This document provides technical data for a boiler unit including:
1. General data such as the project number, hull number, classification society, and sign language.
2. Dimensions and weights for the boiler unit such as its height, diameter, total height, and weights excluding and including water.
3. Water/steam process data like steam output, working pressures, temperatures, and feed water details.
This document provides technical data for a boiler unit including:
1. General data such as the project number, hull number, classification society, and sign language.
2. Dimensions and weights for the boiler unit such as its height, diameter, total height, and weights excluding and including water.
3. Water/steam process data like steam output, working pressures, temperatures, and feed water details.
This document provides technical data for a boiler unit including:
1. General data such as the project number, hull number, classification society, and sign language.
2. Dimensions and weights for the boiler unit such as its height, diameter, total height, and weights excluding and including water.
3. Water/steam process data like steam output, working pressures, temperatures, and feed water details.
This document provides technical data for a boiler unit including:
1. General data such as the project number, hull number, classification society, and sign language.
2. Dimensions and weights for the boiler unit such as its height, diameter, total height, and weights excluding and including water.
3. Water/steam process data like steam output, working pressures, temperatures, and feed water details.
Hull No.:.......................................................................................5195, 5196 Classification society:......................................................................LRS, IRS Pressure gauge calibration:..................................................................kg/cm2 Thermometer calibration:...........................................................................°C Language for signs:...................................................................................UK
2 Dimensions for boiler unit
Height to top of local control panel:...............................................9,484 mm
Diameter incl. insulation:................................................................3,870 mm Total height incl. retraction of burner lance:.................................10,600 mm Weight of boiler unit excl. water:....................................................41,900 kg Weight of boiler unit incl. water:....................................................57,800 kg
Working pressure:................................................................. 7.0/16.5 kg/cm2 Max. allowable working pressure:...............................................18.5 kg/cm2 Blow off capacity safety valve No. 1:..........................................30,050 kg/h Blow off capacity safety valve No. 2:..........................................30,050 kg/h Working temperature:...........................................................................205°C Feed water operation:...................................................................modulating Feed water temperature, operation:...................................................85-95°C Feed water temperature, layout:..............................................................60°C
4 Combustion process data
Min. calorific value of diesel oil:................................................42,200 kJ/kg
Language UK Page 1/4
TECHNICAL DATA FOR BOILER UNIT 736082,-84#01.0
Min./max. viscosity of diesel oil:..........................................3/12 cSt at 50°C
Density of diesel oil:.......................................................................890 kg/m3 Min. calorific value of fuel oil:....................................................40,200kJ/kg Max. viscosity of fuel oil:......................................................700 cSt at 50°C Density of fuel oil:..........................................................................980 kg/m3 Fuel oil temperature before pre-heater:...................................................50°C Fuel oil viscosity at burner inlet:...........................................................15cSt Fuel oil temperature at burner inlet:......................................................140°C Ambient air temperature:........................................................................45°C Air excess No. at 100% load:...................................................................1.15 Flue gas temperature (clean boiler):.....................................................398°C Air consumption at 100% load:....................................................47.277 kg/h Flue gas flow (approx.):...............................................................50.329 kg/h Pressure loss across pin elements:...............................................284 mmWC Expected back pressure from stack at full load:............................15 mmWC
5 Data for atomising steam
Atomising steam pressure at burner, max.:....................................6.0 kg/cm2
Atomising steam consumption, max.:...............................................150 kg/h Atomising air pressure at burner, max.:.........................................7.0 kg/cm2 Atomising air consumption, max.:....................................................270 kg/h
6 Data for electric systems
Power supply:.......................................................................3 x 440V, 60 Hz
Control voltage:....................................................................1 x 220V, 60 Hz Pilot voltage:............................................................................................24V Insulation class:............................................................................................F Degree of protection:...............................................................................IP44 Colour of local control panel:..........................................Munsell 7.5 BG 7/2 Colour of power panel:....................................................Munsell 7.5 BG 7/2
Model:.........................................................................................KBSD 3000 Burner capacity on diesel oil, min./max.:.................................300/2797 kg/h Burner capacity on fuel oil, min./max.:....................................300/2936 kg/h Colour of burner................................................................................standard
9 Data for water level operation
Too high water level alarm:.............................................................+165 mm
High water level warning:...............................................................+135 mm Normal water level:...............................................................................0 mm Start stand-by feed water pump:....................................kg/cm2/not AI supply Low water level warning:.................................................................-145 mm Too low water level alarm and burner off:.......................................-190 mm Too low water level alarm and burner off:.......................................-190 mm
Language for manuals:..............................................................................UK
Set of instruction manuals:....................................................................5/ship Document revision date:............................................................07 JAN 2004