Download as pdf
Download as pdf
You are on page 1of 21
[LIFTING OPERATION PLAN Location: SHELL TABANGAO TERMINAL [area: Gantry (BLG3 Ecension Project) [Permit Number sk Assessment / JHA Number: ing Plan No: Method Statement Number: NA are Diagramy/Sketch/Caleuations of Ling Operation Enclosed? YESINO [Description of Liting Operation: Lifting of 12° Carbon Steel Pipe using 2.9T Boom Truck Lu category: Routne:Simple Lit Non-Routine: [Crane/B2om Truck Capacty: 2.9 Tons Crane/Boom Truck Model: ACN 7860 / URV34.4 Brand: UNIC Weight of Load: Max. of 675 kgs. Crane/Boom Truck Operator: Jun A. Noche Rigger: Fellx D, Cunag [iting Equipment & Accessories o be used (specify type, SWL and color code) 2. 2.97 Boom Truck 2, Slings and Shackles (inspected and with load test certificate) ~ 3. Taglines 4. Softener 5, Out Risger oad [Al Lifang Operations Require the Following to be Considered but This List Is Net Exhaustive. |W.Cutural, communication and language diutes Conficing tasks in area Wieloht, size, shape and center of gravity of load |NEnvronmental conditions inuting weather and permissible iis Avallabity of approved lifting points cn load 1m Uphting inthe pick-up and lay-down areas; [Method of singing/attaching/cetaching the oad Proximity hazards, obstructions, path of oad 1 Overtuming/ioad integrty/nced for tag ines Im Working under suspended loads i Sutabity and conion of iftng equipment tobe wees {Winial and nal ‘oad postions anc how wil get tere Access and emergency escape routes Experience, competence and traning of personnel |W fiumber of personnel require for tase Im Pre-Use Inspection of equipment by operator {Mitiumber and curation of fs) WE Vstoity of te toad Buffer Zone fn Efect ITASK DETATIS (Step by Step) [PREPARATION OF DOCUMENTS ~ Prepare iting operation plan complete with diagram, Boom truck manual and third party certificate, sing and shackle load test, cetiicate of rigger and operstor for approval. = Upon approval of operation plan and other documents attach the following on the permit to work (PTW), Create a Job Hazard Analysis (HA) onthe liting work to he performed for verification, authorization and issuance, [PREPARATION BEFORE UFTING During toolbox meeting, discuss PTW and JMA to all workers involve in the Uf Life Saving Rules and HSSE Golden Rules tobe followed at all ies, Ensure to discuss 10 questions forthe safeift and understood bythe team. ~ Alwerkers involve should know ther rales clearly and the hazards they will be facing, Wear complete PPE atl times + Permit lsuer to conduct gas testing proc to lifting. ‘lear the area orior to lifting. Make sure that the path and location of boom truckand ling area isclear with anv cobstacles, “Barricade the work area and provide signages for warning. tng area should be limited to the iting team only. Ensure all non-essential personne are clear ofthe area, “Assign two spotters asa guide tothe lorry truck passing by near the location and alzo guide the pedestrian nearby walking. Spotters should be wearing reflectorized vest and gloves. IETING OF 12"CARBON STEEL PIPE Mobilize the boom truck first, place out rgger pad and secure its poston Before lifting, make sure that no workers are near load tobe lifted and lifting team members are at their respective assigned location Tomaintain center lad of 12" Carbon Steel pipe during iting, the rigger will place end secure wo {2} sling on designated lfeng point (approximately 3 feet from end of pipe to center) ofthe carbon steel pine with no twist or snags. ‘Shackle willbe anchored on the hook ofthe Boom tuck using 3 meter length sin. Iwo competent members are assigned to noid the ta ines ang prevent the