SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.

: LCS1604251969S-1

Test item particulars:


Lamp cap ………………………….….……..: GU10
Lamp identification…………………….....….: LED Lamp
Commission received form .………............: Same as applicant
Electrical safety class .………………....…..: --
IP number ………….. …..……….…….…....: IP20
Test case verdicts
Test case does not apply to the test object : N (N/A)
Test item does meet the requirement …….: P(Pass)
Test item does not meet the requirement ..: F(Fail)
Testing
Date of receipt of test item ………………...: April 12, 2016
Date(s) of performance of test …………….: April 12, 2016 – April 27, 2016
General remarks

This report shall not be reproduced except in full without the written approval of the testing laboratory.

The test results presented in this report relate only to the item tested.

"(see remark #)" refers to a remark appended to the report.

"(see Annex #)" refers to an annex appended to the report.

Throughout this report a comma is used as the decimal separator.

Modified Information

Version Report No. Revision Data Summary


V1.0 LCS1604251969S / Original Version
V1.0 LCS1604251969S-1 August 02, 2016 Update Address

Remarks

1. All Models are similar except power, All test are conducted on model G NEP-GU100100761.

2. The laboratory ambient for testing: 22.0-28.0℃, 60%-73%R.H.

3. The report includes: Attachment No. 1: 2 pages report of product photos.

Version: V1.0 Page 2 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

Copy of marking plate

LED Spot Light CHINT


Model: G NEP-GU100100761
Rating: 220-240Vac, 50/60Hz, 7W

MADE IN CHINA

All Labels are similar except model name and rating.

Label of testing

Rubbing for 15 s with a piece of cloth soaked with water. And a further 15 s with a piece of cloth soaked
with petroleum.

Model List

Model Rarting Lamp cap


G NEP-GU100100331 220-240Vac, 50/60Hz, 3W GU10
G NEP-GU100100341 220-240Vac, 50/60Hz, 3W GU10
G NEP-GU100100361 220-240Vac, 50/60Hz, 3W GU10
G NEP-GU100100531 220-240Vac, 50/60Hz, 5W GU10
G NEP-GU100100541 220-240Vac, 50/60Hz, 5W GU10
G NEP-GU100100561 220-240Vac, 50/60Hz, 5W GU10
G NEP-GU100100731 220-240Vac, 50/60Hz, 7W GU10
G NEP-GU100100741 220-240Vac, 50/60Hz, 7W GU10
G NEP-GU100100761 220-240Vac, 50/60Hz, 7W GU10
G NEP-MR160100331 220-240Vac, 50/60Hz, 3W MR16
G NEP-MR160100361 220-240Vac, 50/60Hz, 3W MR16
G NEP-MR160100531 220-240Vac, 50/60Hz, 5W MR16
G NEP-MR160100561 220-240Vac, 50/60Hz, 5W MR16
G NEP-MR160100731 220-240Vac, 50/60Hz, 7W MR16
G NEP-MR160100761 220-240Vac, 50/60Hz, 7W MR16

Version: V1.0 Page 3 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

4 GENERAL REQUIREMENTS AND GENERAL TEST REQUIREMENTS P


4.1 The lamps shall be so designed and P
constructed that in normal use they function
reliably and cause no danger to the user or
surroundings.
4.2 Self-ballasted LED-lamps are non- P
repairable, factory-sealed units. They shall
normally not be opened for any tests. In the
case of doubt based on the inspection of the
lamp and the examination of the circuit
diagram, and in agreement with the
manufacturer or responsible vendor, either
the output terminals shall be short-circuited
or, in agreement with the manufacturer,
lamps specially prepared so that a fault
condition can be simulated shall be
submitted for testing
4.3 In general, all tests are carried out on each P
type of lamp or, where a range of similar
lamps is involved, for each wattage in the
range or on a representative selection from
the range, as agreed with the manufacturer.
4.4 When the lamp fails safely during one of the P
tests, it is replaced, provided that no fire,
smoke or flammable gas is produced.

5 MARKING P
5.1 1) Mark of origin P
2) Rated voltage/voltage range (V) 220-240Vac P
3) Rated input (W) See marking P
4) Rated frequency (Hz) 50/60Hz P
5.2 1) Lamp current (A) P
2) The mechanical stress caused by the No so higher weight N
weight of the lamp in the luminaire
3) Other things which have effect on the P
operation

5) not suitable for use under dust and P


moisture

5.3 1) Presence and legibility of the marking by P


visual inspection

Version: V1.0 Page 4 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

2) The durability of the marking is checked After rubbing test, the marking P
by rubbing lightly with water and hexane for was still legible.
15s
3) Availability of information by visual P
inspection

6. INTERCHANGEABILITY P
6.1 Interchange ability shall be ensured by the The caps is in accordance P
use of caps in accordance with IEC with EN Publication 60061-1
Publication 60061-1and 60061-3
6.2 Bending moment, mass and imparted by P
the lamp at the lamp holder
B15d: N
Cap sheet no. from IEC 60061-1 7004-11 N
Gauge sheet no. from IEC 60061-3 7006-10 and 7006-11 N
Bending mounting N
Masses N
B 22d: N
Cap sheet no. from IEC 60061-1 7004-10 N

Gauge sheet no. from IEC 60061-3 7006-4A, 7006-4B N

Bending mounting N

Masses N

E11: N

Cap sheet no. from IEC 60061-1 7004-6 N

Gauge sheet no. from IEC 60061-3 7006-6 N

Bending mounting N

Masses N

E12: N

Cap sheet no. from IEC 60061-1 7004-28 N

7006-27H, 7006-27J, 7006- N


Gauge sheet no. from IEC 60061-3
28C, 7006-32
Bending mounting N

Masses N

E14: N

Cap sheet no. from IEC 60061-1 7004-23 N

Version: V1.0 Page 5 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

7006-27F, 7006-28B, 7006- N


Gauge sheet no. from IEC 60061-3
28F, 7006-26D
Bending mounting N

Masses N

E17: N

Cap sheet no. from IEC 60061-1 7004-26 N

7006-27K, 7006-28F, 7006- N


Gauge sheet no. from IEC 60061-3
26D
Bending mounting N

Masses N

E26: 7004-21A N

Cap sheet no. from IEC 60061-1 7006-27D, 7006-27E N

Gauge sheet no. from IEC 60061-3 N

Bending mounting N

Masses N

E 27: N
Cap sheet no. from IEC 60061-1 7004-21 N
7006-27B, 7006-28A, 7006- N
Gauge sheet no. from IEC 60061-3
27C, 7006-50
Bending mounting N
Masses N
E39: N
E40 N
GU10: P
Cap sheet no. from IEC 60061-1 7004-121 P
Gauge sheet no. from IEC 60061-3 7006-121 P
Bending mounting P
Masses P
GZ10: N
Cap sheet no. from IEC 60061-1 7004-120 N
Gauge sheet no. from IEC 60061-3 7006-120 N
Bending mounting N
Masses N
GX53: N
Cap sheet no. from IEC 60061-1 7004-142 N
Version: V1.0 Page 6 of 13
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

7006-142, 7006-142D, 7006- N


Gauge sheet no. from IEC 60061-3
142E, 7006-142F
Bending mounting N
Masses N

7. PROTECTION AGAINST ELECTRIC SHOCK P


Lamps shall be so constructed that no Can not access internal metal P
internal metal parts or live parts are parts or live parts.
accessible, when the lamp is installed in a
prescribed lampholder. Compliance is
checked by means of the standard test
finger with force of 10N.
Edison screw caps compliance with gauge N
IEC60061-3, sheet 7006-51A for E27caps
And sheet 7006-55 for E14 caps N
B22 or B15 caps compliances with normal N
incandescent lamps
Lamps with B22, B15, GU10 or GZ10 caps P
are subject to the same requirements as
normal incandescent lamps with this cap.
External metal parts shall be so designed P
that live parts are not accessible

8. INSULATION RESISTANCE AND ELECTRIC STRENGTH AFTER P


HUMIDITY TREATMENT
8.1 General P
Insulation resistance and electric strength P
shall be adequate between live parts of the
lamp and accessible parts of the lamp.
8.2 Insulation resistance P
Lamps shall storage 48 h at a 91-95 % 93%, 25C 48h P
relative humidity and at 20-30 C.
After storage, Insulation resistance with 500 >100 M P
V d.c., required  4 M.
8.3 Electric strength P
SELV: N
- between current-carrying parts of different N
polarity...................................................... :
- between current-carrying parts and metal N
parts......................................................... :
Other than SELV: P
Version: V1.0 Page 7 of 13
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

- between live parts of different polarity ... : 1480Vac, 1min, no damage P


- between live parts and metal parts......... : 2960Vac, 1min, no damage P
No flashover or breakdown shall occur P
during the test. Measurements shall be
carried out in the humidity cabinet.

