Data Sheet: The Configuration Is Inconsistent This Printout Is Possibly Incorrect

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Data sheet

The configuration is inconsistent; this printout is possibly


incorrect.

Customer item no.:


Communication dated: Number: ES 5736981
Doc. no.: Quick quote Item no.: 100
Quantity: 1 Date:
Page: 1 / 5

UPAS 200-075/07CC+UMA 200- 45/21G Version no.:

Operating data
Requested flow rate 50.00 m³/h Actual flow rate 50.00 m³/h
Requested developed head 160.00 m Dev. head without non-return 160.25 m
Pumped medium Water valve
Clean water Efficiency without non-return 77.4 %
_PumpedMediumText Not containing chemical and valve
mechanical substances which Power absorbed 28.12 kW
affect the materials Max. power on curve 37.68 kW
Ambient air temperature 20.0 °C Min. allow. flow for continuous 26.61 m³/h
Fluid temperature 20.0 °C stable operation
Fluid density 998 kg/m³ Min. allow. flow for short term 6.65 m³/h
operation
Shutoff head 178.19 m

Fluid viscosity 1.00 mm²/s Max. allow. flow rate 100.12 m³/h
Dev. head with non-return 160.25 m Design Single system 1 x 100 %
valve
Flow velocity around motor 0.2 m/s

Driver, accessories
Motor size 200D Type of current Three phase (3~)
Designed for operation with No Drinking water filling No
frequency inverter J2 Winding No
Motor speed 2918 rpm
Cable extension Connect extension cable in
Frequency 50 Hz
factory
Rated voltage 400 V
Short cable F4
Rated power P2 40.00 kW Short cable cross section 10.00 mm²
Available reserve 19.43 % Length of short cable 6.00 m
Rated current 81.4 A
Motor enclosure IP68 Extension cables designed for installation in open air, laid along
Cos phi at 4/4 load 0.82 a surface.
Motor efficiency at 4/4 load 86.2 % Cable shielding Without
Starting mode Direct-on-line starting Shroud type Without
Frequency inverter operation FI allowed
allowed

Design
Pump standard Submersible bore hole pumps Min. fluid level above pump 0.50 m
Design Close-coupled Non return valve With
Orientation Vertical Suction Strainer With
Design according to standard Drinking water acc. to ACS Valve plate drilled No
Discharge nominal dia. Please select Suction hood Without
Discharge norminal pressure Please select Bearing pedestal Without
Discharge flange drilled Please select Max. outside diameter 194.0 mm
according to standard Total length of unit 2539.0 mm
Wear ring Casing wear ring
Impeller diameter 131.0 mm
Data sheet
The configuration is inconsistent; this printout is possibly incorrect.

Customer item no.:


Communication dated: Number: ES 5736981
Doc. no.: Quick quote Item no.: 100
Quantity: 1 Date:
Page: 2 / 5

UPAS 200-075/07CC+UMA 200- 45/21G Version no.:

Materials Pump C - Materials Driver G


Suction casing (106) Stainless steel 1.4408 Valve body (751) Stainless steel 1.4408
Stage casing (108) Stainless steel 1.4408 Stator (81-59) Stainless steel 1.4301
Pump shaft (211) Duplex stainless steel 1.4462 Motor shaft (819) Duplex steel 1.4460
Clockwise impeller (232) Stainless steel 1.4408 Motor cable (824) CU-rubber
Casing wear ring (502) 1.4404-EPDM 80

Order documentation
The following documents will be supplied with the order: Technical data sheet
Operating manual Performance curve
General arrangement drawing Languages English, Spanish
Performance curve
The configuration is inconsistent; this printout is possibly incorrect.

Customer item no.:


Communication dated: Number: ES 5736981
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date:
Page: 3 / 5

UPAS 200-075/07CC+UMA 200- 45/21G Version no.:

Qmin
Total developed head

150

[m]

Qmax
100
ø132.0/130.0/136.0/20°/A09

0 20 [m³/h] 40 60 80 100

[m]
NPSH

0 20 [m³/h] 40 60 80 100
Efficiency

50

[%]

0
0 20 [m³/h] 40 60 80 100
40

[kW]
Power Input

30

20

0 20 [m³/h] 40 60 80 100
Flow

Curve data
Speed of rotation 2945 rpm Dev. head without non- 160.25 m
Fluid density 998 kg/m³ return valve
Viscosity 1.00 mm²/s Efficiency without non-return 77.4 %
Flow rate 50.00 m³/h valve
Requested flow rate 50.00 m³/h Power absorbed 28.12 kW
Requested developed head 160.00 m NPSH required 3.03 m
Curve number K3400.52.29/St3 SS/3
Effective impeller diameter 131.0 mm
Installation plan
The configuration is inconsistent; this printout is possibly
incorrect.

Customer item no.:


Communication dated: Number: ES 5736981
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date:
Page: 4 / 5

UPAS 200-075/07CC+UMA 200- 45/21G Version no.:

194

Please select

1309

2539

Drawing is not to scale Dimensions in mm


Installation plan
The configuration is inconsistent; this printout is possibly incorrect.

Customer item no.:


Communication dated: Number: ES 5736981
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date:
Page: 5 / 5

UPAS 200-075/07CC+UMA 200- 45/21G Version no.:

Motor Connections
Motor manufacturer KSB Discharge nominal size DN2 Please select / Please select
Motor size 200D Rated pressure disch. Please select
Motor power 40.00 kW
Number of poles 2
Speed of rotation 2918 rpm
Weight net
shroud 0 kg
Note: The dimensions shown Pump 93 kg
reflect the actual stage Motor, cable 156 kg
number. The drawing is Total 249 kg
only symbolic.
Connect pipes without stress or strain! For auxiliary connections see
separate drawing.

You might also like