suspended load fom swinging ‘Boom Truck operator to unload the carbon ste! pipe on is designated location with riggers hand signals. Boom Truck Operator to guide the load tothe unloading spot with care and caution — observing Riggers hand signal Make sure to follow the course ofthe rotation as discussed inthe biting diagram. Once carbon steel pipe isin place and clear, the rigger to uncouple the sings and unhook the hook connected on the sing. ‘The tagline holder then released tag line from the carbon steel plpe, Rigger to signal boom truck operator to it ‘empty lifting arm, “Secure the boom truck nit location making sure that lifting arm and outrigger i retracted, Upon completion, update TPE and TOS that operation has been done and ask or inspection Place the iting arm back tothe boom truck and prepare for damobilation, ethod|a] Of Communication to Be Used Fadia Veal Wand Signals steps Taken to Eliminate Danger to Personnel involved and Others [including barriers where appropriate) + Secure PTW prior to lifting activities. ~ Conduct toolbox alk before work begins including discussion of PTW BHA. + Engure to discuss 10.questions for the safe it + Installation of Baricades and signages «Close Supervision from PIC and Safety Officer + Follow Shell 12 Life Saving Rules and Golden Rules « Lifting equipment inspection prior to use (erane sing shackles, tagline, etc.) + Actual test If of 10 mins Job pre-start safety talk with crew Include 10 Questions fora safe it. 1 Is everyone aware of and do they fully understand the lit 2 Has everyone attended the toolbox alk? 3 Has a pre-use inspection of the lifting equipment been carried out and are theliting accessories tagged or marked with the folowing? YES, ease see attached cerca /load estoy rae, Sing bets Wate working toae end Shacke WUnique identified number Valid earticate date and hoisting procedures applicable tothe lift? 4 Are ll safety devices working? 5 Does everyone know the person in charge ofthe HR? 6 kseveryone competent and aware of his/her tasks? YES, Pease see attached Competency Certificate of Heavy Equipment Operator and mlgger - 7 there a currant lift plan and Job Safety Assessment and does everyone understané the job and precautions? 8 Does everyone know the environmental limits e., maximum permissible wind speed) forthe lift? 8 ls the it area controled and is everyone clear ifthe load falls or swings? 410 Are signaling methods and communication agreed and cleat to everyone? Correct positioning of Crew and Equipment Fic Tor purpose PPE Debrief and learning points: STOP Observations if any 1. Bad weather condition (Heavy rain, Strong Wind Velocity Max wind speed not to exceed 20knats) 2. Emergency Situations pwd om Ani emanaee Horio Wagon See a fe Bate: 1o-G- 2ove Reviewed by: J. mewccnm 7b -SmiVeL Signature Date: ReCuumgina — lApproved by: Signature bate sO 9NUT “220 foment ‘Aa NMA TULL SMM ‘Arg sebwa iso oboe #ASIA INO€S LNOAVT ONIN [aero ‘aVO7 40 LHOIaM, “"q¥O1 G3LVa “ST DNV NOOB, \19N371 W008 “snidvel ONDOM. ‘ONILM TWNIS 'SMIGVY ONDOM ‘ONLI TWN REPORT OF EXAMINATION OF ae “a6 CHEC CORPORATION — cawie me Heavr Ecurmenr cenrnearion Report No. CCR-2020-0442 CRANE OR OTHER LIFTING APPLIANCE _ | Page | of 2 EQUIPMENT YARD, STA. RITA, BATANGAS CITY CMI CONTRACTORS, INC, STA. RITA, BATANGAS CITY AUNIC* BOOM TRUCK, mex. cap. 2.9 Tons, max. Boom Length 10 meters Long Model: URV34 4 Serial No.: F101854 LTO. Reg: ACN 7860 Mle Power DIESEL “ate of Censtrtion not available (Manufactured By: UNIC) “DBs shold be bray ven and Ue ‘Ekessner should site water he ha seen i ‘heat previous rept, (0 7Ton eben Sis ica June 10, 2019 (report no. CCR-2019-0704), 0.7 Te