P/N:110401108121X Jun 1,2019 65x20mm.

charge on i
4) Max Display Value: 4000; Overrange display "OL“, all
capacitors o
refresh 4 times/second.
must be n
5) Measuring range: Auto Range.
released. .
6) Bacl‹light Manual, automatic shut down when 5 mins 8) Data hold indicator: *. When
inactive, long press HOLD/Light to turn on/off the measuring e Insert the
9) Low battery indicator. 4) Diode Measurement (see picture 3) transistor
backlight. low e Switch the dial to diode position.
10) Battery: AA battery (zinc manganese) 1.SV x 2 (PNP or
7) Polarity: Negative input display "—" symbol. resistance e Insert the red
11) Operating temperature: 0”C-40”C (32°F-104°F) Storage temperature: -10”C-50”C (14°F - NPN type)
122°F) (V1), the test lead to poles (B, E,
Relative humidity: 0”C-below 30”C 175%; 30”C-40”C T50%. test leads the "VCtmA" C) into the
may jack, black to correspondi
12) Electromagnetic compatibility:
I. Introduction RF11V/m, overall accuracy=specified accuracy+5% of range. RF> 1V/m, no specified calculation. produce the
jack,
"COM"
then
ng socket,
o.1n-o.2n the hFE
The new generation of XCRK 90 series digital multimeter connect the
has an innovative industrial design which ensures that the 7. External Structure and Test Leads Storage (picture 1) measurem
two test lead
value will be
displayed
product can withstand a drop of 2 meters height. Large ent error.
2 tips to both on the
LCD screen To obtain ends of the
4 accurate screen.
provides a clear display and its 4 times/second sampling 1 PN junction.
rate provides users with more accurate readings. XCRK 3 LCD display Functional buttons measurem e 'OL" symbol
6 6) C
series is designed to work safely in CAT II 1000V/CAT III 5 Transistor input terminal Functional switch ent, short appears ap
600V environment. This series is suitable for 7 VCtmA input terminal COM input terminal the test when the ac
civil/commercial use such as HVAC technicians and leads to diode iS
10A current input terminal Test leads ita
obtain the open or
electricians. 8. Functional Buttons resistance polarity is
nc
e
e SELECT: Press to cycle through the AC/DC mV range, AC/DC current range, diode/continuity, and reversed.
2. Features temperature function (Only for mY - i- ->r. -IF °C°F).
value (V2).
For silicon M
ResuIt=V1 ea
eErgonomic design, comfortable and e HOLD/@- : Press the button to perform data hold/cancel data PN junction,
-V2. normal su
solid. eCan withstand a drop of 2 hold. Press this button 2s to turn on/off the backlight. *. When re
value:
meters height. e4 times/second measurin m
500-800mV (0.5-0.8V).
sampling rate. 9. Measurement Instructions g high & Notes: en
eFull protection which can withstand overvoltage shock up to Please check the attached AA 1.5Vx2 batteries first. To avoid false reading, replace the battery if the resistanc t
*. To avoid instrument damage and injury to users, before
1kV, and designed with overvoltage and overcurrent battery low power symbol ' ”appears. Also pay special attention to the warning sign '@' besides the e, it may (s
7 -"
alarm. eFast capacitance measurement, response time test lead plug, it indicates that the tested voltage or current must not exceed the values listed on take a circuit must be turned off and the residual charge on all ee
3s when capacitance T1 mF, response time is about 6s the device. few capacitors must be released. pi
when capacitance T10mF. seconds *. Voltage for testing diode is about 3 V. ct
eLow power consumption, automatic power saving prolongs 1) AC/DC Voltage Measurement (see picture 2) to s tabil ur
battery life up to 400 hours. 5) e
e Switch the dial to AC voltage ize
e Insert the red test lead to the "VCtmA" jack, black to the "COM" jack, then connect the two test lead h 4)
reading,
3. Accessories tips to both ends of the measured voltage (parallel to the load). which is a F e
Open the package box and take out the device. Please E S
n orm ai
@Notes: wit
check whether the following items are deficient or phenome
*. Do not input voltage over 1000Vrms, or it may pose shock hazard. If the measured voltage range is not ch
damaged: non. M
known before the measurement, set the switch to the highest range, and then gradually reduce the th
1) User manual---------------------1 pc *. Do not input over 60V DC or 30V AC. e e
2) Test leads------------------------1 pair measuring range according to the actual reading ( LCD display 0L indicates over-range, need to increase
a di
3) Protective case------------------1 pc the measuring range ). Measurement accuracy might be affected when large circuit impedance is
present. s al
4) Thermocouple-------------------1 pc (only for XCRK-98) to
* Be cautious when measuring high voltage. u
6 Warning: Before using the instrument, please read ca
*. Before using the device, it is suggested to measure a known voltage for verification. r
the ”Safety operation guidelines" carefully. pa
e cit
m an
ce
4. Safety Operation Guidelines e
po
1) Safety Certification n siti
eDesign according to IEC61010-1: 2010, 61010-2- t on
030:2010, ( .
