Manual Instalacion Securope en Chapa Grafada
Manual Instalacion Securope en Chapa Grafada
Securope
On standing seam roof
DOC028-UK-17.08.10
DOC027-UK-17.08.10
Table of content
1. Homologation ................................................................................................................................................................................................. 3
2. Fixing assembly on standing seam roof ............................................................................................................................................... 3
2.1. Introduction .......................................................................................................................................................................................... 3
2.2. Rigging the anchor........................................................................................................................................................................... 5
2.3. The cross members .......................................................................................................................................................................... 7
2.4. The clamp S-5..................................................................................................................................................................................... 7
2.4.1. Fixing assembly with clamps V-S5-Z on Kalzip pannels ...............................................................................................8
2.4.1. Fixing assembly with clamps V-S5-E on double folded standing seam ............................................................... 10
2.4.2. Other types of clamps available for double folded standing seam ........................................................................ 12
2.5. Switch................................................................................................................................................................................................... 14
2.6. Photos taken on site....................................................................................................................................................................... 15
2
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
1. Homologation
The anchoring device Securope has been tested and approved by Apave according to standards EN
795:2012 type C and CEN/TS16415:2013, CE type test certification number 0082/1084/160/04/0116
Fallprotec has designed fasteners to allow the fixing of Securope life line on fragile structure like
standing seam roof.
3
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
The force applying on end anchors should be below 12 Kn in the event that the Securope is installed
on standing seam roof. To fulfil this requirement it is necessary to limit the number of users attached
on the line, to reduce the span between two anchors and to install an energy absorber on one end
anchor.
As an example table 2 gives the parameters of a life line installed on a standing seam roof, the length
ranging from 5 to 100 m.
Length of the line Span between anchors Type of absorber Number of users
meter Max. meter Max.
5 5 LDV032 2
10 5 LDV032 2
15 5 LDV032 2
20 6.7 LDV032 2
25 8.4 LDV032 2
30 10 LDV032 2
40 10 LDV032 3
50 10 LDV032 3
60 12 LDV032 3
70 12 LDV032 3
100 12 LDV032 4
Standing seam roofs represent the state of the art in roofing today, offering service life and
dependability measured in decades. Attachment of rooftop ancillary items, however, has been
difficult and often the source of leaks and maintenance problems. Securope fixing assembly to attach
life line on standing seam roof, without piercing the panel, does not jeopardise the integrity of the
roof.
Standing seam roof consists of a corrugated metal sheet, fixed on purlins. The corrugated metal
sheet varies according to manufacturers, in dimensions and material.
4
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
Fig. 2 Rigging end anchor fitted with energy absorber on standing seam roof
5
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
Fig. 4 Rigging end anchor fitted with line tensioner on standing seam roof
6
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
7
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
Fig. 7 V-S5-Z-Clamp
8
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
The Z Clamp will fit profiles that have a “bulb” shaped seam configuration. The clamp is designed to
be easily installed anywhere along the length of the panel seam.
The Z clamp is a structural aluminium clamp, compatible with aluminium, zinc plated and stainless
steel panel. It has been tested for load failure results on Corus and Bemo panels. The failure mode of
this clamp is migration of 8 mm.
9
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
LDV020 : 30-50
cm
10
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
The E clamp is designed especially for the traditional double folded standing seam profile that is
popular all over Western Europe. The clamp is furnished, complete with M 10 Stainless steel bolts,
washer, set screws and with screw gun bit tips included in every box. Mounting holes are laterally
located over the canter of the seam and 13 mm from each end of the clamp.
11
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
The S-5-U clamp is used on double folded standing seam having a height below 20.8 mm and a
width below 10.5 mm.
The S-5-T clamp is used on double folded standing seam, the top of the seam being bended with an
angle of 90° ( ┐).
12
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
The S-5 B clamp is used on double folded standing seam, plate being in brass.
NOTE:
All load incurred by the clamp will be transferred to the panel seam. Panel attachment and structural characteristics must
be adequate to withstand such loads. Clamps have been laboratory tested on various seam types, profiles and materials
for ultimate tensile failure loads parallel to panel seam, see tables above.
For end anchors the maximum load shall not exceed 12 KN and for intermediate anchor, it will not exceed 6 KN, a safety
factor of 2 should be used.
The Securope life line parameters (length of cable, span between anchors and number of users) will be chosen to limit
the force imposed on the end anchors to 12 KN max. The force imposed on the intermediate anchor is 6 KN. In general, 4
clamps per fixing assembly are enough, a safety coefficient of 2 should be considered for the calculation of the quantity
of clamps on the fixing assembly. If any doubt, send the parameters of your project to Fallprotec S.
13
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
2.5. Switch
Fallprotec has designed a switch for Securope lifeline. There can be four branches (the intersection
of two lines) Fig. 52 or 3 branches (intersection of three lines) Fig. 53. The switch manufactured in
stainless steel, has a base on which are placed 4 fixed anchors. A anchor, located in the center
allows 360 ° rotation for the glider to change direction. A safety disc mounted on springs, prevents
the glider to escape from the line when changing direction.
The rigging on standing seam roof requires two specific cross plates shown Fig. 58
14
Installer Manual
Securope on standing seam roof
DOC027-UK-17.08.10
15