Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

5/25/2021 An Overview of FDA Regulations for Medical Devices

Blog Media Resources Global Presence Careers

An Overview of FDA
Regulations for Medical
Devices
FEBRUARY 22, 2018 BY ANAND BORAD HEALTHCARE READING TIME: 8 MINUTES

F o r d e v e l o p i n g m e d i c a l d e v i c e s i n t h e U S A , m a n u f a c t u re r s a n d
d i s t r i b u t o r s m u s t h a v e a c o m p l e t e u n d e r s t a n d i n g t h e re g u l a t i o n s a n d
c o m p l i a n c e s . T h i s b l o g p ro v i d e s a d e t a i l e d o v e r v i e w o f t h e F D A
re g u l a t i o n s f o r m e d i c a l d e v i c e s .

When it comes to the medical device industry, you must know about medical device regulations, if you are
serving the industry, since it is more of compliance and regulation-driven industry.

Whatever technological advancement and innovation you can bring to the medical device industry (whether it is
being able to transform the industry operations or it is powerful enough to put the care delivery professionals
years ahead of the time), must go through complex compliances and regulations procedures because the bottom
line is the safety and effectiveness of the medical devices.

Here is the overview of medical device regulations you need to know before beginning the medical device design
process.

Medical Device Regulations in the USA


We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Privacy Policy and Cookie Policy.

Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 1/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

In the USA, medical devices are regulated by the Food and Drug Administration (FDA) with an aim to ensure
safety and effectiveness of the devices. The Center for Devices and Radiological Health (CDRH) is an FDA
component and looks after this program.

Medical devices are classified into three categories based on the associated risk, namely: Class I, II and III. Class
I devices will have least associated risk while class III devices will have the highest associated risk. Accordingly,
regulatory control surges from Class I devices to Class III devices.

With respect to that, most of Class I devices are exempted from 510(k) premarket notification submission, while
most of Class II devices are submitted for premarket notification. On the other hand, Class III devices need to go
through the Premarket Approval Application (PMA) and other class III devices, which are exempted from PMA
must submit a 510(k) notification to FDA.

Types of FDA Regulations for Medical Devices

Let’s look at the basic regulations that US-based manufacturers and distributors must comply with and understand
them one by one.

1. Establishment Registration & Medical Device Listing – 21 CFR Part 807

2. Premarket Notification 510(k) – 21 CFR Part 807 Subpart E

3. Premarket Approval (PMA) – 21 CFR Part 814

4. Investigational Device Exemption (IDE) for clinical studies – 21CFR Part 812

5. Quality System (QS) regulation 21 CFR Part 820

6. Labeling requirements – 21 CFR Part 801

7. Medical Device Reporting (MDR) – 21 CFR Part 803

1. Establishment Registration & Medical Device Listing – 21 CFR Part 807

All the medical device manufacturers and distributors must register their organization with FDA to sell their
devices. Unless it is granted by the FDA, all the establishments should be registered electronically using the FDA
Unified Registration and Listing System (FURLS system).
It is mandatory to verify registration information every year. Although FDA provides flexibility for verification,
you can verify your information anytime from October 1st to December 31st of every year. FDA charges a
significant amount of fees for registration and revises the fees periodically.
We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Privacy Policy and Cookie Policy.

Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 2/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

Additionally, foreign manufacturers must have a U.S. Agent. They may hire a U.S. agent as their official
correspondent, but that is totally up to the foreign manufacturer. They only need to provide primary details of the
U.S. agent such as name, number, email ID and physical address. The U.S agent needs to confirm that s/he has
agreed to act as an official correspondent for the manufacturer. If the designated U.S. agent fails to confirm within
10 business days, the concerned foreign manufacturer needs to designate a new agent.

Under medical device listing requirement, organizations also need to provide details of devices they are
manufacturing. They need to provide a premarket submission number for the device such as 510(k), PMA
(Premarket Approval), HDE (Humanitarian Device Exemption), etc. to FDA if it requires premarket procedures.

For #MedicalDevice listing, you must provide a premarket submission


number for the device such as 510(k), PMA, HDE, etc. to #FDA.

2. Premarket Notification 510(k) – 21 CFR Part 807 Subpart E

All the medical devices which are intended for human use regardless of its class must submit premarket
notification excepting two cases:

1. Devices for which Premarket Approval Application (PMA) is not required

2. Devices which are exempted from 510(k) notification of the FDA considering applied limitation

Here, most of Class I devices are exempted from 510(k) notification, while some of these devices need to submit
the notification. Manufacturers must submit 510(k) notification for all Class II devices, which do not need to go
through Premarket Approval.

For each device with 510(k) notification submission, a manufacturer must receive a clearance order before they
commercially start distributing the device. The FDA provides this order in the form of a letter and specifies that
the device is substantially equivalent (SE) and is safe and effective as the existing legally marketed devices.
Generally, it takes 90 days to receive clearance order from the FDA. However, it depends on the information
submitted by the manufacturer.

