C1. Colt intrand pereti zidarie, fara stalpisori b.a. - fara termoizolatie la exterior
Zidarie BCA grosime 25 cm

λ BCA λt pag. Rtherm Lther ΔΘ Hflow Hflux B R Metoda1 Ψ=ltherm/Rtherm-B/R [w/mK] Metoda2 Ψ=φ/ΔΘ-B/R [w/mK]
[W/mK] [W/mK] [mpK/W] [mm] K [W] [W/m2] [mm] [m2k/w] [W/mk] [W/mk]
BCA 25 0.25 - 248 Ψ1 Ψ1= 2.400 / 2.8081 - 1.200 / 1.2203 = -0.129 Ψ1= 29.913 / - 1.200 / 1.220 = -0.129
2.808 2,400 35 29.913 12.464 1,200 1.220 35
BCA 25 0.25 - 248 Ψ2 Ψ2= 1.200 / 1.1811 - 1.500 / 1.2203 = -0.213 Ψ2= 35.560 / - 1.500 / 1.220 = -0.213
1.181 1,200 35 35.560 29.633 1,500 1.220 35
BCA 25 0.35 - 248 Ψ1 Ψ1= 2.400 / 2.1447 - 1.200 / 0.9345 = -0.165 Ψ1= 39.167 / - 1.200 / 0.935 = -0.165
2.145 2,400 35 39.167 16.320 1,200 0.935 35
BCA 25 0.35 - 248 Ψ2 Ψ2= 1.200 / 0.9071 - 1.500 / 0.9345 = -0.282 Ψ2= 46.300 / - 1.500 / 0.935 = -0.282
0.907 1,200 35 46.300 38.583 1,500 0.935 35

Calculul rezistentei unidirectionale cu λ = 0.25 [W/mK]:


. . .
R= + + + + = 0.125 + 0.0215 + 1 + 0.0322 + 0.0416 = 𝟏. 𝟐𝟐𝟎𝟑 [m2k/w]
. . .
Calculul rezistentei unidirectionale cu λ = 0.35 [W/mK]:
. . .
R= + + + + = 0.125 + 0.0215 + 1 + 0.0322 + 0.0416 = 𝟎. 𝟗𝟑𝟒𝟓 [m2k/w]
. . .

Fig.1 Fig.2 Fig.3 Fig.4

Fig. 1-2: Zidarie BCA grosime 25 cm cu λ = 0.25 [W/mK]


Fig. 3-4: Zidarie BCA grosime 25 cm cu λ = 0.35 [W/mK]

Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ


Echipa 4: Grupa: C_3111
Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ
Echipa 4: Grupa: C_3111
D1. Soclu, subsol neincalzit, cu termoizolatie la pardoseala si soclu 10 cm
Zidarie BCA grosime 35 cm, planseu b.a. 15 cm

λ BCA λt pag. Rtherm Lther ΔΘ Hflow Hflux B R Metoda1 Ψ=ltherm/Rtherm-B/R [w/mK] Metoda2 Ψ=φ/ΔΘ-B/R [w/mK]
[W/mK] [W/mK] [mpK/W] [mm] K [W] [W/m2] [mm] [m2k/w] [W/mk] [W/mk]
BCA 35 0.25 - 315 Ψ1 Ψ1= 1.200 / 1.5181 - 1.200 / 1.6203 = 0.050 Ψ1= 27.666 / - 1.200 / 1.620 = 0.050
1.518 1,200 35 27.666 23.055 1,200 1.620 35
BCA 35 0.25 - 315 Ψ2 Ψ2= 1.200 / 4.0342 - 1.000 / 2.6234 = -0.084 Ψ2= 10.411 / - 1.000 / 2.623 = -0.084
4.034 1,200 35 10.411 8.676 1,000 2.623 35
BCA 35 0.35 - 315 Ψ1 Ψ1= 1.200 / 1.1497 - 1.200 / 1.2204 = 0.060 Ψ1= 36.531 / - 1.200 / 1.220 = 0.060
1.150 1,200 35 36.531 30.443 1,200 1.220 35
BCA 35 0.35 - 315 Ψ2 Ψ2= 1.200 / 3.8272 - 1.000 / 2.6234 = -0.068 Ψ2= 10.974 / - 1.000 / 2.623 = -0.068
3.827 1,200 35 10.974 9.145 1,000 2.623 35