9. MECHANICAL STRENGTH P
9.1 Requirments P
9.2 Test
9.2.1 Torsion resistance of unused lamps P
The mechanical strength of connection P
between the cap and the bulb/part of the
lamp is checked by the torque of 3 Nm.
- B15d ……………………...…….1.15 Nm N
- B22d ………………………...……..3.0 Nm N
- E11 ………………..……...........….0.8 Nm N
- E12 …………………………………0.8 Nm N
- E14 ………………………..…...…1.15 Nm N
- E17 …………………………………1.5 Nm N
-E26 and E26d……………..………3.0 Nm N
-E27…………………………..………3.0 Nm N
-E39…………………………..………5.0 Nm N
-E40…………………………..………5.0 Nm N
- GU10 ……………………………………….: P
- GZ10 ……………………………………….: N
-GX53…………………………...…………...: N
Torque increased continuously from zero to P
specified value
Uncemented caps; relative movement P
between cap and bulb does not exceed 10
After mechanical strength test sample P
complies requirement of accessibility
9.2.2 Torsion resistance of lamps after a defined P
time of usage
9.2.3 Externally applied axial pull and bending P
moment
9.3 After 9.2 test, comply clause 8 P

Version: V1.0 Page 8 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

9.4 Axial strength of Edison caps P


-E11………………………………………….: 7006-6-1 N
-E12………………………………………….: 7006-27H-1 N
-E14…………………….………………80N: 7006-27F-1 N
-E26 or E26d…………………….….120N: 7006-27B-1 N
-E27……………………………….….120N: 7006-27B-1 N
-E39………………………………………..: 7006-27B-1 N
-E40………………………………………..: 7006-27-7 N

10. CAP TEMPERATURE TEST See the appended table 3 P


The Cap temperature rise not exceed 120K P

11. RESISTANCE TO HEAT P


External parts of insulating material P
providing protection against electric shock,
and parts of insulating material retaining
live parts in position, ball pressure test:
Part tested; temperature (C); Plastic enclosure: 125℃, P
diameter of impression ( 2 mm)…............: 1.2mm
Part tested; temperature (C); Translucent cover: 80℃, P
diameter of impression ( 2 mm)…............: 1.1mm
Part tested; temperature (C); PCB: 125℃, 0.6mm P
diameter of impression ( 2 mm)…............:
Part tested; temperature (C); Bobbin of transformer: 125℃, P
diameter of impression ( 2 mm)…............: 1.0mm

12. RESISTANCE TO FLAME AND IGNITION P


Glow-wire test P
Part tested; temperature (C); Plastic enclosure, translucent P
cover, PCB, Bobbin of
transformer, 650℃, no
burning
No visible flame and no sustained glowing P
Flames and glowing, extinguish within 30s: N
No ignition of the tissue paper P

13. FAULT CONDITIONS --


13.1 General requirement P

Version: V1.0 Page 9 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

Lamps shall not impair safety when P


operated under fault conditions which may
occur during the intended use.
13.2 Test conditions No damage after test P
Opening or bridging component See the appended table 2 P
Circuit diagram show fault condition See the appended table 2 P
Short-circuit components See the appended table 2 P
13.3 Compliance P
Test for a further 8h, not catch fire, produce P
flammable gases or smoke and live part
shall not become accessible
After test in 13.2 to 13.5. insulation
resistance test with 1000Vdc:

14. CREEPAGE DISTANCES AND See the appended table 4 P


CLEARANCES

15. ABNORMAL OPERATION P


Non-dimmable self-ballasted lamps on a P
dimmer or an electronic switch
Test for a further 8h, not catch fire, produce P
flammable gases or smoke and live part
shall not become accessible

16. TEST CONDATIONS FOR DIMMABLE P


LAMPS
Setting for clause 10 and clause 17 N

17. PHOTOBIOLOGICAL SAFETY P


17.1 UV radition N
The ultraviolet hazard afficacy not exceed N
2Mw/klm
17.2 Blue light hazard P
Comply with IEC TR 62778 P
17.3 Infrared radiation N

18. INGRESS PROTECTION N


18.1 Requirments N

Version: V1.0 Page 10 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1

IEC 62560
Clause Requirement - Test Result - Remark Verdict

18.2 Test N
Comply with Clause 9.2 of IEC 60598-1 N

19. INFORMATION FOR LUMINAIRE DESIGN N

ANNEX A INFORMATION FOR LUMINAIRE DESIGN --

Version: V1.0 Page 11 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1
Tables