To mark a device as substantially equivalent, manufacturers need to compare their device with one or multiple
existing devices and provide suitable facts to support the claim. The base device selected for the comparison is
called as “predicate”. Any available device which does not violate any of the FDA acts can be used as a predicate,
including devices which recently cleared 510(k) notification.
We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Privacy Policy and Cookie Policy.

Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 3/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

So the question is how does the FDA decide that the device is substantially equivalent (SE)? Here is the
explanation:

A device is considered as SE in the following two scenarios, while comparing it with the predicate:

1. A device has the same proposed use with the same technological features as the predicate.

2. A device has the same proposed use as the predicate with different technological features, but that
does not raise different questions on safety and effectiveness of the device, and the information
submitted by a manufacturer is sufficient enough to validate that the device is at least as safe and
effective as the existing legally marketed device.

It seems like the device and predicate are identical, but it’s not. Substantial equivalence is established with respect
to the intended use, design, materials, energy used or delivered, manufacturing process, chemical composition,
safety, performance, biocompatibility, standards, effectiveness, labeling, and other characteristics, as applicable.

3. Premarket Approval (PMA) – 21 CFR Part 814

Premarket approval is the scientific review process designed by the FDA for the safety and effectiveness
evaluation of medical devices. All the Class III devices must go through PMA considering associated high risks.

Also, several Class II devices need to go through PMA. There are two scenarios where PMA is mandatory for a
Class II device.

1. If a manufacturer thinks that their device is not substantially equivalent and cannot find suitable
predicate; and

2. Manufacturer applies for 510(k) submission with the predicate, but it gets rejected by FDA stating
that the device is not substantially equivalent.

Premarket approval is a tough requirement where the applicant must get an approval for PMA application before
starting any marketing activities. Whether to approve the PMA or not, depends on the provided scientific
evidence assuring that the device is safe and effective for the proposed use specified in the application.

HANDPICKED CONTENT
FAQs on Medical Devices
We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Privacy Policy and Cookie Policy.

Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 4/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

According to the regulation, it should take 180 days to approve or reject the PMA application, but in reality, it
takes longer most of the time.

Once the applicant (an individual, organization or organizational unit, association, private or government
establishment or any other kind of legal entity) submits the PMA, the FDA will send the application to the
appropriate advisory committee for review at a public meeting. The committee will provide the recommendation
and facts supporting whether to approve or reject the application.

Once the FDA determines the submission, they notify the applicant that their application has been approved or
rejected. And then FDA publishes a notice on their website with the aims of

1. Announcing the data on which the decision is based, and

2. Providing interested persons an opportunity to petition FDA within 30 days for reconsideration of
their decision.

On completion of a successful PMA process, an approval in the form of a private license granting the applicant a
permission to market the device is released.

4. Investigational Device Exemption (IDE) for Clinical Studies – 21CFR Part


812

Investigational Device Exemption (IDE) is a provision that allows manufacturers to collect device-specific safety
and effectiveness data for the proposed device before commercialization, which can be used to support premarket
approval application or in some cases for premarket notification submission.

Safety and effectiveness data are collected by monitoring a provisioned device for the intended use. Apparently,
IDE is mandatory for devices which are unable to get marketing clearance using 510(k) notification and PMA
applications.

There are several base-line requirements to proceed with IDE. It includes:

an investigational plan approved by an IRB – institutional review board (in case if the study
involves a significant risk device, the IDE must also be approved by FDA);

informed consent from all patients;

labeling stating that the device is for investigational use only;

monitoring of the study and;


We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
all the records and reports. Privacy Policy and Cookie Policy.

Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 5/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

For 510(k) notification, FDA needs clinical data to provide marketing clearance in very limited cases. An
approved IDE application provides rights to lawfully ship the devices for investigation purpose without forcing
other FDA needs that are required for device commercialization.

A manufacturer must submit complete IDE application to FDA. Although, it does not have a pre-determined
format, but they are bound to imply certain information in the form, such as sponsor investigator information,
clinical plan overview, investigational plan method and controls information.

5. Quality System (QS) Regulation 21 CFR Part 820

The quality system specifies the regulatory requirements related to the methods, facilities, and controls used for
the entire medical device lifecycle, including the purchasing, designing, manufacturing, packaging & labeling,
storing, installing and servicing of the devices.

The FDA mandates to establish and follow quality system requirements for manufacturers to ensure that the
devices meet applicable requirements and specifications consistently.

The FDA quality system is named as current good manufacturing practices (CGMPs) and forced under part 820
(21 CFR part 820), authorized by section 520(f) and became effective on December 18, 1978.