Calculul rezistentei unidirectionale pentru BCA cu λ = 0.25 [W/mK]:


. . .
R= + + + + = 0.125 + 0.0322 + 1.4 + 0.0215 + 0.0416 = 𝟏. 𝟔𝟐𝟎𝟑 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru BCA cu λ = 0.35 [W/mK]:


. . .
R= + + + + = 0.125 + 0.0322 + 1.4 + 0.0215 + 0.0416 = 𝟏. 𝟐𝟐𝟎𝟒 [m2k/w]
. . .
Calculul rezistentei unidirectionale pentru perete subsol:
. . . .
R= + + + + + = 0.083 + 0.0322 + 2.2727 + 0.1724 + 0.0215 + 0.0416 = 𝟐. 𝟔𝟐𝟑𝟒 [m2k/w]
. . . .

Fig.1 Fig.2 Fig.3 Fig.4

Fig. 1-2: Zidarie BCA grosime 35 cm cu λ = 0.25 [W/mK]


Fig. 3-4: Zidarie BCA grosime 35 cm cu λ = 0.35 [W/mK]

Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ


Echipa 4: Grupa: C_3111
Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ
Echipa 4: Grupa: C_3111
E1. Intersectie perete exterior cu planseu curent b.a. - cu termoizolatie la exterior
Pereti structurali (centura), zidarie BCA grosime 25 cm, planseu b.a. 15 cm

λ BCA λt pag. Rtherm Lther ΔΘ Hflow Hflux B R Metoda1 Ψ=ltherm/Rtherm-B/R [w/mK] Metoda2 Ψ=φ/ΔΘ-B/R [w/mK]
[W/mK] [W/mK] [mpK/W] [mm] K [W] [W/m2] [mm] [m2k/w] [W/mk] [W/mk]
BCA 25 + POL 5 0.25 0.044 369 Ψ1 Ψ1= 1.200 / 1.9588 - 1.295 / 2.3244 = 0.055 Ψ1= 21.441 / - 1.295 / 2.324 = 0.055
1.959 1,200 35 21.441 17.868 1,295 2.324 35
BCA 25 + POL 5 0.25 0.044 369 Ψ2 Ψ2= 1.200 / 2.0326 - 1.320 / 2.3244 = 0.022 Ψ2= 20.664 / - 1.320 / 2.324 = 0.023
2.033 1,200 35 20.664 17.220 1,320 2.324 35
BCA 25 + POL 5 0.35 0.044 369 Ψ1 Ψ1= 1.200 / 1.7651 - 1.295 / 2.0386 = 0.045 Ψ1= 23.795 / - 1.295 / 2.039 = 0.045
1.765 1,200 35 23.795 19.829 1,295 2.039 35
BCA 25 + POL 5 0.35 0.044 369 Ψ2 Ψ2= 1.200 / 1.8146 - 1.320 / 2.0386 = 0.014 Ψ2= 23.146 / - 1.320 / 2.039 = 0.014
1.815 1,200 35 23.146 19.289 1,320 2.039 35
BCA 25 + VAM 5 0.25 0.048 369 Ψ1 Ψ1= 1.200 / 1.871 - 1.295 / 2.2297 = 0.061 Ψ1= 22.448 / - 1.295 / 2.230 = 0.061
1.871 1,200 35 22.448 17.868 1,295 2.230 35
BCA 25 + VAM 5 0.25 0.048 369 Ψ2 Ψ2= 1.200 / 1.9434 - 1.320 / 2.2297 = 0.025 Ψ2= 21.612 / - 1.320 / 2.230 = 0.025
1.943 1,200 35 21.612 17.220 1,320 2.230 35
BCA 25 + VAM 5 0.35 0.048 369 Ψ1 Ψ1= 1.200 / 1.6782 - 1.295 / 1.9439 = 0.049 Ψ1= 25.026 / - 1.295 / 1.944 = 0.049
1.678 1,200 35 25.026 19.829 1,295 1.944 35
BCA 25 + VAM 5 0.35 0.048 369 Ψ2 Ψ2= 1.200 / 1.7263 - 1.320 / 1.9439 = 0.016 Ψ2= 24.330 / - 1.320 / 1.944 = 0.016
1.726 1,200 35 24.330 19.289 1,320 1.944 35

