Complete Plans For A Timbre Frame House

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

35700

ERF XXXX 5321 ABARCHITECTURE.CO.ZA

STAMPS

EXST. CWC
+72 72 393 1367

2000
2000

4M BUILDING LINE
2M BUILDING LINE
COPYRIGHT OF THIS DRAWING IS VESTED IN THE DRAWER

2M BUILDING LINE
UNAUTHORISED COPYING IS NOT PERMITTED.
ALL DIMENSIONS SHOULD BE SITE CHECKED BEFORE
COMMENCING WORK. DO NOT SCALE FROM THIS DRAWING, IF
IN DOUBT PLEASE ASK FOR CLARIFICATION

1800
Corrugated polycarbonate sheeting
FREE HANGING LAMP L NOTES:
HOLDER BLACK
WALLS:

5 TEMPLEMAN DRIVE
NYLON 10MM WITH BEDROOM 1
CORD CENTRED To be constructed in accordance with part K of SANS 10400 of 2010.
13 m² STANDARD EUROLUX
BETWEEN EXPOSED External walls: timber-framed walls and the anchoring of roofs to wall shall be
FIXED DOWNLIGHTER
RAFTERS - 2400 in accordance with SANS10082. All timber to be preservative treated in
PLACED IN ISOBOARD
AFFL accordance with SANS 10005. Siding: min 0.5mm thick hot dipped galvanized
ERF 5220 BETWEEN RAFTERS

18893
Corrugated metal sheeting corrugated siding or simlar approved, fixed strictly according to product
specfications, on sisilation or similar approved on undertile / waterproof
underlay membrane on 12mm plywood on 114x38mm timber studs @

ERF XXXX
600mm cc. on 114x38mm foot plate. 114x38mm noggings @ 900mm vertical
cc staggered to engg. spec. Inside wall finish layer to be 12.5mm plasterboard
skimmed and painted - colour TBC. All walls to have 100mm isotherm /

30000

30000
rockwool insulation
L
Interior walls:
500 12.5mm plasterboard skimmed and finished in super acrylic or equal wall
coating - colour TBC, on 114x38mm timber studs @ 600mm cc. on

830
EXISTING WC
SH
HWB 114x38mm foot plate. 114x38mm noggings @ 900mm vertical cc staggered.
PAVED Corrugated polycarb sheeting Bathroom walls to nutec board and according to bathroom elevations
DRIVEWAY BATHROOM 1 ROOFS:
2
4 m² Lean to Roof: Roof covering to be Clean Colorbond Thermatech - colour
A102 "african white" metal roof sheeting fixed strictly in accordance with
Eurolux LED Day/Night BATHROOM 2
1000 SH manufacturers spec. Roof on 50x50mm battens on sisalation (min. 25mm air
sensor Blister flood light 4 m² HWB
5500 WC gap on either side) on 76x228mm Vacsol Azure treated SA Pine rafters at
{3D} Copy 2 TO MUNICIPAL CONNECTION
max. 1000mm centres spec. Rafter ends on 38x114mm timber wallplate or to

10 engg. spec. All work to be carried out by specialists and to engg. spec.
Fascias to be 20mmx215mm therma treated pine painted with a matt clear
coat. Beams shall comply with the requirements of SANS 1460 and shall be
NEW 20w LED motion
L of grade 5 or higher.
CARPORT sensor flood light
1 40mm IsoPine IsoBoard tongue and groove insulation to be fitted between

5000
rafters
A102 FLOORS:
22mmx100mm pre-treated pine floor boards stained with Woodoc 25
Polyurethane Floor Sealer with Oak stain on 50x228 floor joist @ max 600mm

1800
spacing on bearers as per SANS 10400 - part J and according to engg.
2M BUILDING LINE

2000
design

3212
100mm isotherm / rockwool insulation or simlar approved beneath floor
boards.
1200MM HIGH METAL BEDROOM 2
MESH FENCING PLUMBING:
ERF XXXX 13 m² BATHROOM: Fixtures as per drawing. Main house: geyser to be Kwikot
Site / Roof plan L
Kwiksol 150L Solar Geyser, 2nd Dwelling: Kwikot 100L Solar Geyser or
similar approved. Geysers mounted on roof by specialist according to
2 EUROLUX WATERTIGHT
manufacturers spec.
KITCHEN: Gas stove to be supplied and fitted by contractor. Allowance for
1 : 200 GLASS LIGHT FITTING FIXED