61010-2-033:2012, 61326-1:2013, 61326-2-2:2013. s e Insert the
eComplies with the safety standards of CAT II 1000V/ red test
e lead to the
CAT III 600V and material contamination grade II.
3) Continuity Measurement (see picture 3) e "VL2mA"
2) Safety Instructions and Precautions e Switch the dial to continuity position. jack, black
eDo not use the device if the rear cover is not covered e Insert the p to the
up or it will pose a shock hazard. red test "COM” jack,
i then
eDo not use the device if the device or test leads lead to the
appear damaged or if you suspect that the device is 2) Resistance Measurement (see picture 3) c connect the
"VC!mA"
not operating properly. Pay particular attention to the + Switch the dial to resistance position. t two test lead
jack, black
insulation layer. eKeep the fingers behind the finger + Insert the red test lead to the "VCImA" jack, black to the "COM" jack, then connect the two test lead tips to u tips to both
to the
both ends ends of the measured voltage (parallel to the load). ends of the
guard during operation. 'COM” r measured
eDo not input voltage over 1000V between the instrument jack, then e capacitor.
terminal and ground to prevent electric shocks or 2{'t Notes: connect e When
damages to the instrument. “. To avoid instrument damage and injury to users, belore measuring the resistance online, all power the two there is no
eBe cautious to prevent electric shock if the measured DC supplies in the circuit must be turned off and the residual charge on all capacitors must be test lead 3 input, the
voltage > 60V or AC voltage > 30Vrms. released. tips to ) screen will
eDo not input oyerrange value. “ If the resistance when shorted is more than 0.5Cl, please check if test leads are loosened or damaged. both e also show
eFunctional dial should be switched to proper position. *. If the resistor is open or over the range, the "OL" symbol will be displayed on the screen. measured a fixed
ends. reading
eDo not switch the functional dial during measurement. which is
e When measured resistance > 51CI, circuit is in open status S
eDo not change the internal circuit of the device in order to the
and the buzzer will make no sound. w
avoid the damage to the device and users. inherent
When it capacitanc
eUse the same specification fuse for replacement.
measured e value of
eTo avoid false reading, replace the battery when the c
resistance the device.
battery indicator ' " appears. ñ1OCI, h For small
eDo not use or store the device in high temperature and circuit is in capacitanc
high humidity environment, the performance of the device good t e (<200nF)
may deteriorate after exposure to moisture. conduction measurem
h ent, the
eUse damp cloth to clean the case; do not use detergent status and
the buzzer e measured
containing solvents or abradants.
will be value must
beeping subtract the
d inherent
continuously
5. Electrical Symbols . i capacitance
a value to
> ensure the
@ Low battery & Notes: l measurem
*. To avoid
AC/DC @ t ent
instrument accuracy.
Warning damage o
and injury 6Notes:
Double insulation to users, *. If the tested
before "
High voltage hazard capacitor is
measuring h shorted or
Grounding the F its
continuity capacitance
E
online, all
6. General Specifications power " is over the
specified
1) Max voltage between input teminal and ground: supplies in p
the circuit range, "OL"
1000Vrms. o symbol will
2) 10A terminal: Fuse 10A H 250V fast-acting fuse must be
turned off s be
O5x20mm. displayed
and the it
3) rnA,/uA terminal: Fuse 0.SA H 250V fast-acling fuse residual on the
screen. e Display of electric field intensity.
*. When
measuring 11) Others * Overload protection: 1000Vrms (AC/DC). Guangzhou Xinchuanruike Electronics Co., Ltd.
large *. The device enters normal measurement status in 2 *. K-type (Ni-Cr-Ni-Si) thermocouple is only applicable for Guangzhou salesroom: 391 jiefang middle road, Yuexiu district, Guangzhou.
