DIAPHRAGM PUMP

MANUAL BOOK

Diaphragm Pump
P700 Series
MAXPUMP P700 Series
Manual Book

Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
OPERATOR’S MANUAL P700X-XXXX5-EF
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

2” AIR OPERATED DOUBLE DIAPHRAGM PUMP


1:1 RATIO

PUMP MODEL AND MATERIAL CODE

P 700 X - XX X X X X - XX

MODEL CASING DIAPHRAGM BALL VALVE VALVE SEAT GASKET CONNECTIONS PORTS
P7=1/4" P=Polypropylene T=Teflon T=Teflon T = Teflon T=Teflon 1 = BSP AB = STAND-
ARD
P18=3/8" K=PVDF M=Santoprene M=Santoprene M = Santoprene M=Santoprene 2 = FLANGE
EF = CENTRE
P65=1/2" O=POM H=Hytrel H=Hytrel H = Hytrel H=Hytrel 5 = NPT
P100=3/4" A=Aluminium V=Viton V=Viton V = Viton V=Viton
P160=1" SE=SS304 N=Buna-N N=Buna-N N = Buna-N N=Buna-N
P500=1.5" S=SS316 D=EPDM D=EPDM D = EPDM D=EPDM
P700=2" C=Cast iron G=Geolast SE=SS304 SE = SS304 SE=SS304
P1000=3" PU=Polyurethane S=SS316 S = SS316 S=SS316
P = Polypropylene

PUMP DATA
Models : P700 Series
Technical Parameters
Suction lift (mwc) Dry ………………… 5
Wet ………………. 8
Max particle diameter(mm) ……. ….6
Suction and discharge size(in) …….. 2
Air inlet Size(in) …………….……………. 1/2
Max flow Rate (l/min) ….…………….. 587
Max head(m) …………………………..…. 84
Max air inlet pressure(bar) …………. 8.4

Material Composition
Casing: PP, PVDF Aluminum, Cast iron
Diaphragm: Santoprene, Hytrel, Teflon,
Viton, EPDM, Buna-N
Ball: Santoprene, Hytrel, Teflon, Viton,
Stainless steel, Ceramic
Ball seat: Santoprene, Hytrel, Teflon, Vi-
ton, Stainless steel, PP
Center block: PP, Aluminum
Weight
P700A (Aluminum pump): 27kg
P700C (Cast iron pump): 78kg
P700P (PP pump): 25kg
P700K (PVDF pump): 34kg
P700SE (SS304 pump): 48kg
P700S (SS316 pump): 48kg

Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
Operating Principle

After connecting the compressed air, air valve control the compressed
air impels diaphragm 1 moves toward right, meanwhile, the diaphragm
1 also extrude medium and cause it out of chamber. Diaphragm not only
convey medium, also isolate compressed air and medium in the pump
chamber. When one diaphragm is pushed away from the center body,
another diaphragm will moves toward center body for these two dia-
phragm are connected by one rod. When diaphragm 2 moves toward
center body, the following high pressure compressed air will be dis-
charged out through the muffler, meanwhile, the pump inlet side will
creates a vacuum, then atmospheric pressure will push the medium into
suction pipeline. The pump entry valve ball will be raised and leaves the
valve seat, the medium will enter into pump chamber.

When the diaphragm 1 under high pressure, will slowly move to maxi-
mum position of stroke. Meanwhile, the compressed air will slowly enter
into diaphragm 2 following space and impels the diaphragm 2 away the
center body. The diaphragm 1 also will moves toward center body for
these two diaphragms are connected by one rod. The diaphragm 2 will
extrude the medium and function on entry valve ball and seal up the suc-
tion pipeline through the water power. The water power also will func-
tion on exit valve ball and open the discharge pipeline. Meanwhile, exit
valve ball of pump another side will shut down for pressure function, en-
try valve ball will open, then the medium will enter into the pump cham-
ber.

When one stroke finish. The compressed air will enter into diaphragm 1
following space again through reversing valve, simultaneously the dia-
phragm 2 following compressed air will discharge out through muffler.

Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
GENERAL GUIDELINE

INSTALLATION AND START-UP AIR LINE MOISTURE


Locate the pump as close to the product be- Water in the compressed air supply can create
ing pumped as possible. Keep the suction problems such as icing or freezing of the ex-
line length and number of fittings to a mini- haust air, causing the pump to cycle erratically
mum. Don’t reduce the suction line diame- or stop operating. Water in the air supply can
ter. be reduced by use a point-of-use air dryer to
supplement the user’s air drying equipment.
For installations of rigid piping, short sec-
This device removes water from the com-
tions of flexible hose should be installed be-
pressed air supply and alleviates the icing or
tween the pump and piping. The flexible
freezing problems.
hose reduces vibration and strain to the
pumping system.
AIR INLET AND PRIMING
AIR SUPPLY To start the pump, open the air valve approxi-
mately 1/2” to 3/4” turn. After the pump
Air supply pressure cannot exceed 125 psi
primes, the air valve can be opened to increase
(8.6bar). Connect the pump air inlet to an air
air flow as desired. If opening the valve in-
supply of sufficient capacity and pressure
creases cycling rate, but does not increase the
required for desired performance.
rate of flow, cavitation has occurred. The valve
When the air supply line is solid piping, use a should be closed slightly to obtain the most
short length of flexible hose between the efficient air flow to pump flow ratio.
pump and the piping to reduce strain to the
piping. The weight of the air supply line, reg-
ulators and filters must be support by some BETWEEN USES
means other than the air inlet cap. Failure to When the pump is used for materials that tend
provide support for the piping may result in to settle out or solidify when not in motion, the
damage to the pump. A pressure regulating pump should be flushed after each use to pre-
valve should be installed to insure air supply vent damage (product remaining in the pump
pressure does not exceed recommended lim- between uses could dry out or settle out. This
its. could cause problems with the diaphragms and
check valves at restart) in freezing tempera-
tures the pump must be completely drained
AIR VALVE LUBRICATION
between uses in all cases.
The air distribution valve and the pilot valve
are designed to operate without lubrication.
This is the preferred mode of operation. STORAGE
There may be instances of personal prefer- If the equipment is to be stored prior to instal-
ence or poor quality air supplies when lubri- lation, place it in a clean location. The pump
cation of the compressed air supply is re- should be stored in an ambient temperature of
quired. The pump air system will operate 15°C (59°F) to 25°C (77°F) and relative humidi-
with properly lubricated compressed air sup- ty below 65%. It should not be exposed to any
ply. Proper lubrication requires the use of an heat source e.g. radiator, sun as this could re-
air line lubricator set to deliver one drop of sult in a negative way on the tightness of the
SAE 10 non-detergent oil for every 20 SCFM pump. Do not remove the protective covers
(9.4liters/sec) of air the pump consumes at from the suction, discharge and air connec-
the point of operation. Consult the pump’s tions which have been fastened to keep pump
published performance curve to determine internals free of debris. Clean the pump thor-
this. oughly before installation.
Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
TYPICAL INSTALLATION GUIDE

IMPORTANT SAFETY INFORMATION

Bumi Prima Century Sdn Bhd— EykaPump MAXPUMP Series P700. www.eykapump.com
OPERATING TEMPERATURE LIMITATION

Diaphragm Material Maximum Minimum


Viton: excellent corrosion resistance, resistance to various acids
(including the median concentration of oxidizing acid),alkali, salt, petrole- 350℉ 176.6℃ -40℉ -40℃
um products, hydrocarbons, etc.
PTFE(Teflon): excellent corrosion resistance, almost resistant to all chem-
ical media (including concentrated nitric acid and aqua regia). Except
350℉ 176.6℃ 40℉ 4.4℃
melting of lithium, potassium, sodium, chlorine trifluoride, high-
temperature oxygen trifluoride, sulfur-speed liquid fluorine.
Santoprene: good abrasion resistance, chemical resistance and heat
resistance, suitable for general acid and alkali, not suitable solvent. Can 220℉ 104.4℃ -20℉ -28.9℃
replace the EPDM/EPR material.
Hytrel: good abrasion resistance, used in most of the neutral fluid. Can
220℉ 104.4℃ -20℉ -28.9℃
replace Buna-N materials.
EPDM: abrasion resistance, aging resistance, ozone resistance , suitable
250℉ 121.6℃ -40℉ 40℃
for general acid and alkali.
Buna-N: widely used in gasoline and other oil products. Suitable for use
212℉ 100℃ -40℉ 40℃
at room temperature.
GE: better abrasion resistance than Hytrel, the same chemical resistance
220℉ 104.4℃ -20℉ -28.9℃
as Buna-N.
Pump body material
PP: Medium abrasion resistance, good chemical resistance, good versa-
150℉ 65.5℃ 40℉ 4.4℃
tility, especially for common acid-base.
POM: good solvent resistance, abrasion resistance. Low friction, low
150℉ 65.5℃ 40℉ 4.4℃
moisture absorption.
PVDF: strong chemical resistance, crush resistance, abrasion resistance.
200℉ 93.3℃ 40℉ 4.4℃
good corrosion resistance for acid, alkali and variety of organic solvents.

Note: The maximum and minimum temperature is the limited operating temperature of these materials.
Temperature and pressure will affect the diaphragm life. Operating under the maximum or minimum tem-
perature, will not achieve maximum life.
GROUNDING THE PUMP