Y@) What examiontin snd tests wee applied? ©) Ace limiting o vervinding soteton devices satsactey ? (Are SW. clewty marked? (2) Type of SLL indiestore isitia weed? “CONDITION AS FOUND (clan, ‘undereariage foundation slewing tak: nines, rel dlp, hooks) ‘pes, duns, gear pulls, lle init sche, ips, THOROUGH VISUAL, FUNCTION AND LOAD TEST. SATISFACTORY. SATISFACTORY SATISFACTORY ~~ hal, fins Bek Tas, chicas ‘bakes, travel wheels, tacks, anes, Chass, el tps chains, rope or chin tac nents mitt whecs, avi, apengs,jcks si Refers Wt any seired and ped ‘thin whic they should be excited ‘md any ciher conditions which the ets making the einai thinks fs aesecary to spec For seting safe ‘sing ‘Moximuin SAFE WORKING LOAD subject to epi renewal, ltertion if ‘my 8 speciod in 3 above. (Px ib canes se overeat) ter obserations Gentine overeat) certify that on 5 i ‘Fesult. The lifting appliance anda +e presented for thorough examination on or before 2.9 Tons , roughly examined the lifting appliance described above and that thi ag true report of the CMI CONTRACTORS, INC. Accredited Te: 8263 Constanci a St, Boy. es Engr. & Tera PME, 3771 (0. 4334368 ing Organization - DOLE-BWC Accreditation No. 1440-18022315-0016 Olympia, Makati City, Tel, 899-0067 / 890-0466, Fax a90.7 20% | } REPORT OF EXAMINATION OF CRANE OR OTHER LIFTING appLiance | Page 2 of 2 eee ee ee piensa aK CHEC conconsnoy crite woHeAW”Eaurwen Centmcanon | Report No, CCR-2020.0442 LOAD TESTING / OPERATIONAL TEST REPORT | *UNIC" BOOM TRUCK, max. cap. 2.9 Tons, max Boom Length 10 M. Long, } EQUIPMENT Model: URV34 4 Serial No.; F101854 L.T.O. Reg: ACN 7860 Wire Rope Hoist Line: main 7mm dia, 4-part lines, Make Fuso Engine #6M61-011581, chassis #°K71HH-750143 }, BTOss wt. 7,500 kg. AS PER LOAD CHART. ACTUAL TEST Boom Length 5.3 meters 5.3 meters . i Work Angle (Radius) 3.4 meters 3.4 meters (50 degrees) | Weight of Lona 1.0 Ton Al 1.0 Ton | ‘The equipment was inspected based on ASMEVANSI B30.5 and the installed load chart 8 the actual testing, the boom truck was able to lift a tes load of 10 ton at a boom length of 5.3 meters long and was found to be stable at 3.4 meters ‘working radius. The test load was made to | hang for about fifteen (15) minutes stowly hoisting up and down and also the boon truck was made to swing forty five (45) degrees on both sides Magnetic particle inspection was also Conducted on the attached hook and results showed no visible discontinuity. ‘The boom truck was found tobe in satisfactory operating condition Se Note/Remark: none Aksersetoeenie: Nothing Roligwy tesisaeaccanentes Accredited Testing Organization - DOLE-BwC Accreditation No. 1410-18022318-0015 #283 Constancia St., Bgy, kati City, Tel, 899-0087 / 899-0465, Fax 896.7209 a CHEC CORPORATION CRANE ano HEAVY EQuiPMENT CERTIFICATION vcoreanttancin. Olympia, Makati 1207, Philippines tel: (+63 2) 899 0967 oe Gy vans can 2) 80 Accredited Testing Organization - DOLE-BWC Accreditation No. 1410-1802234 (Report Attachment -0015 as cnc CORPORATION CRANE AND HEAVY EQUIPMENT CERTIFICATION CORPORATION 8263 Constaicia, Olympla, Nakalj 1207, Philipines tel: (463 2} #99 0067 / 899 O46 Fax: (863 2] 896-7281 Accredited Testing Organization - DOLE-BWC Accreditation Mh, 1410-150130415-0015 ROOM LOADING CHART -F101854 WOKING RADI (om) 30 RATED LOAD —{) jended Guirigger | aa ‘WORKING RADIUS Jrncoanco none a CHEC CORPORATION CRANE ano HEAVY Equipment CERTIFICATION 8263 Constancia, Olympia, Makati 1207, Philippines tel: (+63 2) 899 0067 / 899 0465 Fax: (463 2) 896 728 Accredited Testing Organization - DOLE-BWG Accreditation No, 1410-18022318-0015 C CERTIFICATE Issued To 2 CME CONTRATORS, INC. Sta, Rita, Batangas City