'I Pm2-5 real-time measurement display

2 PM1.0 real-time measurement display


3. PM l0 real-time measurement display
4. Temperature real-time measurement display
5. Humidity real-time measurement display
6- AQI real-time estimated value display
Operating lnstruction for
PM 2.5 Laser Detector

1 Powersupply
DC:5V, MicroUSB interface
2. PM 2 5 measurement technique index
Range of measurement: 0-2048ug/m3
Accuracy display:'1 ug/m3
3- PM1.0 measurement technique index
Range of measurement: 0-2048ug/m3
Accuracy display: 1 ug/m'
4 PM10 measurement technique index
Range of measurement: 0-2048ug/m'
Accuracy display: I ug/m'
5. temperature measurement technique index
Range of measurement: 0-50?
Measurement accuGcy: t2'c Contrast Table forAlr Quallty
6. humidity msasurement technique index
Range of measurement: 20-90o/oRH PM2.5 concentration Grade of air quality
Measuremsnt accuracy: t5%RH
0-50 Good

50- 100 Moderate

f. instrument is connected to DCsV source and starts 100-1 50 Lightly Pollutsd


to test automatically, the value will be stable after ten
seconds. Users can obserue real-time value 1 50-200 Moderately Polluted
2 right button can changeoverscreen interface and
Heavily Polluted
200-300
acquire its real-time measurement value.
3. instrument breaks DCSV source, turns off 300+ Severely Polluted
automatically and stop testing