Professional Documents
Culture Documents
26 15 00 Opt 10000 001
26 15 00 Opt 10000 001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
1 DEC18
ZONING DATA
___________
PREPARATION
___________
PROVISION
WORK : SKILL
_____ ___
MEN _________
MAN-HOURS
ELAPSED TIME :
PUBLICATION
___________
6E 26-15-00
OPT 10000-001
2-400 PAGE 1
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
2 DEC18
002 ___________
PREPARATION
004 _____________________
BEGINNING OF THE TEST
6E 26-15-00
OPT 10000-001
2-400 PAGE 2
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
3 DEC18
005 _________________
ALARMS ACTIVATION
6E 26-15-00
OPT 10000-001
2-400 PAGE 3
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
4 DEC18
IN SMK POSITION
C. INHIBIT ALARMS
1. ON PANEL 121VU,
- OPEN, SAFETY AND TAG CIRCUIT BREAKER:
2WA AVIONICS VENT/ELEC SMK DET
6E 26-15-00
OPT 10000-001
2-400 PAGE 4
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
5 DEC18
3. INHIBIT ALARMS
6. ON PANEL 121VU,
- REMOVE SAFETY CLIPS AND TAGS AND
CLOSE CIRCUIT BREAKER:
2WA AVIONIC VENT/ELC SMK DET
NOTE: PRIOR TO PRESS ON PTT PUSHBUTTON
SWITCH, IT MAY BE NECESSARY TO
WAIT FOR ABOUT 10S AFTER HAVING
CLOSED THE CIRCUIT BREAKER
8. INHIBIT ALARMS
6E 26-15-00
OPT 10000-001
2-400 PAGE 5
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
6 DEC18
007 ___________________________________________
OPERATIONAL TEST OF FORWARD SMOKE DETECTION
1. ON PANEL 122VU,
- OPEN, SAFETY AND TAG CIRCUIT BREAKER:
152WA COMPT SMK/FWD COMPT/SMK DET
3. INHIBIT ALARMS
6. ON PANEL 122VU,
- REMOVE SAFETY CLIPS AND TAGS AND
CLOSE CIRCUIT BREAKER:
152WA COMPT SMK/FWD COMPT/SMK DET
6E 26-15-00
OPT 10000-001
2-400 PAGE 6
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
7 DEC18
8. INHIBIT ALARMS
008 ______________________________________________
OPERATIONAL TEST OF LAVATORIES SMOKE DETECTION
1. ON PANEL 122VU
- OPEN, SAFETY AND TAG CIRCUIT BREAKER:
154WA COMPT SMK/LAV SMK DET
6E 26-15-00
OPT 10000-001
2-400 PAGE 7
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
8 DEC18
3. INHIBIT ALARMS
7. ON PANEL 122VU:
- REMOVE SAFETY CLIPS AND TAGS AND
CLOSE CIRCUIT BREAKER:
154WA COMPT SMK/LAV SMK DET
NOTE: PRIOR TO PRESS ON PTT PUSHBUTTON
SWITCH, IT MAY BE NECESSARY TO
WAIT FOR ABOUT 10S AFTER HAVING
CLOSED THE CIRCUIT BREAKER
6E 26-15-00
OPT 10000-001
2-400 PAGE 8
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
9 DEC18
9. INHIBIT ALARMS.
009 _____________________________________________
OPERATIONAL TEST OF AFT COMPT SMOKE DETECTION
1. ON PANEL 122VU
- OPEN, SAFETY AND TAG CIRCUIT BREAKER:
186WA COMPT SMK/AFT COMPT SMK DET
6E 26-15-00
OPT 10000-001
2-400 PAGE 9
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
10 DEC18
3. INHIBIT ALARMS
7. ON PANEL 122VU,
- REMOVE SAFETY CLIPS AND TAGS AND
CLOSE CIRCUIT BREAKER:
186WA COMPT SMK/AFT COMPT SMK DET
6E 26-15-00
OPT 10000-001
2-400 PAGE 10
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
11 DEC18
9. INHIBIT ALARMS.
010 ___________
END OF TEST
1. END OF TEST:
A. ON PANEL 101VU:
- PLACE ROTARY SELECTOR SWITCH
IN NORM FLT POSITION
B. ON PANEL 22VU:
CHECK THAT THE FAULT LEGEND ON THE
EXHAUST MODE PUSHBUTTON SWITCH IS ON
- RESET EXHAUST MODE PUSHBUTTON SWITCH
. LEGEND FAULT GOES OFF
. LEGEND OVBD COMES ON
- PRESS EXHAUST MODE PUSHBUTTON SWITCH
. OVBD LEGEND GOES OFF
. THE ELECTRONIC RACK AIR EXTRACTION
FAN COMES ON
6E 26-15-00
OPT 10000-001
2-400 PAGE 11
DEC 01/18
26-15-00 OPT 10000-001
OPERATIONAL TEST OF
SMOKE DETECTION SYSTEM
12 DEC18
***** E N D O F T E X T *****
6E 26-15-00
OPT 10000-001
2-400 PAGE 12
DEC 01/18
26-15-00 OPT 10000-001
13 DEC18
6E SMOKE DETECTION
MAINTENANCE PANELS
26-15-00
OPT 10000-001
2-400 PAGE 13
DEC 01/18
26-15-00 OPT 10000-001
14 DEC18
6E PANEL 34VU
(IF INSTALLED)
26-15-00
OPT 10000-001
2-400 PAGE 15
DEC 01/18