CADD-Legacy® Pump Specifications (nominal)

CADD-Legacy® PCA CADD-Legacy® 1 CADD-Legacy® PLUS


Reorder Numbers 21-6300 21-6400 21-6500
Delivery Modes Continuous, Continuous Continuous, Intermittent
Demand Dose,
Clinician Bolus
Modes can be used independently or in combination
Delivery Routes Intravenous, Intra-arterial, Intravenous, Intra-arterial, Intravenous, Intra-arterial,
Subcutaneous, Intraperitoneal, Subcutaneous, Intraperitoneal, Subcutaneous, Intraperitoneal,
Epidural, Intrathecal Epidural, Intrathecal Epidural, Intrathecal
Programming
Programming Units ml, mg, mcg ml ml
Reservoir Volume
Drug Concentration
1 ml–9,999 ml or not in use
0.1-100 mg/ml, 1-500 mcg/ml
1 ml–9,999 ml or not in use 1 ml–9,999 ml or not in use
CADD-Legacy® Ambulatory Infusion Pumps
Continuous Rate 0-50 ml/hr, 0-5,000 mg/hr, 1–3,000 ml/24 hr 0.1–125 ml/hr
0-25,000 mcg/hr†
Intermittent Rate 0-125 ml/hr
KVO Rate 0-125 ml/hr
Dose Volume Demand Dose 0.1-1,000 ml
0-9.9 ml, 0-990 mg, 0-4,950 mcg†
Clinician Bolus
0-20 ml, 0-2,000 mg, 0-10,000 mcg†
Dose Duration 1 min-24 hr
Dose Cycle 10 min-96 hr
Dose Starts In Immediate or 1 min-96 hr
Demand Dose Lockout 5 min-24 hr
Demand Doses per Hour 1-12
Reporting
Reservoir Volume 0-9,999 ml (ml only) 0-9,999 ml 0-9,999 ml
Given (Volume Delivered) 0-99,999.95 ml 0-99,999.95 ml 0-99,999.95 ml
Dose Remaining 1 min-24 hr
Doses Given 0-999
Doses Attempted 0-999
†Depending on concentration

All CADD-Legacy® Pumps Accessories for All CADD-Legacy® Pumps


Event Memory AC Adapter Reorder No. 21-6202
Number of Events Last 1000 in pump’s history Carrying Pouches 50/100ml (Single use) Reorder No. 21-6161
Download Capability Direct or remote (modem) connection to PC Carrying Pouches 250/500ml (Single use) Reorder No. 21-6163
Software Compatibility CADD-DIPLOMAT® PC Communications Carrying Pouches 50/100ml (Reusable) Reorder No. 21-6260
Safety Features Carrying Pouches 250/500ml (Reusable) Reorder No. 21-6265
Air-in-line Detector High, Low, Off Pump Modem Communications Kit Reorder No. 21-6270
Upstream Occlusion Sensor On, Off Interface Cable/Null Modem Cable Reorder No. 21-6250
Downstream Occlusion Sensor On
Cassette Detector On Accessories for CADD-Legacy® PCA Pumps Only
Lock Levels 3 Remote Dose Cord Reorder No. 21-6220
Other Specifications Polemount Bracket Adapter Reorder No. 21-6210
Size 1.6 x 3.8 x 4.4 in (4.1 x 9.5 x 11.2 cm) Security Shell Adapter Reorder No. 21-6212
Weight 13.8 oz (392 grams)
Power Source 2 AA alkaline batteries, AC adapter
Accuracy + 6%, nominal
Warranty 1 year

Please read the Operator’s Manual supplied with the product for detailed instructions, warnings, and cautions.
Designed for your patients’
Smiths Medical ASD, Inc. EC Authorized Representative Australian Representative
St. Paul, MN 55112, USA Smiths Medical International Ltd.
TN25 4BF, UK
Smiths Medical Australasia Pty. Ltd.
Brisbane, QLD 4113, Australia
ambulatory infusion needs
Phone: 1-214-618-0218
Toll-Free USA: 1-800-258-5361 Phone: +44 (0) 1233 722100 Phone: +61 (0) 7 3340 1300

www.smiths-medical.com
Find your local contact information at www.smiths-medical.com/customer-support
Smiths Medical is part of the global technology business Smiths Group plc. Product(s) described may not be licensed or available
for sale in all countries. CADD-Legacy, CADD, the Medication Cassette reservoir design, and the Smiths Medical and CADD design
marks are trademarks of Smiths Medical. The symbol ® indicates the trademark is registered in the U.S. Patent and Trademark
Office and certain other countries. Rx only. ©2011 Smiths Medical. All rights reserved. 9/11 IN19870
CADD-Legacy®
ambulatory infusion pumps A choice of infusion pumps
Smiths Medical offers you a choice of both
CADD-Legacy® pumps are designed to provide: CADD-Legacy® single-therapy infusion pumps
and other CADD® pumps for multi-therapy
• CADD® pump reliability delivery, so you can select the CADD® pump
• Single-therapy pump simplicity that best meets your needs.
• Enhanced programming flexibility
• Ease of use