Calculul rezistentei unidirectionale pentru BCA cu λ = 0.25 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]:
. . .
R= + + + + = 0.125 + 1.1363 + 1 + 0.0215 + 0.0416 = 𝟐, 𝟑𝟐𝟒𝟒 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru BCA cu λ = 0.35 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]:
. . .
R= + + + + = 0.125 + 1.1363 + 0.7142 + 0.0215 + 0.0416 = 𝟐, 𝟎𝟑𝟖𝟔 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru BCA cu λ = 0.25 [W/mK] si vata minerala cu λ = 0.048 [W/mK]:
. . .
R= + + + + = 0.125 + 1.0416 + 1 + 0.0215 + 0.0416 = 𝟐, 𝟐𝟐𝟗𝟕 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru BCA cu λ = 0.35 [W/mK] vata minerala cu λ = 0.048 [W/mK]:
. . .
R= + + + + = 0.125 + 1.1363 + 0.7142 + 0.0215 + 0.0416 = 𝟏. 𝟗𝟒𝟑𝟗 [m2k/w]
. . .

Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ


Echipa 4: Grupa: C_3111
Fig.1 Fig.2 Fig.3 Fig.4

Fig.5 Fig.6 Fig.7 Fig.8

Fig. 1-2: Zidarie BCA grosime 35 cm cu λ = 0.25 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]
Fig. 3-4: Zidarie BCA grosime 35 cm cu λ = 0.35 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]
Fig. 5-6: Zidarie BCA grosime 35 cm cu λ = 0.25 [W/mK] si vata minerala cu λ = 0.048 [W/mK]
Fig. 7-8: Zidarie BCA grosime 35 cm cu λ = 0.35 [W/mK] si vata minerala cu λ = 0.048 [W/mK]

Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ


Echipa 4: Grupa: C_3111
Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ
Echipa 4: Grupa: C_3111
E1. Intersectie perete exterior cu planseu terasa (atic, cornisa) cu termoizolatie la exterior
Pereti structurali (centura), zidarie caramida grosime 30 cm, planseu b.a. 15 cm - Termoizolatie terasa 20 cm