The #FDA mandates to follow quality system regulations known as


#CGMP (current good manufacturing practices) to ensure that
#medicaldevices meet regulatory compliance

1. (ISO) 9001:1994 “Quality Systems–Model for Quality Assurance in Design, Development,


Production, Installation, and Servicing”

2. ISO/CD 13485 “Quality Systems–Medical Devices–Supplementary Requirements to ISO 9001

FDA published the part 820 revision on October 7, 1996 (61 FR 52602) and put into effect June 1, 1997.

Considering the multiple types of medical devices, the regulation does not provide “how to’s” for a specific
device, but it, in fact, provides a framework that manufacturers need to follow to comply with the regulation.

We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Also, to ensure that all requirements are followed, FDA inspects all manufacturing facilities as well. Every
Privacy Policy and Cookie Policy.
manufacturer is responsible for establishing the regulatory requirements to make the device safe and effective
Accept Terms Read more
regardless of the type of device. This regulation applies to all the finished device manufacturers who intend to

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 6/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

commercially distribute medical devices in the United States. A finished device is any device that is suitable for
use or capable of functioning, whether or not it is labeled, packaged, or sterilized.

6. Labeling Requirements – 21 CFR Part 801

It is mandatory to apply labels on each device. Labeling contains labels and literature in the form of description
and information that accompanies the device usage.

This regulation specifies the requirements in the below form:

General Device Labeling

Use of Symbols

In Vitro Diagnostic Products

Investigational Device Exemptions

Unique Device Identification

Good Manufacturing Practices

General Electronic Products

FDA defines a label as

‘display of printed, written or graphic matter upon the immediate container of any article…’

and

‘all labels and other written, printed, or graphic matter

(1) upon any article or any of its containers or wrappers, or


(2) accompanying such article’ at when a device is held for sale after shipment or delivery for shipment in
interstate commerce.

HANDPICKED CONTENT
Medical Device Design and Development: A Guide for Medtech Professionals

We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Privacy Policy and Cookie Policy.
7. Medical Device Reporting (MDR) – 21 CFR Part 803
Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 7/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

In several cases where a medical device causes a death or a serious injury or in case of certain device
malfunction, it is required to report FDA for the same.

The goal of this regulation is to timely detect and correct problems by identifying and monitoring significant
negative effects of a particular medical device. Here are the reporting rules to be followed by manufacturers,
importers and medical facility owners:

1. Manufacturers: Manufacturers need to report to the FDA using 3500A form when they identify that
their device caused death or serious injury. They are also bound to inform the FDA when some
serious malfunction happens which may cause a death or a serious injury and there is a possibility
that this may happen again.

2. Importers: Importers need to inform FDA as well as manufacturers in case of death or injury. While
for device malfunction, they need to report to manufacturers only.

3. Healthcare Facility: When a facility (hospital, ambulatory surgical facility or nursing home), where
a medical device is being used detects that some device would have caused a death, they need to
inform FDA and manufacturer as well. It is okay not to report for device malfunction, but they can
voluntarily inform the FDA about such product malfunctions through MedWatch.

You can refer FDA website for specific information about FDA regulation. However, before you start
your medical product development, you must definitely get an overview of the FDA regulations for medical
devices.

Looking for more information? Download our research on Medical Device Designers.

eInfochips has hands-on engineering experience in developing FDA Class II and Class III devices for monitoring,
diagnostics & imaging, wearable health, and telemedicine. We provide HIPAA compliant engineering solutions
and have the required process expertise in IEC 60601-1/2/6, IEC 62304, 510K and ISO 13485. Know more
about medical devices engineering services.

ABOUT THE AUTHOR

ANAND BORAD

Anand Borad works as senior marketing executive and takes care of digital and content
marketing efforts for Medical devices, Connected Retail & Healthcare and New product
development initiatives. He enjoys learning newer technologies and adopting it into everyday
marketing
We've updated our privacy policy. practices.
Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Privacy Policy and Cookie Policy.

Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 8/9


5/25/2021 An Overview of FDA Regulations for Medical Devices

RELATED POSTS

Infusion Devices: The Future of Better Care Connected Care Solutions for Developing Wi-F
Delivery Countries New
JULY 16, 2015 BY RENJITH PONNAPPAN MAY 8, 2015 BY RENJITH PONNAPPAN AUGU

©2020 eInfochips (an Arrow company), all rights reserved. Terms and Conditions | Know more about
eInfochcips's Privacy Policy and Cookie Policy

We've updated our privacy policy. Please take a moment to review these changes. By clicking I Agree, you agree to Arrow Electronics
Privacy Policy and Cookie Policy.

Accept Terms Read more

https://www.einfochips.com/blog/an-overview-of-fda-regulations-for-medical-devices/#:~:text=Under medical device listing requirement,if it require… 9/9

You might also like