capacitance, seconds after start-up. temperature less than 250”C/482”F. TEL: 020 - 83328665
it may take a *. The device automatically shuts down if there is no operation
for 30 minutes. You can wake up the device by pressing 7) DC current Measurement
few seconds
to obtain any key, the buzzer will beep once. To disable auto Position Resolution Remark
* When electnc field intensity is 0-100mV, LCD dispbys "EF”. shutdown, switch the dial to OFF position, long press 400.0pA 0.1pA
steady pA
SELETE or HOLD button and turn on the device. 4000pA 1pA
readings. * When electric field intensity is 100-200mV, LCD displays "-". 40.00mA 0.01mA +(1.0%+3)
*. Before * When electñc field intensity is 200-300mV, LCD displays "--". * The buzzer will beep once (about 0.25s) at any valid press
or switch of the dial. mA 400.0mA 0.1mA
measuring * When electric field intensity is 300-400mV, LCD displays "---" 4.000A 0.001A
large *. Input voltage *30V (AC /DC), buzzer will intermittent beep +(1.2%+5)
@ Notes: * When electric field intensity is >400mV, LCD displays '- - -". A 10.00A 0.01A
capacitance and "&" symbol appears.
(>1mF), please * When there is no input, the device may be influenced “. Buzzer beeps continuously 1 minute before automatic & Overload protection: 250Vrms
fully discharge by the strong power frequency. There may be a reading of shutdown. *. pA mA range: FI Fuse 0.5A/’250V @5x20mm.
the capacitors, 50Hz or d0Hz which will not affect the measurement *. Low voltage detection: Battery voltage < 2.4V, ' ’ under-
accuracy. *. 10 A range: F2 Fuse 10A/’250V 65x20mm.
or the LCD will voltage symbol appears, but it can still work normally; after
* Do not input over 60V DC or 30V AC. about 10s, " " flickers for about 40s and displays "Lo.bt” 8) AC current Measurement
display “DIS"
symbol. This is while " " flickers. Then the device will automatically shut Position Resolution Remark
extremely 8) Temperature Measurement tCelsius/Fahrenheit, down in about 2 minutes. 400.0pA 0.1pA
only for  , see picture 6) pA 4000pA 1pA
important for
capacitors with e Switch the dial to temperature position. 10. Technical Specifications 40.00mA 0.01mA +(1.2+5)
e Plug the K-type thermocouple into the device and put the *. Aocuracy: + (a% of reading +b numerical value in least significant mA 400.0mA 0.1mA
high voltage to 4.000A 0.001A
probe on the object. Read the temperature on the screen digit slot), 1 year warranty
avoid shock 10.00A 0.01A +(2.0%+5)
after the value is stable. *. Ambient temperature: 23”Cz5“C (73.4”F-L9”F), A
hazard.
& Notes: relative humidity: s 75%
* The device will display "OL" when it turns on. And it is only Frequency response: 40 1kHz.
}'k Notes: ”. Display: RMS. Accuracy guarantee range: 5 -100% of the
suitable for the K type (Ni-Cr- Ni-Si) thermocouple, which is *. To ensure accuracy, operating temperature should be
a temperature sensor. The measured temperature should range, shoned circuit allows least significant digit < 2.
within 18“C -28”C and fluctuation range should be within ”. Input current > 10.10A, “OL” symbol appears.
be less than 250°C/ 482°F (°F=”C*1.8+32). +1”C. ”. Overload protection: Refer to DC current measurement.
* When the device is moved to another space, it is suggested Temperature Coefficient= 0.1*(specified
to use it after 1.5 hours for accurate reading. accuracy)/°C (<18”C or>28”C). 9) Frequency Measurement
1) DC Voltage Measurement Measunng
Range Resolution Accuracy Description
Range Resolution
 Accuracy
400.0mV 0.1mV -L(0.7%+3)
K 4.000V 0.001V . -t(0.5%+2)
40.00V 0.01V +(0.7%+3)
400.0V 0.1V +(0.7%+3)
1000V 1V z(0.7%+3)
7) Frequency Measurement (see picture 5) A Input impedance:
*. Input impedance: About 10M0, at 400mV range 400.0Hz- 0.1Hz-
e Switch the dial to Hz position. +(0.1%+4)
40.00MHz 10kHz
e Insert the red 9) AC/DC current Measurement (see picture 7) z1000M !. Results might be unstable at mV ran9e when no
test lead to the e Switch the dial to AC/DC current position. road is connected. The value becomes stable once the
"VClmA" jack, e Insert the red test lead to the ’VClmA“ jack or the "10A" jack, load is connected (Least significant digit ñ +3).
black to the black to the ”COM" jack, then connect the test leads with the *. Max input voltage: +1000V, when the voltage z1010V,
"COM" jack, circuit in series.
"OL" symbol appears.
* Overload protection: 1000Vrms (AC/DC).
then connect e Prass SELECT to switch beMeen ACA and DCA.
