Project: TIMOR Prepared KMN Document No.

: XXX

Job No. : Checked VAM Rev No. : 00

Teflon Approved VAM Date : 29.08.20


Design of Teflon : 300
TRIAL SIZE
a = 300 mm
b = 300 mm 300

Max. design force compression (Factored) = 850 kN


Compressive strength of Teflon = 24.1 N/mm2 (PTFE)
Design strength of PTFE = 24.1/1.67 = 14 N/mm2 (Assumed)
Area required = 58900 mm2
Area provided = 90000 mm2 > 58900 mm2
Ratio = 0.65 HENCE OK