mm r] Test Conducted VISUAL EXAMINATION Location Corporation a P2-62 Dimacuha Rd., Sta, Rita, Batangas City Item Description 2 NYLON SLING Mfg. By: Technotex a Model (no data available) Serial No. : F038065, | Eqpt.ID- NS: a Car Gren Width 2 inches Length: 3 meters Long a Mfg. Year: (no data available) \ f 2 i Working Load Limit 2 Tons V r ‘Test Method/Standard ASME 830.9 i Safety Standard for Sling r Test Result : SATISFACTORY, a Note Inspect sting at least daily or before every 1 P and remove from service if damaged. | I certify that on July 21, 2020, a thorough visual examination for the equipment described above | was conducted. It was found to be in satisfactory condition. a Lalso certify that this is a true report of the result i Inspected By Noted By: , &oN/ IAP htiones sans PORTER, Ie Cg General Manager Certificate No. : CLA-2020-0692.B Valid Until July 20, 2021 / “The ermieon has noi one a nage conte yen fer. pense ‘shir uch pon ba ato Ianto mepigntyedrerpa fete he im ‘Stas or ony Ud pry swt sy otc ate i oe tne ager Sie the semitones ste cpr who ree he te 1s ented nthe renting enero, on td = as CHIEEC corporation CRANE ano HEAVY EQUIPMENT CERTIFICATION 4263 Constancia, Olympia, Makati 1207, Philippines tel: (463 2) 89%, 067 / 899 0465 Bax: (163 2 Accredited Testing Organization - DOLE-DWC ‘Accreditation No. 1410-18022918-0 CERTIFICATE Issued To CML CONTRATORS, INC. Sta. Rita, Batangas City AMINATION ‘Test Conducted “THOROUGH VISUAL Location CHEC Corporation P2-62 Dimacuha Rd, Sta, Rita, Batangas City Item Description NYLON SLING Mfg, By: Technotex Model: (no data available) Serial No, ; [037430 gp ID /NS21-01 Color Green Width inches: Length: 3 meters Long, ‘Mfg. Year: (no data available) Working Load Limit 2.Tons ‘Test Method/Standard ASME 130.9 Safety Standard for s ‘Test Result SATISFACTORY Z Ingpest sling at least daily or before every Ws Note and remove from service if damaged. | certify that on July 21, 2020, a thorough visual examination for the equipmenit described al ‘was conducted. It was found to be in satisfactory condition. { also certify that this is a true report of the result Inspected BY Noted By x \y say eIOnES {antes r roltre. Kes _ General Manager CertficateNo. = CLA-2020-0692.A Valid Until July 20, 2021 _// sey ow nsx rm come signet to ‘Theremin The rarer os ned tty meine 2 at et mse ey tad ay ite none rein tm torent crt ie iene an enon te rsa si ee rs cnet he fds el Tn KCl EC corporation CRANE ano HEAVY EQUIPMENT CERTIFICATION 8263 Constancia, Olympia, Makati 1207, Philippines tcl: (+63 2) 899 0067 / 899 0465 Fax: (+63 2) R96 7285 Accredited Testing Organization - DOLE-BWC Accreditation No. 1410-18022318-0015 CERTIFICATE Issued To CML CONTRATORS, INC. Sta, Rita, Batangas City Test Conducted : THOROUGH VISUAL EXAMINATION Location + CHEC Corporation P2-62 Dimacuha Rd., Sta. Rita, Batangas City Item Description : NYLON SLING Mfg. By = Technotex Model (no data available) : FOS80G., NS-27-03, Green 2 inches Length: 3 meters Long Mfg. Year: (no data avaitable) Working Load Limit 2Tons ‘Test Method/Standard : ASME 330.9 Safety Standard for Sling Test Result SATISEACTORY z, Note Inspect sling at least daily or before every use and remove from service if damaged. certify that on July 21, 2020, a thorough visual examination for the equipment described above was conducted, It was found to be in satisfactory condition. Lalso certify that this is a true report of the result. Noted By (a / om \ ‘anes F-PORTER, IR General Manager CertifieateNo, = CLA-2020-0692.C ‘Valid Until July 20, 2021 // “The cngniain ha oily eso damage cvs yt oan ier ees thr in st dr iment om he TREES felted ncntoety