Drawing No:

Equipment:
Panel Ref: -
Page:
Date:
SITE TEST REPORT FOR TRANSFORMER

Name Plate Details:

Make: ABB S.No:

KVA Rating

Type of cooling
HV Voltage in KV
LV Voltage in V
HV current in Amps

LV Current In
Amps
% Impedance

a) Vector Group:
b) OLTC type:

1. Insulation resistance test:

Reference DC applied voltage Measured Values


IR VALUE PI = R 600
@60 SEC /R 60
HV - Earth 5 kV
LV - Earth 500 V
HV - LV 5 kV

2. Magnetizing Current Test:


a) HV Side

Tap position Voltage applied in H.V (volts) HV Current in Ma

A-B B-C A-C A B C

[Type here]
TESTED BY WITNESSED BY CLIENT WITNESSED/APPROVED BY OWNER

NAME……………............. NAME………………………………… NAME……………………………….


SIGNATURE…………….. SIGNATURE…………………………. SIGNATURE………………………..

DATE…………………….. DATE…………………………………. DATE………………………………..


Drawing No:
Equipment:
Panel Ref: -
Page:
Date:
SITE TEST REPORT FOR TRANSFORMER

3. Magnetic balance test: At Nominal tap(3)

(a) HV Side

Voltage applied in volts Voltage measured in volts


A-B B-C A-C
A-B
B-C
A-C

(b) LV Side

Voltage measured in volts


a-b b-c a-c a-n b-n c-n

4. Vector group Test: At Nominal tap(2N)

[Type here]
TESTED BY WITNESSED BY CLIENT WITNESSED/APPROVED BY OWNER

NAME……………............. NAME………………………………… NAME……………………………….


SIGNATURE…………….. SIGNATURE…………………………. SIGNATURE………………………..

DATE…………………….. DATE…………………………………. DATE………………………………..


Drawing No:
Equipment:
Panel Ref: -
Page:
Date:
SITE TEST REPORT FOR TRANSFORMER

CONDITION:

Applied 415V at HV, A & a shorted.

1) A-a = 0

2) A-B = A-n + B-n

3) A-c=A-b

4) C-b>C-c

5. Winding resistance measurement:

(a) HV winding

Tap No H.V Winding


A-B in Ω B-C in Ω A-C in Ω
1
2
3
4
5

[Type here]
TESTED BY WITNESSED BY CLIENT WITNESSED/APPROVED BY OWNER

NAME……………............. NAME………………………………… NAME……………………………….


SIGNATURE…………….. SIGNATURE…………………………. SIGNATURE………………………..

DATE…………………….. DATE…………………………………. DATE………………………………..


Drawing No:
Equipment:
Panel Ref: -
Page:
Date:
SITE TEST REPORT FOR TRANSFORMER

(a) L.V Winding

L.V Winding
a-n in mΩ b-n in mΩ c-n in mΩ

6. Ratio Test:

Condition: 3 Phase 415 V Applied at H.V and L.V kept 0pen

TAP NO Voltage applied in H.V( volts) Voltage measured in L.V (volts)


A-B B-C A-C a-b b-c a-c a-n b-n c-n
1
2
3
4
5

7. Short circuit test:


Condition: 3 Phase 415 V Applied at H.V and L.V shorted.
(a) Between HV & LV

Tap Voltage applied in H.V HV Current in Amps LV Current in Amps


No (volts)
A-B B-C A-C A B C a b C

[Type here]
TESTED BY WITNESSED BY CLIENT WITNESSED/APPROVED BY OWNER

NAME……………............. NAME………………………………… NAME……………………………….


SIGNATURE…………….. SIGNATURE…………………………. SIGNATURE………………………..

DATE…………………….. DATE…………………………………. DATE………………………………..