)

• Dual Node Interconnection (DNI)

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Timing Synchronization Process

• Clock source: external clock, line clock, tributary clock and


internal clock

• 28 line/tributary clock, 4 2Mbit/s or 2MHz, 1 internal clock

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Remote Download Card Program

Remote
Remote software
software download,
download,
easy
easy for
for maintenance
maintenance and
and upgrade
upgrade

ECC ECC ECC

ZXSM ZXSM ZXSM ZXSM

Both program and FPGA of any card can be upgraded remotely !

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Application

• Long distance backbone network


• Area backbone network
• Metropolitan network (Core layer and Convergence layer)

ZXMP S390
ZXMP S385
ZXMP S380
Core layer

ZXMP S385
ZXMP S380
ZXMP S360
Convergence layer ZXMP S330

ZXMP S360
ZXMP S330
ZXMP S320
ZXMP S310
Access layer
ZXMP S100

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Basic Components

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Cabinet

• 300mm(D)x 600mm(W)x 2600mm(H)

• 300mm(D)x 600mm(W)x 2200mm(H)

• 300mm(D)x 600mm(W)x 2000mm(H)

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Cabinet
Power Distribute Unit
Cabling Area Alarm Panel

Front Door
Subrack

Dust-proof Unit

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Subrack

• Should be installed in a 19’


cabinet

• 300mm depth, wiring and


operation in the front.

• Height : 17U

• Weight: 25kg

• Dimension: 754.85mm (H) *


482.6mm (W) * 270mm (D)

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
ZTE University univ.zte.com.cn
univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Subrack Structure

Upper Cabling Outlet

Decorative Door

MB

Card Area

Lower Cabling Area

Fan Plug-in Box

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Motherboard

• Connects all cards and provides interfaces for connecting


ZXMP S385 with external signals
• Service buses, overhead buses, clock buses and card-in-
position buses
• Consists of an upper and lower layer. Service interface cards
are installed in the upper layer while service function cards are
in the lower layer
• It adopts AU-4 multiplexing structure

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Upper Layer Card Structure

Lever
Card PCB
Interface

Lever

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Lower Layer Card Structure

Lever

Panel

Optical Interface

Optical Interface Indicator

Card PCB
Conductive Fabric

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Fan Box

Fan Box Mounting Bracket

Each fan plug-in box


consists of one FMB and
Fan Box
Fan Box three independent fan boxes.
Fan Box Each fan box is composed of
a fan box, a fan and a FAN
card. The fan keeps running
Fan
at full speed all the time and
Indicator
provides the NCP card with
blocking signals.

Fan Box Button Switch

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Dust-Proof Unit

Rear Lug Dust-proof Plate Dust-proof Label


Frame Panel

Used to maintain cleanliness within the subrack since accumulated


dust affects heat dissipation performance of the equipment.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Ventilation Unit

Rear lug Frame Panel

• If two sub-racks are configured in a single cabinet, a ventilation


unit must be installed at the bottom of each subrack to prevent hot
air from entering thus ensuring proper heat dissipation.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Power Distribution Box

Standby Power Air Switch

Mounting Lug Alarm Indicator


Active Power Air Switch

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
External Interfaces

QXI SCI
-48V Power Supply -48V Power Supply

Alarm indication unit interface


ALARM_SHOW External alarm Boolean variable input
Column-head cabinet alarm interface ALARM_IN &UC
interface ALARM_OUT 2Mb/s Rx1
2Mb/s Tx1
Auxiliary subscriber data interface 2Mb/s Rx2
2Mb/s Tx2
AUX
BITS interface (120 Ω)
EMS Qx interface ( RJ45) Two-line analog telephone interface 1
Two-line analog telephone interface 2
Two-line analog telephone interface 3
Extended shelf interface EXT F1 Interface

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
System Structure

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Hardware Platforms

Service access Service cross- Service access


platform . connect platform . platform
. .
. .
Clock processing
platform

Overhead
processing
.
.
.

.
.
.
platform

Power support NE control


platform platform

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
• 18, 19 for NCP, 1+1 hot
connection and clock) , 1+1
• 1~7, 10~16 for service

• 8, 9 for CS (cross
Subrack Slot Layout

• 19 slots for processing cards

hot backup

• 17 for OW

backup
cards

16
Service slot
72

Electrical interface card / Interface Switching card

13 14 15
Service slot
71

Electrical interface card / Interface Switching card

FAN 3
Service slot
70
Electrical interface card / Interface Switching card
69 Service slot
Electrical interface card / Interface Switching card