eneinets rd rrp other he ner dane i feed he company cot cae amc any td par hoo omy cote reben i he variant made ra tudor fomason en yo on bbe of ego. ‘Nor in case as metoned ie receding gap, cam he ial rns bbe pray eased he a daa eel i meme > af CHEC CORPORATION CRANE ano HEAVY EQuiPMENT CERTIFICA TION £263 Constancia, Olympia, Makati 1207, Philippines tol: (463 2) 899 0067 / 899 0465 Fax: (263 2) 896 774 Accredited Testing Organization - DOLE-BWC Accreditation No. 1410.190220 14 ors CERTIFICATE CMICONTRATORS, INC. Sta, Rita, Batangas City Issued To Test Conducted THOROUGH VISUAL EXAMINATION Location CHEC Corporation 2-62 Dimacuha Rd., Sta, Rita, Batangas City tem Description NYLON SLING Mfg. By — : Technotex Model (no data available) Setial No. : FO38054 Eqp.. iD NS-2T-04. Color Green width 2 inches Length: 3 meters Long, Mfg. Year : (no data available) Working Load Limit : 2Tons Test Method/Standard ASME 130.9 Safety Standard for Sling Test Result SATISFACTORY, Note ! Inspect sling at least daily or before every use and remove from service if damaged. I certify that on July 21, 2020, a thorough visual examination for the ‘equipment described above was conducted. It was found to be in satisfactory condition. Talso certify that this is a true report of the result Inspected Noted By: ~ €%/ J IES JAMES F. PORTER, JR Genefal Manager Certificate Valid Until July 20,2021 // secon te ai rx ee curd yi rp, tice, ep kes nt nde si fn te reat, Sree te tinal ends nl rpc of nek an eae eon a eee ae oe ‘uso’ etre any hid party ho wet ay coat recon sh organ ae ee ee eo ‘nade orifonrtn ten oon lf oe paion "erica menioned in the pct remark, ce il tind bv rsa ce te dogs eed abe. | af CHEC CORPORATION CRANE ano HEAVY EQUIPMENT CERTIFICATION 207, Philippines tel: (+63 2) 899 0067 / 899 0465 Fax: (+63 ” DOLE-BWC Accreditation No, 1410-18022318-001% | 8263 Constancia, Olympia, Makati | 2) 896 7283 Accredited Testing Organization Report Attachment a CHEC CORPORATION CRANE ano HEAVY EQUIPMENT CERTIFICATION 8263 Constancia, Olympia, Makati 1207, Philippines tel: (+63 2) 899 067 / 899 0463 Fax: (+63 2) 496 7284 Accredited Testing Organization - DOLE-BWC Accreditation No. 1410-18022310-0015 CERTIFICATE Issued To CMI CONTRATORS, INC. Sta. Rita, Batangas City Test Conducted THOROUGH VISUAL EXAMINATION AND MAGNETIC PARTICL TING Location CHEC Corporation P2-62 Dimacuha Rd., Sta. Rita, Batangas City Item Description SUACKLTE; BOLT TYPE Mfg. By: (no data available) Model: (no data available) EqpUD. | SBT-A7ST-O1 Size 3" Diameter Mf. Year: (no data availabe) Working Load Limit 4.75Tons 7 Test Method/Standard 180 2415 Forged Shackles for General Lifting Purposes Test Result : SATISRACTORY, Remark / Note none 1 certify that on December 09, 2019, a thorough visual examination and magnetic particle testing of item described above was conducted. It was found to be in satisfactory operating condition, Talso certify that the above is a true report of the result Inspected By: Noted By: 6 CLA.2019-1427.4 vadont oe esas, _/ ‘The ergsiato ins oly leo damage cased yo ete ech pees ae ily a : a CHEC CORPORATION CRANE ano HEAVY EQUIPMENT CERTIFICATION 8263 Constancia, Olympia, Makati 1207, Philippines tel: (+63 2) 899 0067 / 899 0465 Fax: (463 2) 896 7283 Accredited Testing Organization - DOLE-BWC Accreditation No. 1410-18022318-0015 CERTIFICAT Issued To CML CONTRATORS, INC. Sta, Rita, Batangas City Test Conducted THOROUGH VISUAL EXAMINATION AND MAGNETIC PARTICLE TESTING Location CHEC Corporation P2-62 Dimacuha Rd, Sta. Rita, Batangas City Item Description : SHACKLE; BOLT TYPE, Mfg. By (no data available) Model (no data available) EqpulD. — :SBT-A,757-02. ize 