Download as pdf
Download as pdf
You are on page 1of 2
NATIONAL INSTITUTE OF TECHNOLOGY, KURUKSHETRA, Roll No. Month and Year of the Examination: Dee, 2020 Progsamme: B.Tech, 3” Semester Subject Design of Stee! Strcturest CourseNo CEPC-2S... ‘ Maximum Marks Number of Questions to be Attempted 4 oso. Timeallowed scanning and uploading. Total No. of Questions 5.. Total No. of Pages used 2... Une stad cari, te ymDela hay tial meanings a coven wd he Sec. Assume suitably and state additional data required, if any. -Use of 1S:800-2007 and Steel Table is Allowed Uploading of Answer Sheet after specified time limit will not be considered. Page No. and Roll No. should be marked on each and every page of answer sheet with signature -Maximum sheet used is 30 and should be marked like 1/30, 2/30, 3/30 and so on ‘Note: Questions No.1 is compulsory. Attempt any three from the rest. 1a. Design a double cover plate but joint using M24 bolts of 5.6 grade to connect two flats of size 350mm x16 mm for maximum efficiency. Assume that one shear plane intercepts the threads of the bolts. The yield and ultimate tensile strength of the flats are 250 MPa and 410 MPa, respectively. 50. : 2 Hours for Answering and 20 minutes for 7 bb, Determine the size and effective length of the side fillets shown in Fig. 1, to connect two plates with cross section of 150x10mm and 100x10 mm which are subjected to tension of 125 kN at working load. The ultimate strength of plates fu is 410MPa, 7 a oe ISt oom a - Fig.-l 2. Determine the safe load *P'that can be carried by the joint shown in Fig.2. The bolts used are M20 of grade 4.6, The thickness of flange of I-section is 9.1 mm and that of bracket plate 10mm. 12 OR Design a connection to connect a 12 mm thick bracket with the flange of column ISHB200 as shown in Fig.3, using M20 bolts of grade 4.6 to carry a factored vertical load of 200kN acting at 300 mm from the face of column. The grade of steel is E250. Sheet No. 2 200 kN 300mm, Fig3 Design a built-up column consisting of two channels placed back to back connected with battens having effective length 5.85 m carrying factored axial load of 2000KN. Also Design battens and its connection. Use steel grade Fe410 and bolts of grade 4.6. 12 Determine the ultimate shear and moment capacities of the section shown in Fig. 4. In addi the end posts, intermediate transverse stiffeners are provided at a spacing of 3m. Ke S0@ orm ——y If Som n . J oc mm fs. 4, Design the section of a plate girder 28m in span to carry a uniform load of 40 kN/m throughout the span due to dead and live load. Also design Intermediate transverse web stiffener. 2 , Define various limit states. Explain any one in details.

You might also like