12
Service slot
68
Electrical interface card / Interface Switching card

10 11
Service slot

67
C C X C
N N Q S

P P I I
Service slot

66

C C

FAN 2
S S

9
18 19

8
7
Service slot

17
O
Service slot

6
64 65
Electrical interface card / Interface Switching card
Service slot

5
Electrical interface card / Interface Switching card
Service slot

FAN 1
63
Electrical interface card / Interface Switching card Service slot

3
62
Electrical interface card / Interface Switching card
Service slot

2
61
Electrical interface card / Interface Switching card Service slot

1
for
61, 72 also for
of 155M (140M), 34/45M,
electrical interface cards
electrical interface cards
Subrack Slot Layout

• 12 slots for interface cards:

• 66, 67 for QxI and SCI


• 61~65, 68~72
only,

FE

16
Service slot
72

Electrical interface card / Interface Switching card

13 14 15
Service slot
71

Electrical interface card / Interface Switching card

FAN 3
Service slot
70
Electrical interface card / Interface Switching card
69 Service slot
Electrical interface card / Interface Switching card

12
Service slot
68
Electrical interface card / Interface Switching card

10 11
Service slot

67
C C X C
N N Q S

P P I I
Service slot

66

C C

FAN 2
S S

9
18 19

8
7
Service slot

17
O
Service slot

6
64 65
Electrical interface card / Interface Switching card
Service slot

5
Electrical interface card / Interface Switching card
Service slot

FAN 1
63
Electrical interface card / Interface Switching card Service slot

3
62
Electrical interface card / Interface Switching card
Service slot

2
61
Electrical interface card / Interface Switching card Service slot

1
 Important Remark
• Relationship between process card and interface card slots
• 61~65 slots used for 1~5 slots

• 68~72 slots used for 12~16 slots

• 51, 52, 53 are used for FAN

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Card Introduction

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
NE Control Processor (NCP)

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
NE Management Functions

• Completes the initial NE configuration.


• Receive and analyze EMS commands.
• Send commands to the cards for corresponding operations.
• Forward messages reported by the cards to the EMS.
• Control alarm output of the equipment and monitor external
alarm input.
• Implement hard or soft reset to the cards, with the aid of EMS.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Functional Diagram

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
NCP Panel

1
Running Status Indicators

f2Interface

3
Debugging Interface

Active
4 Status Indicator

5Reset Button

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Name Description
NOM (green): During normal operation of the
card, it flashes.
Indicator of card running ALM1 (yellow): During normal operation of the
status card, it is on to indicate common alarms of the
(NOM, ALM1, and ALM2) NE.
ALM2 (red): During normal operation of the card,
it is on to indicate severe alarms of the NE.
f interface LCT Interface
Debugging interface Reserved
MS (green): It is on to indicate that the card is in
Active status indicator (MS)
active status.
Reset button (RST) It is used to reset the NCP card.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Cross-Connect and Clock Card (CS)
and
Synchronous Clock Interface Card (SCI)

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Function of CS and SCI

The CS and SCI cards comprise the service cross-connect unit,


overhead cross-connect unit and clock unit of the system.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Functional Diagram

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
CSA

• Total Switching Capacity: 256×256 VC-4

• Space Division Capacity : 224×224 VC-4


• Time Division Capacity : 32×32 VC-4
• Overhead cross-connect capacity: 4096×4096 64 kbit

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Service Buses Distribution

S
N N Q
O C
C C X
W I
P P I
B

622M Service buses


61 62 63 64 65 17 18 19 66 67 68 69 70 71 72

2.5G for each slot

C C
4 4 4 4 4 4 4 S S 4 4 4 4 4 4 4
A A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
CSE

• Total Switching Capacity: 1152×1152 VC-4

• Space Division Capacity : 896×896 VC-4


• Time Division Capacity : 256×256 VC-4
• Overhead cross-connect capacity: 4096×4096 64 kbit

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Service Buses Distribution

S
N N Q
O C
C C X
W I
P P I
B

2.5G Service buses


61 62 63 64 65 17 18 19 66 67 68 69 70 71 72

10G for each slot

C C
4 4 4 4 4 4 4 S S 4 4 4 4 4 4 4
E E

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Time Division Module

• TCS256 256 * 256 VC-4

• TCS128 128 * 128 VC-4

• TCS64 2 * 32 * 32 VC-4

• TCS32 32 * 32 VC-4

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Clock Unit

• The clock unit consists of the CS and SCI cards.