3/4" Diameter Mfg. Year: (no data available) Working Load Limit 2 4.75 Tons x ‘Test Method/Standard 1sO 2415 Forged Shackles for General Lifting Purposes ‘est Result : SATIS ACTORY, Remark / Note none 1 certify that on December 09, 2019, a thorough visual examination and magnetic particle testing of item described above was conducted. It was found to be in satisfactory operating condition Lalso certify that the above is true report of the result Inspected By: Noted By: TA.2019°1427.8 Valid. Unit” December 08, 2020 // Tye remizn ba obit orf or drag caed by topes, enlyee.o oes who et odes eter mich person ha ced intentional or wegizey an irpcr nhs he hanes eee ne ach _mpmatn'saastnes or ytd pat nin et any conti ln lhe sponta ‘nade formation ge bye nl natin "er fcso as mention inte preceding pmgap, canteen or ndinls who hee perma cond he oe damage el able af CHEC CORPORATION CRANE ano HEAVY EQUIPMENT CERTIFICATION 8263 Constoncia, Olympia, Makati 1207, Philippines tel: (+63 2) B99 0067 / 899 O4GS Fax: (463 2) 896 7284 Accredited Testing Organization - DOLE-BWG Accreditation No. 1410-18022310-0015 CERTIFICATE Issued To CMLCONTRATORS, INC. Sta. Rita, Batangas City ‘Test Conducted THOROUGH VISUAL EXAMINATION AND MAGNETIC PARTICLE TESTING Location CHEC Corporation P2-62 Dimacuha Rad., Sta, Rita, Batangas City Item Description SHACKLE; BOLT TYPE, Mfg. By (no data available) Model: (no data availabe) EqptID. : SDT-A,75T-03. Size A" Diameter Miz. Year: (no data avaitoble) Working Load Limit 475 'Tons Test Method/Standard 150 2415 Forged Shackles for General Lifting Purposes TORY, Test Result SATISF, Vy, Remark / Note none, | certify that on December 09, 2019, a thorough visual examination and magnetic particle testing of item described above was conducted. It was found to be in satisfactory operating condition, Talso certify that the above is a true report of the result Inspected By: Noted By. “Inspcloy , Manager Certificate N6——--CLA-2019-1427.C aid Vall December 8, 2020 / ‘Thesiger km dane ‘thr uh een bm tl ney vsioton's since ce ntl prty he inde or inforoatin steno etal en panriog ba cen lc, emloect.o hrs nt drei fn he craton reese ether th os ct demesne alc! the company others eve tree the non th theorists macnn ee i ‘rected te retin grr a te nen erin wo hess dh a damage el ae ) af CHEC CORPORATION CRANE ano HEAVY EQUIPMENT CERTIFICATION 8263 Constancia, Olympia, Makati 1207, Philippines tel: (+63 2) 899 0067 / 899 0465 Fax: (+63 2) 896 7281 Accredited Testing Organization - DOLE-BWG Accreditation No. 1410-18022318-0015 CERTIFICATE Issued To CMI CONTRATORS, INC. Sta, Rita, Batangas City Test Conducted ‘THOROUGH VISUAL EXAMINATION AND MAGNETIC PARTICLE TESTING. Location : CHEC Corporation P2-62 Dimacuha Rd, Sta, Rita, Batangas City Item Description SHACKLE; BOLT TYPE Mfg. By (no data available) Model (no data available) EqptlD. —: SBT-4.751-04_ Size 3/4" Diameter Mfg. Year : (no data avaiable) Working Load Limit 4.75 Tons Test Method/Standard Iso 2415 Forged Shackles for General Lifting Purposes ‘Test Result SATISFACTORY, Remark / Note 2 none Tertily that on December 09, 2019, a thorough visual examination and magnetic particle testing of tem described above was conducted, It was found to bein satisfactory operating condition Talso certify that the above is a true report of the result Inspected By: Noted by s E-PORTOR IR ci Aamre taro tieaber 02000 / Taeeraotion hs wo ats leo dng casey : ete mc person in sted italy r mepigets an nce eee i iy orate a naps eh ‘Tea’ cistne y an the party who witha ay earn saa ee Pomperear aes Sein em tos soem = npn, hn cede ale momen eee Nor inom mentioned nthe reg paragraph, eon