16748
Metal siding as per notes 9kg gas bottle below counter according to SABS standard by accredited
TO WALL AT 2100 AFFL installer.
Clear Polycarbonate Sheeting Foul water and grey water to gulley to council connection.
B All plumbing work to be carried out in accordance to SANS 10400.
450 4 ELECTRICAL:
All plug points as per plan. Plug points to be standard double plugs. DB board
as indicated on plan or alternative position by electrian TBC by client.
STUDY

1667
1040
DN L Lighting switches and fixtures as per plan. Exterior flood lighting as per plan.
5 m² All electrical work to be carried out by certified electrician.
WINDOWS & DOORS:
As per plan and elevation. All to be Swartland Kayo Timber doors and
windows except where indicated. All to be swartland light oak stained.
FOUNDATIONS:
Main dwelling and Cottage to be built on stilts. Typical footings for all stilts:
00 Ground Storey Poles to be placed on 600x600x125 precast concrete pad at least 1200mm
0 B below ground level. Base of hole to be well compacted before concrete pad
placed and pole positioned. Hole to be backfilled in 150mm well compacted
thick layers of suitable filling material. Foundations and poles as per engineer
STANDARD SWITCHES drawings.
{3D}

EXST. DRIVEWAY
RAINWATER GOODS:

3 8 Half-round uPVC Marley gutter or equal approved with standard 75mm


downpipes as indicated on plan. All new downpipes to discharge into

1800
A101 municipal storm water drain.
North West EGL All drainage pipes passing below foundations to be encased in 100mm
TIMBER SCREEN: 38X38
BATTANS ON 118X38 UPRIGHTS 4 STANDARD DOUBLE PLUG concrete all round.
CARPORT:
1 : 100 DISTRIBUTION BOARD db Dimensions as indicated on plan. Placed on existing garage concrete slab.
Uprights to be 100mm H2 treated timber poles or similar approved. Design to
later detail. Roof covering to be waterproof, UV stable, 90% shade cloth or
similar approved. Carport to have no siding.

FRIDGE
polycarbonate sheeting SUNDRIES:

650
B Fans: Main House - added to all bedrooms and 2 x in lounge/kitchen. 2nd
114X38 TIMBER RAIL Kitchen / Dinning / TV DECK Dwelling - 1x in loung, 1x over bed. Type EUROLUX Colonial Ceiling Fan,
2800

Dual Mount Motor (4 Steel Blades Colour - Dark Wood, 1200mm Diameter)

6502
80X80 TIMBER POST OR SIMILAR 34 m² 15 m²
2405

600
Driveway 4 Fencing: As indicated on plan. Uprights to be H3 treated gum poles with
300
TIMBER SLATES / PLANKS PG BISON FORMICA LIFESEAL Chicken Netting Wire 25x0.90x1200mm or similar approved.
940 A102 Water Storage: 5500L Jojo Vertical Storage tank - colour to be Winter Grass
157

COUNTERTOP. COLOUR/STYLE
00 Ground Storey "BROOKYLN LOFT" OR SIMILAR or Storm Sky
Driveway APPROVED Site to be cleared of all alien vegetation
0
Burglar bars to both dwellings: Clear polycarbonate burglar bars added to all
940 window openings.