• The objective of network synchronization is to control the


frequency and phase of each node clock within a preset
tolerance range to implement correct and effective transmission
and switching of digital streams on the network and avoid slip
damage to transmission data due to asynchronous clocks.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Connection Between the Clock Unit and Other Cards

System Clock
Switching Control Standby CSA
Output
Service Card
Card Reference
Clock Input
Active CSA
Card External Reference
Clock Output Clock
Interface
NE Control External Reference Card
Card Clock Input

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Functional Diagram
28-channel 8 kHz
line timing input

Timing reference
selection board
interface unit
4-channel

External
clock
2.048 Mbit/s
or 4-channel
2.048 MHz

To
Monitoring Clock generation board
Control unit
unit and allocation unit

Switching
control unit

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Functions

• Provides four external 2.048 Mbit/s or 2.048 MHz clock input


reference and timing input reference of 28 lines (or tributaries)

• Implement protection switching of clock reference sources

• Support dual-card hot backup working mode

• Provide four external reference clocks for output and four


external reference clocks for input. Can be: 2.048 Mbit/s
interface or 2.048 MHz interface

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Working Modes of the Clock Unit

• Fast capture

• Locked

• Holdover

• Free running

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
SCI Card Functions

• Provide four external reference clocks both for input and


output

• Two versions: SCIB and SCIH

• SCIB: two 75 Ω and two 120 Ω interfaces of 2.048 Mbit/s


clock signals
• SCIH: two 75 Ω and two 120 Ω interfaces of 2.048 MHz
clock signals

• The first 75 Ω output interface and the first 120 Ω output


interface have the same clock source, and the second 75 Ω
output interface and the second 120 Ω output interface
have the same clock source.
ZTE University univ.zte.com.cn
univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
CS Panel

Card Running Status Indicators

TCS Indicator
Clock Active Status Indicator
Clock Running Status Indicators

Reset Button

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
CS Indicators

Name Description
NOM (green): Flashes during normal operation
of the card.
Indicator of card running
ALM1 (yellow): During normal operation of the
status
card, it is on to indicate minor alarms of the card.
(NOM, ALM1, and ALM2)
ALM2 (red): During normal operation of the card,
it is on to indicate severe alarms of the card.
TCS (green): It is on to indicate that the TCS is
TCS indicator
in position.
Indicator of clock active MS (green): It is on to indicate that the card is
status (MS) in active status.
Indicator of clock running CKS1 and CKS2 are green.
status
Reset button RST It is used to reset the CSA card.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Indicator
Working Status
NOM ALM1 ALM2 CKS1 CKS2 MS TCS
Normal running Flash Off Off - - - -
Common alarm of the
Flash On - - - - -
card
Severe alarm of the
Flash - On - - - -
card
Locked (normal
Flash - - On On - -
tracing)
Clock holdover Flash - - On Off - -
Fast capture Flash - - Off On - -
Free run Flash - - Off Off - -
Active CSA card Flash - - - - On -
Standby CSA card Flash - - - - Off -
TCS in-position Flash - - - - - On
TCS in-position and
Flash - - - - - Flash
working normally
Order Wire Card (OW)

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Functions

The OW card is used to implement the order wire function of the


system.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
continuation

• PTP, PMP, point-to-group, and point-to-the-entire line


• Support forced-insert call
• Support multi-party conference call mode in up to 28 order wire
directions
• Three 2-wire analog telephone interfaces, the first two of which
are order wire interfaces and the last one is TRK interface.
• Support five data interfaces, which can be configured as
RS232/RS422.
• F1 co-directional data interface function.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Types of Call

1. PTP S1S2S3

2. Point-to-group #888***

3. Forced insert #999111 (RSOH)


#999222 (MSOH)

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
OW Panel

1 Running Status Indicators


Card

Reset
2 Button

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Optical Line (OL) Card

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
OL16 Functional Diagram

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
OL Card General Functions

• Multiplexing low-speed signals into STM-N high-speed signals


• Receiving and sending STM-N line signal
• Implementing frame alignment, overhead extraction, alarm
detection, and overhead insertion at the transmitting side

• OL cards can be installed at the processing card slot. The optical


interface is provided on the panel of the board which uses an
LC/PC interface.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Types of OL Cards

• OL16 Single channel STM-16 OL card

• OL4 Single channel STM-4 OL card

• OL4x2 Dual-channel STM-4 OL card

• OL1x2 Dual-channel STM-1 OL card

• OL1x4 Four-channel STM-1 OL card

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
OL16 Card Panel

Card Running Status Indicators

Optical Interface Indicators Optical Transmitting Interface


Optical Receiving Interface

Laser Warning Label


Reset Button

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
OL1x4 Card Panels

Card Running Status Indicators

Optical Interface Indicators Optical Interface

Laser Warning Label


Reset Button

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
STM-1 Electrical Interface Unit

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Functional Diagram

The STM-1 electrical interface unit provides external STM-1 standard


electrical interfaces in 8 (or 4) directions and supports 1:N (N ≤ 4)
protection.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
STM-1 Electrical Card Subsystem

