C60 - C70 Regi Loop Adjustment NVMs

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Xerox Color C60/C70 Buckle / Loop Adjustment NVMs

Chain Link Description


Regi Loop amount Adjustment
(Pre Registration Stop Timing)
(MSI Path / 64-79gsm)
742 394

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 80-90gsm)
742 395

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 91-105gsm)
742 396

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 106-128gsm)
742 397

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 129-150gsm)
742 398

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 151-176gsm)
742 399

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 176-220gsm)
742 400
Regi Loop amount Adjustment
(Pre Registration Stop Timing)
(MSI Path / 221-256gsm)
742 401

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 257-300gsm)
742 402

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / OHP,TackFiim)
742 403

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(MSI Path / 封筒)
742 404

742 405 Spare


Regi Loop amount Adjustment
(Pre Registration Stop Timing)
(TA Path / 64-79gsm)
742 406

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(TA Path / 80-90gsm)
742 407

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(TA Path / 91-105gsm)
742 408

Regi Loop amount Adjustment


(Pre Registration Stop Timing)

742 409
(TA Path / 106-128gsm)
742 409

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(TA Path / 129-150gsm)
742 410

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(TA Path / 151-176gsm)
742 411

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(TA Path / 177-220gsm)
742 412

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(TA Path / 221-256gsm)
742 413

Spare
Regi Loop amount Adjustment
(Pre Registration Stop Timing)
742 414
(TA Path / 257-300gsm)

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
(TA Path / OHP,TackFiim)
742 415

Spare
Regi Loop amount Adjustment
(Pre Registration Stop Timing)
742 416
(TA Path /Envelope)
742 416

742 417 Spare


Regi Loop amount Adjustment
(Pre Registration Stop Timing)
742 418 (Dup Path / 64-79gsm)

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
742 419 (Dup Path / 80-90gsm)

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
742 420 (Dup Path / 91-105gsm)

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
742 421 (Dup Path / 106-128gsm)

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
742 422 (Dup Path / 129-150gsm)

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
742 423 (Dup Path / 151-176gsm)

Regi Loop amount Adjustment


(Pre Registration Stop Timing)
742 424 (Dup Path / 177-220gsm)
erox Color C60/C70 Buckle / Loop Adjustment NVMs
Details Default Min Max
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path / 64-79gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
40 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path / 80-90gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
40 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path / 91-105gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
40 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /106-128gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /129-150gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /151-176gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /177-220gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /221-256gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /257-300gsm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /OHP, TackFilm)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(MSI Path /Envelope)
MSI Path = IOT-MSI, HCF3, HCF-MSI
30 0 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 71ms
30 10 50
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /64-79gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /80-90gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /91-105gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /106-128gsm)

30 10 50
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /129-150gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /151-176gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /177-220gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /221-256gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /257-300gsm)
MSI Path =Tray1-4, HCF1
30 10 50

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /OHP, TackFilm)
MSI Path =Tray1-4, HCF1
30 10 60

1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(TA Path /Envelope)
MSI Path =Tray1-4, HCF1
30 10 60

1Count = 1ms
30 10 60

Adjustable in the range of +/-30ms as 30 = 85ms


30 0 60
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(DUP Path /64-79gsm)
30 0 60
1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(DUP Path /80-90gsm)
30 0 60
1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(DUP Path /91-105gsm)
30 0 60
1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(DUP Path /106-128gsm)
30 0 60
1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(DUP Path /129-150gsm)
30 0 60
1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(DUP Path /151-176gsm)
30 0 60
1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms
Adjusts Regi Loop amount (Pre Registration Stop Timing)
(DUP Path /177-220gsm)
30 0 60
1Count = 1ms
Adjustable in the range of +/-30ms as 30 = 85ms