2600

1760
00 Ground Storey Alarm System to both dwellings: Supply and install Mix Box WIFI Home
FRANKE NOUVEAU KITCHEN SINK WITH Security System Alarm Wireless IP GSM System Kit from Takealot or similar
EQ EQ
0 WASTE FITTINGS NVN621 - 1160 X 460MM approved
WITH CHROMECATER SINK MIXER`FLEX & Solar Power - Main House: Supply and install 1 xSunsynk 5kW 1P Hybrid PV
as per engg. STAY`BRUSHED S/STEEL/BLUE HOSE OR 48V Inverter, 1 x Hubble AM-3 - 51v Lithium-Ion Battery 2.75kWh, 5 x JA or
SIMILAR APPROVED Canadian 550w Monocrystal Panels. 2nd Dwelling: Supply and install 1 x
1780
Growatt SPF 3000TL 3KW 24v Inverter, 1 x Plyontech 2.4kw US2000C
DOUBLE PLUG @ 1200 AFFL Lithium Ion Battery, 2 x Jinko 460w Monocrystal Panels. Inverters to be
connected to DB board by certified electrician to dedicated circuits. Circuits
B

STOVE
Cottage North West

GAS
TBC by client. Panels to be mounted on roof at correct angles according to
GAS BOTTLE TO STOVE
Section 1 11 STORED BELOW HOUSE
DEFY 600 MM 4-BURNER TURBO GAS STOVE
manuals specification. Panels to be connected in series. All fittings and
cables to be supplied and installed by certified electrician.

8 1 : 100 OR SIMILAR APPROVED


2440 9
2ND DWELLING:
Foundations, stilts, walls, floors, roof, doors/windows, balustrading, deck,
plumbing, bathroom and kitchen joinery, electrical and light fixtures all to be
1 : 100 DEFY 2 BURNER GAS HOB STAINLESS STEEL OR
SIMILAR APPRVD. GAS BOTTLE TO STOVE
3
A101 the same as main house. Solar sytem - see Sundries:
2259
Swartland Patio Door in Frame Swartland Patio Door in Frame STORED BELOW HOUSE A102
SD7/1612/2.4 SD7/1612/2.4 PG BISON FORMICA LIFESEAL COUNTERTOP. 11
COLOUR/STYLE "BROOKYLN LOFT" OR SIMILAR A101
1879
APPROVED Revisions
1800 1800 830
JOINERY CONSTRUCTION TO BE SAME AS
MAIN HOUSE AND SECTION 3 ON DRAWING 1 2021/08/19 Extras Added: Carport, Fencing, Jojo Tank, Burglar
bars, Solar Geyser, Ceiling Fans, Wall sisilation,
1200

A102
1500

1500

1500
Mirco alarm system, Solar system
1800 FRANKE NOUVEAU NVN611 SINK SEB B

2400
Driveway 2 2021/09/02 Additions: 2nd dwelling (cottage), gas stove to main
800X460X149MM WITH BSW SATIN STAINLESS dwelling, exterior flood lighting on site plan, corrugate
1200

STEEL WITH CHROMECATER SINK MIXER`FLEX &


1100

940 metal siding thickness stipulated, concrete footings


900

900
00 Ground Storey STAY`BRUSHED S/STEEL/BLUE HOSE OR SIMILAR changed, fence along street moved
APPROVED
0 DISTRIBUTION BOARD DECK
B L L 9 m²

KITCHEN / LOUNGE / BEDROOM


25 m²
Project:
640

Main Dwelling South East


B
5 TEMPLEMAN

5357
9 HWB

1 : 100 North East


6 BATHROOM
Client: Mr Blair - proposed plans
1 : 100 4 m² 450MM HIGH BUILT IN
BENCH SEAT
ERF 5220
Corrugated
WC
5 Templeman Drive

1800
stilt / column ground to rafter bearer to eng spec. polycarbonate sheeting Knysna Heights
Corrugated polycarbonate sheeting Timber beam to eng. spec
Corrugated metal sheeting

SH Signatures
Owner/s: Architect:
B
900

900

610
Driveway
2100

610
2045 Drawing Title:
1100

940
00 Ground Storey 5671 Plans, Elevations
0
Drawing Status:
Proposed Plans
2739

3400

Typical method for founding stilts. concrt. to engg spec


See construction notes. To engg. detail Project number Date
min 1200

4500

Suitable compacted substrate stilts to engg spec 21-8 2021/04/26


Drawn by Checked by
150

Concrete base min 125mm


600 2689 ANB Checker

Cottage South East EGL


A101 Rev: 2
South West 00 Ground Storey
5 7 1 Page Size: A1 Scale As indicated
1 : 100
1 : 100 1 : 50