1 2 3 4 5 6 7 8 9 10

CLIENT:

C:\Users\engs\Documents\2117-B01-A_Omar_Bahaa.rvt 3 2 1
EL 128.600
UPPER ROOF
PE
SL1O:4

1 2 3 PROJECT MANAGER

3600
3850
METAL F5 ROOFING LAYERS G1
COPING AE589 AE587
1:19
SLOPE SOLAR CELLS ROOM EPOXY PAINT CONSULTANT:
EL 125.500 RF 1003

ECG
TOPR

500
EL 125.000
ROOF FLOOR PLAN TOC EL 125.000
ENGINEERING CONSULTANTS GROUP S.A.
ROOF FLOOR PLAN TOC www.ecgsa.com
H GLASS TYPE B H

GLASS TYPE B
REMARKS:
o FGL = 100000 (FIXED LEVEL)= 71.2m.

800
4760
3900
GLASS TYPE A o FFL = FINISHED FLOOR LEVEL.
o TOC = TOP OF CONCRETE.

3900

3900
GLASS TYPE A ENVIRONMENTAL DESIGN LAB o FPL = FINISHED PAVEMENT LEVEL.
FI 2023 o FRL = FINISHED ROAD LEVEL.
o TOPR = TOP OF PARAPET.
o FCL = FINISHED CEILING LEVEL ( FROM FFL)

1600
NOTES:
EDU. 7
1. ALL DIMENSIONS ARE IN MILLIMETER AND ALL LEVELS ARE IN
FI 1003
METER UNLESS OTHERWISE NOTEDTHIS.
EL 121.100

400
FIFTH FFL EL 121.100 2. ALL DRAWING SHOULD BE READ IN CONJUNCTION WITH
RELEVANT DRAWINGS OF STRUCTURE,.HVAC, PLUMBING,
FIFTH FFL ELECTRICAL,ETC.

3. ALL TOILETS WALLS SHALL BE CONSIDERED SOLID BLOCKS.


TRANSOM DETAIL A8
CASE 2 AE582 4. FIRE RATED WALLS SPECIFIED ON LIFE SAFETY DRAWINGS.

G 5. FOR STRUCTURE ELEMENTS REF. TO STR. DRAWINGS. G

800
4000

GLASS TYPE A 6. FOR MISSING DIMENSIONS REF. TO ID DRAWINGS.


GLASS TYPE A

4000

4000
GLASS TYPES
SYMBOL DESCRIPTION

2800
INSULATED DOUBLE GLASS

1600
TYPE A
6 mm THICK TINTED HEAT STRENGHTED LOW-E FOR THE OUTER PANEL
6mm THICK CLEAR FULLY TEMPERED SAFETY CLEAR GLASS FOR THE
EDU. 5 INNER PANEL
16mm MINIMUM AIRSPACE FOR INSULATION
FU 1003 SHADING COFFEANCY .073
EL 117.100 U.VALUE 1.6

400
7650
FOURTH FFL GLASS TYPE B TYPE B SINGLE SPANDRAL GLASS
EL 117.100 8 mm THICK TINTED LAMINATED GLASS PANEL
FOURTH FFL
OUTDOOR LOUNGE & CAFETERIA TYPE C CLEAR SINGLE GLASS
12 mm THICK CLEAR FULLY TEMPERED GLASS
TH 2025
STAINLESS STEEL
A7 HANDRAIL
AE584

GENERAL NOTES

800
GLASS TYPE A
4000

• ALL GLAZING CONFIGURATIONS ARE THE MINIMUM AND SHOULD BE


VERIFIED STRUCTURALLY

4000

4000
• HARDWARE FOR ALL ALUMINIUM OPENING SHALL BE ACCORDING TO
MANUFACTURER STANDARD

20000
12580

F F

2800

1600

28900
EDU. 5
TH 1003
EL 113.100
25050

400
THIRD FFL GLASS TYPE B EL 113.100
THIRD FFL

SUSPENDED A1
CEILING TILES AE585

DEAN

800
4000

SECR. GLASS TYPE A


S 2026
S 2028

4000

4000
A1 CEILING
AE585 TILES

2800

1600
GLASS TYPE A
EDU. 8
S 1020
E E
EL 109.100

400
SECOND FFL EL 109.100
GLASS TYPE B SECOND FFL

GLASS TYPE B

800
4000

4000

GLASS TYPE A
G8 TRANSOM EDU. 9

4000

4000
2660

AE582 TO LINTEL FR 2020


2800

ALUMINIUM D1

2800
CANOPY AE589

1600
GLASS TYPE A
EDU. 7
G1 TRANSOM TO FR 1003
AE582 BASE
EL 105.100

400
FIRST FFL EL 105.100
1600

FIRST FFL
D D

G8 TRANSOM TO A1 A1
AE582 LINTEL GLASS TYPE C AE306 AE306
4650

4650

4650

4650

1
GLASS TYPE C

3
3200

5050
REFER TO LANDSCAPE
REFER TO ID

OPEN GALLERY GRANITE BASE F4


GR 2020 AS APPROVED AE583 REFER TO LANDSCAPE
BY SAMPLE
8/2/2016 4:09:29 PM

G1 TRANSOM TO
AE582 BASE ENTRANCE
EL 100.450 GR 1001
GROUND FFL EL99.700
1000
750

EL 100.450
750

TOC EL100.000 GROUND FFL


TOC

750
C C
Sheet size - ISO A0 (841* 1189 mm)

5700

5700
DISTRIBUTOR ROOM
B1 1005
EL 96.500
1ST BASEMENT TOC EL 96.500
1ST BASEMENT TOC
D8 TRENCH
AE587 COVER
EPOXY COATING
ON PAVERS

EL94.750
TOC
0 AUG 2016 TENDER A.SMMF A.AMAA A.MAME A.ASSN
B REV DATE ISSUED FOR DRW CHK TL PM B
100 mm

PROJECT TITLE:

AAST SMART VILLAGE


EL 93.000 CAMPUS
3500

2ND BASEMENT TOC EL 93.000


3500

2ND BASEMENT TOC


ANTI TRAFFIC COATING DISCIPLINE
EPOXY COATING
ON CONC.SLAB
ON PAVERS ANTI TRAFFIC COATING EPOXY COATING ARCHITECTURAL
50 mm

ON CONC.SLAB ON PAVERS
SHEET TYPE
3.1-SECTIONS AND WALL SECTIONS
EL91.250
Scanning scale

TOC
SHEET TITLE
WALL SECTION 1&2

A1 WALL SECTION 2
1 : 50 0 50 100

A6 WALL SECTION 1 SCALE PROJECT NO BUILDING NO SHEET NO REV.


10 mm

0 50 100
1 : 50
1:50 2117 AE304 0 A
A
1 2 3 4 5 6 7 8 9 10 ECG Copyright - Produced Using BIM Technology
THIS DRAWING AND THE DESIGN IT COVERS ARE THE PROPERTY OF THE ENGINEERING CONSULTANTS GROUP .THEY ARE MERELY LOANED ON THE BORROWER'S EXPRESSED AGREEMENT THAT THEY WILL NOT BE REPRODUCED, COPIED, LOANED, EXHIBITED NOR USED EXCEPT FOR LIMITED AND PRIVATE USE PERMITTED BY WRITTEN CONSENT GIVEN BY THE LENDER TO THE BORROWER.