λ CAR λt pag. Rtherm Lther ΔΘ Hflow Hflux B R Metoda1 Ψ=ltherm/Rtherm-B/R [w/mK] Metoda2 Ψ=φ/ΔΘ-B/R [w/mK]
[W/mK] [W/mK] [mpK/W] [mm] K [W] [W/m2] [mm] [m2k/w] [W/mk] [W/mk]
CAR 30+POL20 0.5 0.044 572 Ψ1 Ψ1= 1.200 / 3.0209 - 1.200 / 5.3135 = 0.171 Ψ1= 13.903 / - 1.200 / 5.314 = 0.171
3.021 1,200 35 13.903 11.586 1,200 5.314 35
CAR 30+POL20 0.5 0.044 572 Ψ2 Ψ2= 1.200 / 2.4345 - 1.200 / 4.9702 = 0.251 Ψ2= 17.252 / - 1.200 / 4.970 = 0.251
2.435 1,200 35 17.252 14.377 1,200 4.970 35
CAR 30+POL20 0.6 0.044 572 Ψ1 Ψ1= 1.200 / 2.9068 - 1.200 / 5.2168 = 0.183 Ψ1= 14.449 / - 1.200 / 5.217 = 0.183
2.907 1,200 35 14.449 12.041 1,200 5.217 35
CAR 30+POL20 0.6 0.044 572 Ψ2 Ψ2= 1.200 / 2.4681 - 1.200 / 4.9702 = 0.245 Ψ2= 17.017 / - 1.200 / 4.970 = 0.245
2.468 1,200 35 17.017 14.181 1,200 4.970 35
CAR 30+VAM20 0.5 0.048 572 Ψ1 Ψ1= 1.200 / 2.9072 - 1.200 / 4.9347 = 0.170 Ψ1= 14.447 / - 1.200 / 4.935 = 0.170
2.907 1,200 35 14.447 12.039 1,200 4.935 35
CAR 30+VAM20 0.5 0.048 572 Ψ2 Ψ2= 1.200 / 2.4213 - 1.200 / 4.9702 = 0.254 Ψ2= 17.346 / - 1.200 / 4.970 = 0.254
2.421 1,200 35 17.346 14.455 1,200 4.970 35
CAR 30+VAM20 0.6 0.048 572 Ψ1 Ψ1= 1.200 / 2.7972 - 1.200 / 4.838 = 0.181 Ψ1= 15.015 / - 1.200 / 4.838 = 0.181
2.797 1,200 35 15.015 12.513 1,200 4.838 35
CAR 30+VAM20 0.6 0.048 572 Ψ2 Ψ2= 1.200 / 2.4546 - 1.200 / 4.9702 = 0.247 Ψ2= 17.111 / - 1.200 / 4.970 = 0.247
2.455 1,200 35 17.111 14.259 1,200 4.970 35

Calculul rezistentei unidirectionale pentru zidarie de caramida cu λ = 0.5 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]:
. . .
R= + + + + = 0.125 + 4.5454 + 0.58 + 0.0215 + 0.0416 = 𝟓. 𝟑𝟏𝟑𝟓 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru zidarie de caramida cu λ = 0.6 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]:
. . .
R= + + + + = 0.125 + 4.5454 + 0.4833 + 0.0215 + 0.0416 = 𝟓. 𝟐𝟏𝟔𝟖 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru zidarie de caramida cu λ = 0.5 [W/mK] si vata minerala cu λ = 0.048 [W/mK]:
. . .
R= + + + + = 0.125 + 4.1666 + 0.58 + 0.0215 + 0.0416 = 𝟒. 𝟗𝟑𝟒𝟕 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru zidarie de caramida cu λ = 0.6 [W/mK] si vata minerala cu λ = 0.048 [W/mK]:
. . .
R= + + + + = 0.125 + 4.1666 + 0.4833 + 0.0215 + 0.0416 = 𝟒. 𝟖𝟑𝟖 [m2k/w]
. . .

Calculul rezistentei unidirectionale pentru placa terasa b.a. cu λ = 1.74 [W/mK] si polistiren celular cu λ = 0.048 [W/mK]:
. . . . .
R2 = + + + + + + = 0.125 + 0.043 + 4.5454 + 0.1075 + 0.0862 + 0.0215 + 0.0416 = 𝟒. 𝟗𝟕𝟎𝟐 [m2k/w]
. . . . .

Diana MATEI - Tibor Albert ASZALOS - Simi Cristian TOMOIOAGĂ


Echipa 4: Grupa: C_3111
Fig.1 Fig.2 Fig.3 Fig.4

Fig.5 Fig.6 Fig.7 Fig.8

Fig. 1-2: Zidarie de caramida cu λ = 0.5 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]
Fig. 3-4: Zidarie de caramida cu λ = 0.6 [W/mK] si polistiren celular cu λ = 0.044 [W/mK]
Fig. 5-6: Zidarie de caramida cu λ = 0.5 [W/mK] si vata minerala cu λ = 0.048 [W/mK]
Fig. 7-8: Zidarie de caramida cu λ = 0.6 [W/mK] si vata minerala cu λ = 0.048 [W/mK]