TECHNICAL DATA FOR BOILER UNIT 736082,-84#01.

Technical data for boiler unit

1 General data

 Project No.:...........................................................................736082, 736084


 Hull No.:.......................................................................................5195, 5196
 Classification society:......................................................................LRS, IRS
 Pressure gauge calibration:..................................................................kg/cm2
 Thermometer calibration:...........................................................................°C
 Language for signs:...................................................................................UK

2 Dimensions for boiler unit

 Height to top of local control panel:...............................................9,484 mm


 Diameter incl. insulation:................................................................3,870 mm
 Total height incl. retraction of burner lance:.................................10,600 mm
 Weight of boiler unit excl. water:....................................................41,900 kg
 Weight of boiler unit incl. water:....................................................57,800 kg

3 Water/steam process data

 Steam output:...............................................................................40,000 kg/h


 Working pressure:................................................................. 7.0/16.5 kg/cm2
 Max. allowable working pressure:...............................................18.5 kg/cm2
 Blow off capacity safety valve No. 1:..........................................30,050 kg/h
 Blow off capacity safety valve No. 2:..........................................30,050 kg/h
 Working temperature:...........................................................................205°C
 Feed water operation:...................................................................modulating
 Feed water temperature, operation:...................................................85-95°C
 Feed water temperature, layout:..............................................................60°C

4 Combustion process data

 Min. calorific value of diesel oil:................................................42,200 kJ/kg

Language UK Page 1/4


TECHNICAL DATA FOR BOILER UNIT 736082,-84#01.0

 Min./max. viscosity of diesel oil:..........................................3/12 cSt at 50°C


 Density of diesel oil:.......................................................................890 kg/m3
 Min. calorific value of fuel oil:....................................................40,200kJ/kg
 Max. viscosity of fuel oil:......................................................700 cSt at 50°C
 Density of fuel oil:..........................................................................980 kg/m3
 Fuel oil temperature before pre-heater:...................................................50°C
 Fuel oil viscosity at burner inlet:...........................................................15cSt
 Fuel oil temperature at burner inlet:......................................................140°C
 Ambient air temperature:........................................................................45°C
 Air excess No. at 100% load:...................................................................1.15
 Flue gas temperature (clean boiler):.....................................................398°C
 Air consumption at 100% load:....................................................47.277 kg/h
 Flue gas flow (approx.):...............................................................50.329 kg/h
 Pressure loss across pin elements:...............................................284 mmWC
 Expected back pressure from stack at full load:............................15 mmWC

5 Data for atomising steam

 Atomising steam pressure at burner, max.:....................................6.0 kg/cm2


 Atomising steam consumption, max.:...............................................150 kg/h
 Atomising air pressure at burner, max.:.........................................7.0 kg/cm2
 Atomising air consumption, max.:....................................................270 kg/h

6 Data for electric systems

 Power supply:.......................................................................3 x 440V, 60 Hz


 Control voltage:....................................................................1 x 220V, 60 Hz
 Pilot voltage:............................................................................................24V
 Insulation class:............................................................................................F
 Degree of protection:...............................................................................IP44
 Colour of local control panel:..........................................Munsell 7.5 BG 7/2
 Colour of power panel:....................................................Munsell 7.5 BG 7/2

7 Data for pressure part

 Boiler type:....................................................................Large oil fired boiler


 Model:........................................................................MISSION OL 40000

Language UK Page 2/4


TECHNICAL DATA FOR BOILER UNIT 736082,-84#01.0

 Test pressure:...............................................................................27,0 kg/cm2


 Max. allowable shrink:.....................................................................0,635 m3
 Max. allowable swell:.......................................................................1,319 m3
 Number of pin elements:.............................................................................98
 Protection of boiler body:........................................................trapezoid plate
 Colour of insulation plates:................................................hot dip galvanized

8 Data for burner

 Burner type:......................................................Steam atomising, modulating


 Model:.........................................................................................KBSD 3000
 Burner capacity on diesel oil, min./max.:.................................300/2797 kg/h
 Burner capacity on fuel oil, min./max.:....................................300/2936 kg/h
 Colour of burner................................................................................standard

9 Data for water level operation

 Too high water level alarm:.............................................................+165 mm


 High water level warning:...............................................................+135 mm
 Normal water level:...............................................................................0 mm
 Start stand-by feed water pump:....................................kg/cm2/not AI supply
 Low water level warning:.................................................................-145 mm
 Too low water level alarm and burner off:.......................................-190 mm
 Too low water level alarm and burner off:.......................................-190 mm

10 Data for steam pressure operation

 Safety valve:................................................................................18.5 kg/cm2


 Safety valve:................................................................................18.5 kg/cm2
 High steam pressure alarm and burner off:..................................18.3 kg/cm2
 High steam pressure warning:......................................................18.0 kg/cm2
 Steam dump opening pressure:.......................................................xx kg/cm2
 Burner start/stop high pressure:...........................................16.7/17.7 kg/cm2
 Burner start/stop low pressure:................................................7.2/8.2 kg/cm2
 Burner operation:...................................................................7.0/16.5 kg/cm2
 Low steam pressure warning:........................................................4.0 kg/cm2

Language UK Page 3/4


TECHNICAL DATA FOR BOILER UNIT 736082,-84#01.0

11 Manuals

 Language for manuals:..............................................................................UK


 Set of instruction manuals:....................................................................5/ship
 Document revision date:............................................................07 JAN 2004

Language UK Page 4/4