ind exile eprom crnal helm ae ld ai a CHEC CORPORATION CRANE ano HEAVY EQUIPMENT CERTIFICATION 8263 Constancio, Olympia, Makati 1207, Philippines tel: (+63 2) 899 0067 / 899 0465 Fax: (463 2) 896 72 Accredited Testing Organization - DOLE-BWC Accreditation No. 1410-18022318-0016 Report Attachment gaan AANA opting, Republic of the Philippines uM Department of Labor and Employment a y iy TECHNICAL EDUCATION AND SKILLS DEVELOPMENT AUTHORITY, NATIONAL CERT HEO (TRUCK-MOUNTED CRANE) is awarded to Nd JUN A. NOCHE for having completed the competency requirements ander the Philippine TVET Competency Assessment and Certification System in the following units of competericy: Ur coDe ease courerences UNIT COE cone coMrENAICES 50011105 Parle wap comrunaon' CONRAD Fesinno an otonalinpemnebes {20511105 Wak bamenrument tr tg egret So03tH07 Pree cao probs COni3310.Petonbaceprereensiennce 500311108 Pacino eho say tenth er ny ont Prete conen3512 Pater pdscvecperton br Tock . eamod Crone ‘vw cOOE conor COMPETENCES CoveGt201 Prep ansineten mer eos ‘CONSSION Obs poceaes spots end ronnie neocon Const ee ec ang and ans Conze%0 Porte measratne ad clans (CONSSI2N Manian tos ons Signature of the certificate holder Issued on ; December 07, 2015 Certificate No, 15131202054723 Valid until: December 06, Oe ot AA gy - SEC. IRENE MI. ISAAC Dicer Een nt ace. ASSOCIATION OF CARRIERS & EQUIPMENT LESSORS, INC. Suite 160, Jolibee laza Condominium, F- Ortigas, Je Road, Ortign Center, Pasig City Philip Tel. No 6313136" Telefax No. 6334994 I Website: wormace.com. ph Emma ecretari@acel.com.ph / acel_(@yahoo.com CERTIFICATION JUN A. NOGHE who has successfully passed the Competency and ‘Trade Test for TRUCK MOUNTED CRANE OPERATOR NC Il conducted on November 15, 2015 at Carlos M. Iagan (Contractor), Inc. Yard, Sta. Rita, Batangas City Given this 16 day of November 2015, in the City of Pasig, Phi i Cae ‘T. BENEDICT! \ JOVITO P. BASILIO Chairman, Manpower Dev't & Certification President ee AAA Republic of the Philippines om Department of Labor and Employment y f TECHNICAL EDUCATION AND SKILLS DEVELOPMENT AUTHORITY RIGGING is awarded to FELIX D. CUNAG for having completed the competency requirements under the Philippine TVET Competency Assessment aunt Certification System in the fo lowing units of competericy UNIT CODE. BASIC COMPETENCIES UWITCODE CORE COMPETENCES 00911105 Pacts inwerplow communion CONV21901 inspect aig eas 00311105 Wak bamenitoanen ‘coN21202 Intl iggy goa 500311107 Proctes crer pester (001721203 Asis cane oper 500911108 Practice ccapstonalsth ee sale Procedues UNITCODE COMMON ComPETENCIES CCOWES1201 Prepare consucfn mater and toa CCONI31201| Cbsnweprocecxes spcteaonsand raul oncom {0011831202 triset ical drains on plans COW381203 Perlrmmeasiraens wi caine CCONSSIZ04 Main oot and eqapmens November 21, 2015 Signature of the certificate holder uedon : Certificate No, 15131201060712 Valid until: November 20, 2029" mam SEC, IRENE MI. ISAAC r Direcor General Bins: CLN-NQ- 0475038 vn GUNAG, FELIX C ace. ASSOCIATION OF CARRIERS & EQUIPMENT LESSORS, INC. Suite 160, Jolibee Pass Condominium, F. Ortigas, J, Road, Ontgas Center, aig Ci, Philippines ‘Tel. Now 6313136 * Telefax No 633.4904 Websites wtacel-com ph Email seertarar@scel.com.ph / acl_i@yahoo.com ‘This CERTIFICATION FEDIX D. GUNAG who has successfully passed the Competency and ‘Trade ‘Test for RIGGING NC I conducted on November 15, 2015 at Carlos M. Magan (Contractor), Inc. Yard, Sta Batangas City Given this 16" day of November 2015, in the City of Pasig, Philippines. a SIXTO T. BENEDICTO (x VITO P. BASILIO. airman, Manpower Dev't & Certification President | |

You might also like