GENERAL NOTES NOTES ON PIPE PENETRATIONS:

ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE


EXECUTED ACCORDING TO THE PROVISIONS OF THE SLEEVE SHALL BE PROVIDED AROUND ALL
PHILIPPINE PLUMBING CODE, THE NATIONAL BUILDING PIPING EXTENDING THROUGH WALLS, FLOORS
CODE, AND THE RULES AND REGULATIONS OF ANTIPOLO CITY. PLATFORMS AND FOUNDATIONS
COORDINATE THE DRAWING WITH OTHER RELATED
A. MINIMUM CLEARANCE BETWEEN PIPE AND SLEEVE
DRAWINGS AND SPECIFICATIONS. THE ENGINEER SHALL
SHALL NOT BE LESS THAN 25 mm FOR PIPES 25 mm
BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND
HEREIN. THROUGH 90mm AND 50mm FOR PIPES 100mm
LARGER.
ALL PIPES SHALL BE INSTALLED AS INDICATED ON
PLANS. ANY RELOCATIONS REQUIRED FOR PROPER B. THE CLEARANCE BETWEEN THE PIPE SLEEVE
EXECUTION ON OTHER TRADES SHALL BE WITH PRIOR SHALL BE FILLED WITH NON COMBUSTIBLE FIRE 1 WATER METER DETAIL
APPROVAL OF THE ARCHITECT OR ENGINEER. P-1 SCALE NTS
INTUMESCENT COMPUND SIMILAT TO "PROMAT",
PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE OR "HILTI" PIPES PENETRATION SHALL NOT
ACTUAL LOCATION DEPTHS AND INVERT ELEVATIONS OF DECREASE FIRE RATING OF WALLS AND FLOORS. 3 INSIDE GUTTER DET.
P-1 SCALE NTS
ALL EXISTING PIPES AND STRUCTURES VERIFIED BY C. FLOOR SLEEVES SHALL BE EXTENDED AT LEAST 75 mm
THE CONTRACTOR. FLOOR DRAIN FLOOR CLEAN OUT
ABOVE THE TOP OF THE WEARING SURFACE.
ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL
MAINTAIN 0.5%.FOR SEWER SHALL BE 1.5 % MINIMUM
UNLESS OTHERWISE SPECIFIED.

SIZES OF WATER SUPPLY PIPES TO FIXTURES SHALL BE


IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.

THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES


AT SITE AND COORDINATE THE WORKS WITH THE SEWER
EFFLUENT DISPOSAL POINT AND WATER LINE
SERVICE CONNECTING POINT.

ALL PIPE SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS


ARE IN METERS UNLESS OTHERWISE SPECIFIED.
2 FLOOR DRAIN & FLOOR CLEAN OUT
P-1 SCALE NTS

MATERIAL SPECIFICATION
LENGTH "L"
INCOMING COLD WATER SUPPLY PIPE TO DWT/FWT SHALL BE G.I. SCH. 40 SEAMLESS 4 CATCH BASIN DETAILS
P-1 SCALE NTS
ALL RISER & LOOPED MAINS SHALL GALVANIZED IRON PIPE SCHEDULE 40 450 MM
CONFORMING TO ASTM A-120 APO,SUPER OR APPROVED EQUAL.
ROUGHING-IN FOR TOILETS SHALL BE PPR PIPES PN 20 AS SIMILAR TO
SEPTIC VAULT SCHEDULE
REHAU,ALFAIDRO,JORGE FISCHER OR APPROVED EQUAL.
MANHOLE MANHOLE MANHOLE

SOIL,DRAINAGE AND VENT PIPING SHOULD BE OF UPVC PIPES AND FITTINGS 450 MM
CONFORMING TO ASTM D2729 AND ASTM D3311 RESPECTIVELY OR 450 MM
FOR PIPES CONFORMING TO PNS 1950 S-1000 TABLE 2A WALL THICKNESS
(INCH BASED SERIES) SIMILAR TO NELTEX SEWERGUARD OR APPROVED EQUAL.

AND FOR SIZES 160mm AND UP OF UPVC PIPES & FITTING CONFORMING
TO ISO 4435. THERMOFORMED FITTING FOR SIZES 250mm AND UP.
CO
SIMILAR TO NELTEX SANIGUARD OR APPROVED EQUAL.
LEGENDS AND SYMBOLS:
JOINTING SHALL BE BY PVC PIPE CEMENT CONFORMING TO ASTM D2654. AIR SPACE AIR SPACE AIR SPACE
INLET 300 MM STORM DRAINAGE SYSTEM:
SIMILAR TO NELTEX OR APPROVED EQUAL. OUTLET WATER DISTRIBUTION SYSTEM: WASTE, SEWER, AND VENT SYSTEM:
COLD WATERLINE ABOVE CEILING DRAIN PIPE
SOIL PIPE / WASTE PIPE
LEACHING LEACHING
DIGESTIVE CHAMBER CHAMBER VENT PIPE ABOVE CEILING
CEILING CLEAN-OUT
RISER UP / RISER DOWN
SHALL BE ALL BRASS BADGER, ARAD, ASAHI CHAMBER
FLOOR CLEAN OUT DOWNSPOUT
GATE VALVE
CATCH BASIN / AREA DRAIN
WATER METER VENT STACK THRU DECK / SOIL STACK

CLASS 150-SIMILAR TO KITZ, CRANE, NIBCO, OR APPROVED EQUAL. CHECK VALVE FLOOR DRAIN

HOSE BIBB VENT PIPE

SITE STORM DRAINAGE LINE

5 SEPTIK VAULT DETAIL


P-1 SCALE NTS

ENGINEER : PROJECT TITLE: SHEET CONTENTS: DESIGNED BY: OWNER: SHEET NO.:
GENERAL NOTES AND LEGENDS CHECKED BY:
PROPOSED 2-STOREY RESIDENTIAL SANITARY/PLUMBING DRAWING DETAILS

PRC NO.: PTR NO.: LOCATION:


BILIRAN ROAD LEMON,LEYTE
DECODED BY:

DATE: