Fig. 1 - Flange with hole with continuous sealing surface with metal to metal contact
thinnest section)
Number of bolts n
8
The calculation pressure P
1 MPa
Thread M8x1.25
Testing group 1
Joint coefficient z
1
ftest = = = 338.1MPa
1.05 1.05
The hydrostatic end force due to pressure on flange face at the calculation pressure:
π π 2 2
2 2
HT = (G − B ) ⋅ P = (112 − 55 ) ⋅ 1 = 7476.2N
4 4
The hydrostatic end force due to pressure on flange face at the test pressure:
π π 2 2
2 2
HT −test = (G − B ) ⋅ Ptest = (112 − 55 ) ⋅ 1.5 = 11214.4N
4 4
Balancing radial moment in flange along line of bolt holes at the calculation pressure:
Balancing radial moment in flange along line of bolt holes at the test pressure:
The minimum flange thickness, measured at the thinnest section at the calculation pressure:
6MR 6 ⋅ 305029
emin = √ = √ = 4.5mm
fd (π ⋅ C − n ⋅ dh ) 199.3 (π ⋅ 165 − 8 ⋅ 9)
e ≥ emin → 10 ≥ 4.5
Does suit.
The minimum flange thickness, measured at the thinnest section at the test pressure:
6MR−test 6 ⋅ 457547.5
emin−test = √ = √ = 4.3mm
ftest (π ⋅ C − n ⋅ dh ) 338.1 (π ⋅ 165 − 8 ⋅ 9)
e ≥ emin−test → 10 ≥ 4.3
Does suit.
The balancing reaction force outside bolt circle in opposition to moments due to loads
inside bolt circle at the calculation pressure:
HR = MR /hR = 305029/22.5 = 13556.8N
The balancing reaction force outside bolt circle in opposition to moments due to loads
inside bolt circle at the test pressure:
The minimum required bolt load for operating condition at the calculation pressure:
The minimum required bolt load for operating condition at the test pressure:
The total cross-sectional area of bolts at the section of least bolt diameter at the calculation
pressure:
Wop 2926.1
2
AB = = = 14.6mm
fB 200
Does suit.
The total cross-sectional area of bolts at the section of least bolt diameter at the test
pressure:
Wop−test 4389.2
2
AB−test = = = 14.6mm
fB ⋅ 1.5 200 ⋅ 1.5
Does suit.