Table 1: Components --
object/part Code manufacturer/trademark type/model technical data standard mark(s) of
No. conformity
Fuse B AEM MF2410F2.00 250V, T2A IEC/EN VDE
COMPONENTS(SUZHOU) 0TM 60127-4 40034853
CO,LTD
LED PCB B SHENZHEN CHENGZHIYI CZY-R001 90℃, V-0 UL 796 E354470
PCB CO LTD UL94
PCB Board B GOLDENMAX FR-4.0 V-0;130℃ UL796 UL
INTERNATIONAL UL94 E224772
TECHNOLOGY LTD
Plastic B BAYER 6487+(z)(f1) V-0, 125℃ UL746 E41613
enclosure MATERIALSCIENCE AG
Translucent B BAYER 1899+(z) V-0, 80℃ UL746 E41613
cover MATERIALSCIENCE AG
Internal wire B SHENZHEN JINRUIHUA 1015 22AWG, 300V, UL758 UL
o
105 C E316944
WIRE & CABLE CO LTD
Bobbin of B CHANG CHUN PLASTICS UL
T375J 94V-0,150°C UL 94
transformer CO LTD E59481
Magnetic coil B UL
SHENZHEN CHENGWEI E227475
of transformer 2UEW 130℃ UL 1446
INDUSTRY CO LTD

Insulation B JINGJIANG YAHUA UL


tape of PRESSURE SENSITIVE WF 130℃ UL 510
E165111
transformer GLUE CO LTD
Varnish of B DOW CORNING CN-8760 130℃ UL1446 E251343
transformer (SHANGHAI) CO LTD

The codes above have the following meaning:


A - The component is replaceable with another one, also certified, with equivalent characteristics
B - The component is replaceable if authorised by the test house
C - Integrated component tested together with the appliance
D - Alternative component

Table 2: Tests of fault conditions --


Part Voltage Simulated Test result Hazard
fault
Output 240V~ s-c Shut down, recoverable, no damage No
U1(1-8) 240V~ s-c Shut down, recoverable, no damage No
C1 240V~ s-c Fuse opened. No hazard, No damage. No

Version: V1.0 Page 12 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1604251969S-1
Tables

C3 240V~ s-c Shut down, recoverable, no damage No


D2 240V~ s-c Fuse opened. No hazard, No damage. No
BD1 240V~ s-c Fuse opened. No hazard, No damage. No
NOTE:S-C; short circuit ; O-C; open circuit

Table 3: Temperature measurements --


Type reference ………………………………….…......: G NEP- --
GU100100761
Lamp used ………………………………….……........: LED Lamp --
Lamp control gear used…………………..………......: Integral ballast --
Mounting position of luminaire……………..…………: See specification --
Supply wattage (W) ………………………………..….: 7.6W --
Supply current (A) ………………………..……..…….: --
Calculated power factor………………………………..: --
Table: measured temperatures corrected for ta = 25℃: --
- test 1: rated voltage……………………………..……: See below P
Through wiring or looping-in wiring loaded by a --- N
current of A during the test …..................................:
Clause 10 – Temperature test
Temperature(℃) of part
Test under 220V~ Test under 240V~ Limit (℃)
E27 Lamp cap -- 62.3 145
LED PCB -- 88.7 90
Translucent cover -- 42.8 Ref
Plastic enclosure, inside, near
-- 68.0 Ref.
LED
Internal wire -- 76.2 105
C1 -- 98.6 105
C3 -- 95.1 105
Winding of transformer T1 -- 105.8 130
PCB under T1 -- 97.1 130
Ambient -- 25.0 --

Table 4: CREEPAGE DISTANCES AND CLEARANCES --


Parts Voltage Measurement Measurement Limit (Cr.) Limit (Cl.)
(Cr.) (Cl.)
opposite polarity (L/N) 240V~ 3.1mm 3.1mm 2.5mm 1.5mm
Live part and accessible part 240V~ 5.5mm 5.5mm 5.0mm 3.0mm

Version: V1.0 Page 13 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO: LCS1604251969S-1

ATTACHMENT 1
Photo Documentation

View:
Model:
G NEP-
GU100100761
[X]General
[ ]Front
[ ]Rear
[ ]Internal
[ ]Top
[ ]Bottom
[ ]PWB

Figure 1

View:

[ ]General
[ ]Front
[ ]Rear
[X]Internal
[ ]Top
[ ]Bottom
[ ]PWB

Figure 2

Version: V1.0 Page 1 of 2


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO: LCS1604251969S-1

ATTACHMENT 1
Photo Documentation

View:
[X]General
[ ]Front
[ ]Rear
[ ]Internal
[ ]Top
[ ]Bottom
[ ]PWB

Figure 3

View:

[ ]General
[ ]Front
[ ]Rear
[X]Internal
[ ]Top
[ ]Bottom
[ ]PWB

Figure 4

Version: V1.0 Page 2 of 2

You might also like