CARESCAPE Telemetry T4 Transmitter: Reliable Wireless Patient Monitoring
CARESCAPE Telemetry T4 Transmitter: Reliable Wireless Patient Monitoring
CARESCAPE Telemetry T4 Transmitter: Reliable Wireless Patient Monitoring
T4 Transmitter
Reliable wireless patient monitoring
The ApexPro® telemetry system delivers proven reliability Built for durability and ease-of-use, CARESCAPE™ Telemetry
and innovative clinical technology that reduces the possibility T4 transmitters provide a 110-hour battery life, excellent
of transmission interference, dropout and downtime. fluid-ingress protection and the event marker feature.
ApexPro can be used effectively for either centralized The ApexPro telemetry system is scalable, allowing you
or decentralized monitoring. to accommodate today’s requirements and prepare for
future expansion.
Features
Advanced arrhythmia monitoring
• Dual V-Leads enhance monitoring for arrhythmia
and ST segment changes
GE EK-Pro™
• 4-lead simultaneous arrhythmia detection exceeds
AHA standards and an innovative Smart Leads Fail
feature significantly reduces false ECG alarms1
Pacemaker detection
• 2-vector analysis ensures accurate pace detection
Monitoring flexibility
• Flexible design allows each transmitter to monitor
parameters according to patient acuity.
CARESCAPE V100 and GE DINAMAP® monitors
can interface to the CARESCAPE Telemetry
T4 transmitter using the DinaLink™ interface
cable for episodic monitoring of SpO2, NIBP
or Temperature
• CARESCAPE Telemetry T4 transmitter provides
up to 110 hours of operation on two AA alkaline
batteries for a lower overall cost of ownership
Reference:
1.
“Ventricular Arrhythmia Detection Performance of Two Commercially
Available Patient Monitors Using Previously Unpublished ECG Waveforms.”
Nicole Haupt, BSEE; Jennifer A. Bowman, MSEE; Jennifer Salvo, BSCE;
David A. Sitzman, MSEE; R. Gary Earl, PhD; and George M. Hutchinson, PhD.
Multi-channel I, II, III, Va, Vb, aVR, aVL, aVF Lead fail indication Transmitted and indicated via LEDs
configuration
Alarm pause indicator Transmitted and indicated via LED
(5 or 6 leadwire)
Graph request Transmitted
Leads analyzed Four (I, II, III, V)
simultaneously Event marker button Transmitted
Single-channel I, II or III, configurable Verify leads button Indicated via LEDs
(3-lead) configuration
Storage conditions
Temperature -40°C to 70°C
About GE Healthcare
GE Healthcare provides transformational medical
technologies and services that are shaping a new age of
patient care. Our broad expertise in medical imaging and
information technologies, medical diagnostics, patient
monitoring systems, drug discovery, biopharmaceutical
manufacturing technologies, performance improvement
and performance solutions services help our customers
to deliver better care to more people around the world
at a lower cost. In addition, we partner with healthcare
leaders, striving to leverage the global policy change
necessary to implement a successful shift to sustainable
healthcare systems.
Our “healthymagination” vision for the future invites
the world to join us on our journey as we continuously
develop innovations focused on reducing costs, increasing
access and improving quality around the world.
Headquartered in the United Kingdom, GE Healthcare is a
unit of General Electric Company (NYSE: GE). Worldwide,
GE Healthcare employees are committed to serving
healthcare professionals and their patients in more than
100 countries. For more information about GE Healthcare,
visit our website at www.gehealthcare.com.
GE Healthcare
P.O. Box 900, FIN-00031 GE, Finland
Tel. +358 10 394 11
Fax +358 9 146 3310
www.gehealthcare.com