CADD-Legacy® PLUS
ambulatory infusion pump
CADD-Legacy PCA ®
for intermittent or continuous therapies
ambulatory infusion pump Infusion rates up to 125 milliliters
for pain management therapies per hour and dose volumes up to
1,000 milliliters can accommodate
Convenient programming in millili-
high-rate, high-volume therapies.
CADD-Legacy 1 ® ters, milligrams or micrograms and
expanded concentration ranges. Longer delayed start time and
ambulatory infusion pump
expanded dosing parameters provide
for continuous infusion therapies New display messages, such as added flexibility in meeting complex
“DOSE” when a demand dose is therapy requirements.
Infusion rates from 1 to 3,000 ml/day being delivered, are designed to give
can meet the requirements of a wide easy-to-understand information to Internal clock designed to keep
range of continuous delivery protocols. the patient. dosing on schedule.

CADD-Legacy® pump features


Easy to read display On/off key Flexibility
Provides information for programming adjustments Allows pump to be placed in low-power state and Significantly increased programming ranges
and troubleshooting. is designed to save battery life. are designed to provide greater flexibility in
Cassette detection Event memory meeting a wider range of delivery requirements.
Designed to detect cassette attachment. The last 1000 events in the pump’s history can Specificity
Occlusion detection be downloaded. Smaller unit increments may help refine many
Upstream and downstream occlusion sensors Reliability programming and reporting parameters.
alert the patient and clinician if interruption of CADD® pump reliability and durability can mean Event memory
fluid delivery occurs. less down time and fewer interruptions to therapy. The last 1000 events in the pump’s memory can
Air-in-line detection Simplicity be downloaded to a PC to assist in patient
Off, High- and Low-sensitivity settings is designed Enhanced keypad and message display capabilities management, troubleshooting and documentation.
to alert the patient and clinician if air is present in are designed to make programming and Safety
the administration set tubing. troubleshooting easy. Built-in safety features are designed to alert
the user to prevent improper delivery.
CADD-Legacy®
ambulatory infusion pumps A choice of infusion pumps
Smiths Medical offers you a choice of both
CADD-Legacy® pumps are designed to provide: CADD-Legacy® single-therapy infusion pumps
and other CADD® pumps for multi-therapy
• CADD® pump reliability delivery, so you can select the CADD® pump
• Single-therapy pump simplicity that best meets your needs.
• Enhanced programming flexibility
• Ease of use

CADD-Legacy® PLUS
ambulatory infusion pump
CADD-Legacy PCA ®
for intermittent or continuous therapies
ambulatory infusion pump Infusion rates up to 125 milliliters
for pain management therapies per hour and dose volumes up to
1,000 milliliters can accommodate
Convenient programming in millili-
high-rate, high-volume therapies.
CADD-Legacy 1 ® ters, milligrams or micrograms and
expanded concentration ranges. Longer delayed start time and
ambulatory infusion pump
expanded dosing parameters provide
for continuous infusion therapies New display messages, such as added flexibility in meeting complex
“DOSE” when a demand dose is therapy requirements.
Infusion rates from 1 to 3,000 ml/day being delivered, are designed to give
can meet the requirements of a wide easy-to-understand information to Internal clock designed to keep
range of continuous delivery protocols. the patient. dosing on schedule.