2) AC Voltage Measurement
the two test lead
@Notes: Range Resolution Accuracy Overload protection: 1000Vrms (AC/DC).
tips to both 400.0mV 0.1mV z(1. 0% -1-3)
* Before measuring, switch off the power supply of the circuit,
ends of the
measured
and carefully check the input terminals and the dial position. 4.000V 0.001V +(0. 7"A -1-3) 11. Maintenance
40.00V 0.01V +(1. 0Po -I-3)
* If the range of the measured current is unknown, select the 4'L Warning: Before opening the rear cover, switch off the
signal source. 400.0V 0.IV z(1. 0% -1-3)
maximum range and then accordingly reduce. power supply (remove test leads from the input terminal
1000V 1V -E(1. 0% -1-3)
* If the 'VCImA", "10A" input is overloaded, the internal fuses and the circuit).
will break and must be replaced. * Input impedance: about 1oMn, at 400mV range z
1) General Maintenance
a.VC!mA teminal fuse specification: Fuse 0.SA/250V @5x20mm. 1000MCi.
* Frequency response: 40Hz -1kHz, display sine wave true * Clean the case with a damp cloth and mild detergent. Do
b.10A teminal fuse specification: Fuse 10A/250V O5x20mm.
* To avoid instrument damage and injury to users, do not RMS (average response). not use abrasives or solvents.
connect the test leads in parallel to any voltage circuit during Max input voltage: +1OOOV, when the voltage 2• 1010V, * If there is any malfunction, stop using the device and send
"OL" symbol appears.
the current test. it to maintenance.
* Overload protection: 1000Vrms (AC/DC).
* If the tested current is dose to10A, each measurement time Open circuit voltage :3V,
should be less than10 seconds and the next test 3) Resistance Measurement
Range Resolution Accuracy 0.001Vtest current: abouf 1mA Silicon PN junction voltage: 0.5 - 0.8V.
should be after 15 minutes.
400.00 0.1! +(1.0% + 2)
4.000kCl 0.001kCI E(0.8°A + 2) 0§
40.00kCI 0.01kCi fi(0.8% + 2) hFE15 T eas eaent onditiona r 201 A, Vce=3V)
400.0kCi 0.1kC! +(0.8% + 2)
4.000M0 0.001MCI E(1.2% +2) * The maintenance and service must be implemented by
40.00MCI 0.01MCI E(1.5% +5) qualified professionals or designated departments.
* Measurement result = reading of resistor — reading of 2) Replace Battery or Fuse (see picture 9a, picture 9b)
shoned test leads * To avoid false reading, replace the battery when the
* Overload protection: 1000Vrms (AC/DC). battery indicator " " appears.
4) Continuity, Diode and Battery Specification: AA 1.5Vx2
10) NCV Measurement (only for  Transistor P s * Switch the dial to "OFF” position, remove the test leads
Remark
see picture 8) from the input terminal, remove the protective cover also.
Set Value
* Loosen the screw on battery
Open cover (top),
circuit: remove the no
resistance>50Ci, cover
• I)) 0.1Cl
to replace the batterybeep.Well-connected
(Please 10Ci,
identify thecircuit:
positive and
resistance continuous beeps.
@ Overload protection: 1000Vrsm (AC/DC) negative pole).
5) Capacitance Measurement
Position Resolution - •{-
Remark eWhen the fuse is burned out due to wrong measurement of
4.000nF 0.001nF z(4%+10)
40.00nF 0.01nF z(4%+10) voltage or over-current, some functions may not work
400.0nF 0.1nF +(4%+10) properly, and the fuse should be replaced immediately.
4.000pF 0.001pF +(3%+5) * Switch the dial to "OFF" position and remove the test leads
40.00pF 0.01pF z(3%+5) from the input terminal, remove the protective cover also.
400.0pF 0.1pF +(3%+5) * Loosen the both screws on the rear cover, and then
e To sense whether there is AC voltage or electromagnetic 4.000mF 0.001mF +(4%+10)
remove the rear cover to replace the fuse.
field in the space, please switch the dial to the NCV position. 40.00mF 0.01mF z(10%)
* Fuse specification:
e Place the front end of the device near the measured objecL
F1 Fuse 0.5A/250V O5x20mm ceramic tube
"-"symbol indicates the intensity of the electric field. More
F2 Fuse 10A/’250V O5x20mm ceramic tube
"-" (up to 4 segments) and the higher the buzzer frequency,
the higher the electric field intensity.
§} Temperature Measurement (Only for XCRK-98)
Position Resolution Remark
-40-406 +46
440-500°C d•(1.0%+5)
°C -40-1000°C 4500-1000°C 1°C -E(2.0%+5)
40-104°F +5°F
> 104-932°F +(1.5%+5)
°F -40-1832°F >932-1832°F 1°F z(2.5%+5)