• LP1x4: 4-channel STM-1 line processing card


• LP1x8: 8-channel STM-1 line processing card
• ESS1x4: 4-channel STM-1 electrical interface switching card
• ESS1x8: 8-channel STM-1 electrical interface switching card
• BIE3: Bridge Interface card for STM-1e/E3/T3/FE

 Important Remark
Only the first port of LP1 supports DCC, line clock. And the first 4
ports support MSP 1+1 and overhead processing. MSP and 1:N
protection cannot be used together.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
STM-1 Electrical Unit 1:N Protection

• Two groups of 1:N (N≤4) protection can be realized in one


equipment.

• The protecting slot is fixed. When slot 1 is used as the


protecting slot, the working slots should be in 2~5, or when
slot 16 is used, the working slots should be in 12~15.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Configurations of STM-1 Electrical
Card

Service Card Configuration

8-channel STM-1 electrical interface service


processing LP1x8, ESS1x8

4-channel STM-1 electrical interface service


processing LP1x4, ESS1x4

8-channel STM-1 electrical interface service


processing with 1:N (N ≤ 4) protection LP1x8, ESS1x8 and BIE3

4-channel STM-1 electrical interface service


processing with 1:N (N ≤ 4) protection LP1x4, ESS1x4 and BIE3

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
STM-1 Electrical Unit Panels

Card
1
Running Status Indicators
Receiving/Transmitting Ports
2
3 Receiving/Transmitting
4
Indicator of Electrical
5 Interface
6

Indicator of Card Power-on


Reset
7 Button
Indicator of Card Switching

LP1×
×4 Panel ESS1×
×4 Panel
ZTE University univ.zte.com.cn
univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
E1 Tributary Subsystem

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Functional Diagram

The E1 tributary subsystem performs asynchronous mapping/de-


mapping function of PDH E1 electrical signals, and provides 1:N
tributary protection.

Time-
selection/serial-
conversion unit

processing unit

division Tributary

Interface unit
m apping unit
Mapping/de-
re-timing
Overhead/

cross-
Dual bus

unit
parallel

pointer

switch unit
STM-4 VC-4 E1
Tributary
Delay clock
cascading extraction
unit unit

Reference clock

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
E1 Tributary Subsystem

• EPE1x63 (75): Electrical Processor of E1×63 (75 Ω)


• ESE1x63: Electrical Interface Switching Card of E1×63 (75 Ω)
• EIE1x63: Electrical Interface of E1×63 (75 Ω)

• EPE1x63(120): Electrical Processor of E1×63 (120 Ω)


• EST1x63: Electrical Interface Switching Card of E1×63 (120
Ω)
• EIT1x63: Electrical Interface of E1×63 (120 Ω)

• BIE1: Bridge Interface Card of E1

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
E1 Tributary 1:N Protection

• One group of 1:N (N≤9) protection can be realized in one


equipment

• Any slot of 1~5 and 12~16 can be used as the protecting slot,
and the remaining nine slots can be the working slots

• 1:N protection of E1 service can be used together with the 1:N


protection of other services.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Configuration of the E1 Card

Card
Service
Configuration
63-channel E1 electrical interface (with 75 EPE1x63 (75) and
Ω interface) service processing EIE1x63
63-channel E1 electrical interface (with EPE1x63 (120) and
120 Ω interface) service processing EIT1x63
63-channel E1 electrical interface (with 75 EPE1x63 (75),
Ω interface) service processing with 1:N ESE1x63 and BIE1
(N ≤ 9) protection
63-channel E1 electrical interface (with EPE1x63 (120),
120 Ω interface) service processing with EST1x63 and BIE1
1:N (N ≤ 9) protection

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
E1 Tributary Card Panels

Card
1 Running Status Indicators

1E1 Interface

Reset
2
Button

EPE1 Panel EIE1x63 Panel


ZTE University univ.zte.com.cn
univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Optical Amplifier (OA) Card

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
OA Card Functions

• Extend the transmission distance through amplification of the


optical power of the 1550 nm wavelength, and provide the
transparent transmission channel for the optical signals. The
data rate falls into 2.5 Gbit/s, 622 Mbit/s and 155 Mbit/s.

• Depending on the position, the OA card maybe categorized as


OBA and OPA.

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.
Card Panel

Card Running Status Indicators

Receiving/Transmitting Optical Interface


Indicator for EDFA Optical Power Status

Laser Warning Label


Reset Button

ZTE University univ.zte.com.cn


univ.zte.com.cn
The information contained in the file is a sole property of ZTE Corporation. Any kind of disclosure without permission is prohibited.