CADD-Legacy® pump features


Easy to read display On/off key Flexibility
Provides information for programming adjustments Allows pump to be placed in low-power state and Significantly increased programming ranges
and troubleshooting. is designed to save battery life. are designed to provide greater flexibility in
Cassette detection Event memory meeting a wider range of delivery requirements.
Designed to detect cassette attachment. The last 1000 events in the pump’s history can Specificity
Occlusion detection be downloaded. Smaller unit increments may help refine many
Upstream and downstream occlusion sensors Reliability programming and reporting parameters.
alert the patient and clinician if interruption of CADD® pump reliability and durability can mean Event memory
fluid delivery occurs. less down time and fewer interruptions to therapy. The last 1000 events in the pump’s memory can
Air-in-line detection Simplicity be downloaded to a PC to assist in patient
Off, High- and Low-sensitivity settings is designed Enhanced keypad and message display capabilities management, troubleshooting and documentation.
to alert the patient and clinician if air is present in are designed to make programming and Safety
the administration set tubing. troubleshooting easy. Built-in safety features are designed to alert
the user to prevent improper delivery.
CADD-Legacy® Pump Specifications (nominal)
CADD-Legacy® PCA CADD-Legacy® 1 CADD-Legacy® PLUS
Reorder Numbers 21-6300 21-6400 21-6500
Delivery Modes Continuous, Continuous Continuous, Intermittent
Demand Dose,
Clinician Bolus
Modes can be used independently or in combination
Delivery Routes Intravenous, Intra-arterial, Intravenous, Intra-arterial, Intravenous, Intra-arterial,
Subcutaneous, Intraperitoneal, Subcutaneous, Intraperitoneal, Subcutaneous, Intraperitoneal,
Epidural, Intrathecal Epidural, Intrathecal Epidural, Intrathecal
Programming
Programming Units ml, mg, mcg ml ml
Reservoir Volume
Drug Concentration
1 ml–9,999 ml or not in use
0.1-100 mg/ml, 1-500 mcg/ml
1 ml–9,999 ml or not in use 1 ml–9,999 ml or not in use
CADD-Legacy® Ambulatory Infusion Pumps
Continuous Rate 0-50 ml/hr, 0-5,000 mg/hr, 1–3,000 ml/24 hr 0.1–125 ml/hr
0-25,000 mcg/hr†
Intermittent Rate 0-125 ml/hr
KVO Rate 0-125 ml/hr
Dose Volume Demand Dose 0.1-1,000 ml
0-9.9 ml, 0-990 mg, 0-4,950 mcg†
Clinician Bolus
0-20 ml, 0-2,000 mg, 0-10,000 mcg†
Dose Duration 1 min-24 hr
Dose Cycle 10 min-96 hr
Dose Starts In Immediate or 1 min-96 hr
Demand Dose Lockout 5 min-24 hr
Demand Doses per Hour 1-12
Reporting
Reservoir Volume 0-9,999 ml (ml only) 0-9,999 ml 0-9,999 ml
Given (Volume Delivered) 0-99,999.95 ml 0-99,999.95 ml 0-99,999.95 ml
Dose Remaining 1 min-24 hr
Doses Given 0-999
Doses Attempted 0-999
†Depending on concentration

All CADD-Legacy® Pumps Accessories for All CADD-Legacy® Pumps


Event Memory AC Adapter Reorder No. 21-6202
Number of Events Last 1000 in pump’s history Carrying Pouches 50/100ml (Single use) Reorder No. 21-6161
Download Capability Direct or remote (modem) connection to PC Carrying Pouches 250/500ml (Single use) Reorder No. 21-6163
Software Compatibility CADD-DIPLOMAT® PC Communications Carrying Pouches 50/100ml (Reusable) Reorder No. 21-6260
Safety Features Carrying Pouches 250/500ml (Reusable) Reorder No. 21-6265
Air-in-line Detector High, Low, Off Pump Modem Communications Kit Reorder No. 21-6270
Upstream Occlusion Sensor On, Off Interface Cable/Null Modem Cable Reorder No. 21-6250
Downstream Occlusion Sensor On
Cassette Detector On Accessories for CADD-Legacy® PCA Pumps Only
Lock Levels 3 Remote Dose Cord Reorder No. 21-6220
Other Specifications Polemount Bracket Adapter Reorder No. 21-6210
Size 1.6 x 3.8 x 4.4 in (4.1 x 9.5 x 11.2 cm) Security Shell Adapter Reorder No. 21-6212
Weight 13.8 oz (392 grams)
Power Source 2 AA alkaline batteries, AC adapter
Accuracy + 6%, nominal
Warranty 1 year

Please read the Operator’s Manual supplied with the product for detailed instructions, warnings, and cautions.
Designed for your patients’
Smiths Medical ASD, Inc. EC Authorized Representative Australian Representative
St. Paul, MN 55112, USA Smiths Medical International Ltd.
TN25 4BF, UK
Smiths Medical Australasia Pty. Ltd.
Brisbane, QLD 4113, Australia
ambulatory infusion needs
Phone: 1-214-618-0218
Toll-Free USA: 1-800-258-5361 Phone: +44 (0) 1233 722100 Phone: +61 (0) 7 3340 1300

www.smiths-medical.com
Find your local contact information at www.smiths-medical.com/customer-support
Smiths Medical is part of the global technology business Smiths Group plc. Product(s) described may not be licensed or available
for sale in all countries. CADD-Legacy, CADD, the Medication Cassette reservoir design, and the Smiths Medical and CADD design
marks are trademarks of Smiths Medical. The symbol ® indicates the trademark is registered in the U.S. Patent and Trademark
Office and certain other countries. Rx only. ©2011 Smiths Medical. All rights reserved. 9/11 IN19870