Mitsubishi Basic Kit

M/R Types Of Control:

PRODUCT NAME CONTROL TYPE CODE


VFDL GPS
VFDLA GPS-2
GPS-3
VFEL GPW-3
GPX
GPS-4 (1st Version)
NEXWAY-S VFGL GPS-4 (2nd Version)
GPS-5
NEXIEZ VFGLC GPS-X (1st Version)
GPS - X (2nd Version)
GPS-XL2
LATINO VFGLC2 GPS-LATINO
MRL Types Of Control:

PRODUCT NAME CONTROL TYPE CODE

VFFL GPQ
ELENESSA GPQ2
VFGL GPQ3
GPQ4 (1st Version)
VFGLC GPQ4 (2nd Version)
GPQ-4 (3rd Version)
NEXIEZ MRL VFGLC2 GQX
Remote Control:
START : 81
Default Installation Password: 1730
Customer Default Password: 7777
Change Password : 82 ( Customer Password should be changed with in a limit
4000 to 9999)
COP Access: 73
Hall Access: 78
Important LEDS:
# 5 = "5" Contactor Status
29 = Safety Circuit
41 DG = Door Gate
DZ = Door Zone
420 = 48 DCV
60 = Auto Signal
Important LEDS in Car Top station:
OLT/CLT = Open Limit /Close Limit
GOFF = Gate Off
DOQ = Door Open Queue
WDT = Watch Dog Timer
#21 = Door Open
#22 = Door Close
Important Contactors:
#5 = without picking up of this contactor, elevator will not move even in Slow
speed operation.
#M5 = Contactor related to MELD (ARD)
#LB = Contactor related to BRAKE
Important Breakers:
HST - Hall station
CST- Car station
ELD,CLD - Emergency Landing Device
SCB , LIGHT - Lighting Supply
MCB- Main Circuit Breaker
CP- Control Power
ACB- Grouping Power
PL - Pit Light
CLASSIFICATION OF ERRORS: (MON1 - 1 OR 5, MON 0 - 0 ^F)
 NFS - Near Floor Stop
Slow Down, SDE, OLT/CLT, OVLD. Etc..
 NRS - Not able to ReStart
Drive, OVLD, Phase Malfunction, Etc..
 DOOR - Door Related
 H/W- Hoist way Including Inverter, Power Source
 SEQ - SEQUENCE (Contactors, Running direction, Call Allocation Etc..)
 SPEED - Abnormal slow/high speed, encoder related, Etc..
 E-STOP - 29 Safety Circuit.
 BRAKE - Brake Related including #LB
 Transmission - Transmission Between Car top and Control
 Supervision - Group Control and Grouping Call Allocation
Important Tunings:
 Inspection Mode: SET 1 - 0, SET 0 - 6
 FMS: SET 1 - 0, SET 0 - 7
 OVL Buzzer: SET 1- 0, SET 0 - C
 Magnetic Pole Data Written: SET 1 - 0, SET 0 - D
 To Check TSD Margin In VFGH : SET 1 - 0, SET 0 - E
 To Check TSD Running In VFGH: SET 1 -0, SET 0 - F
 Auto Mode: SET 1 - 0, SET 0 - 8
 NL Write: SET 1 - 0, SET 0 - 2
 NL Value Check: SET 1 - 7, SET 0 - 2
 BL Write: SET 1 - 0, SET 0 - 3
 BL Value Check: SET 1 - 7, SET 0 - 3
 FL Write: SET 1 - 4, SET 0 - 0^8
 FL Value Check: SET 1 - 7, SET 0 - 4
 NL Write for Maintenance: SET 1 - 0, SET 0 - 5
 Over Load Bye Pass: SET 1 - 4, SET 0 - 0 ( If u done this over load data
will get erased NEED TO BACKUP BEFORE BYE PASS)
 Balancing Car: SET 1 - 0, SET 0 - 0
 SWT Parameter Version Check: MON 1 - F, MON 0 - 7
Points to Remember for Door Issues:
 Door slowly closing/opening
can adjust by jumper setting in car top station (accerlation/deaccerlation),
OLT/CLT Adjustment.
 Door Fastly Closing/Opening
can adjust by jumper setting in car top station (accerlation/deaccerlation), OLT/CLT
Adjustment.
 Door Fastly closing & Reduce speed later
can adjust OLT/CLT, as well as through jumper setting in car top station.
 Door Half close and again opening , this repeats
Door load sensor can adjust by jumper setting in car top station.
Single Beam/ Multi Beam Photo Electric Sensor should be checked
 Door Closing with vibration:
Car door Motor encoder has to check and door motor belt tension has to
check.
 No Movement in Door Motor.
Door Motor Voltage has to check
Door motor can be easily identify as defective by checking all three phase's
ohm value (ohm value of all three phase should be equal for good door motor)
 Single Beam/ Multi Beam Photo Electric Sensor wires has to be connected
with correct polarity.
 OLT/CLT pins were look similar so care full in inserting in car top pcb.
 Door Open / Close button has to cross check with #21,#22 Signals
if door operation is in reverse motor revolution direction has to readjust by
jumper setting in car top.
OIL / GREASE FOR OLD TYPES
Buffer Oil = #3, #4
Rope Oil = #6
Grease = #5
Gear Oil = #51
Rail Oil = #52
GREASE For Latest Nexiez Type:
For Internal Brake MRL(PMF-MELINA) Elevator = #25 Grease (220 gm)
For External Brake MRL (PM-AMEC) Elevator = #5 Grease (220 gm)
Basic Trouble shooting Procedures:
 Check the following Conditions of the troubled elevator.
a)Elevator Cabin is in which Floor.
b) Check for any human Entrapment is there if yes means, first of all communicate
with the person entrapped, give him confidence that you are elevator expert and will
rescue very soon. immediately proceed rescue process.
b) Elevator Cabin is in Floor level? if not how much difference
c) All Indicators are working fine (lighting or not) including Hall Button, COP, Hall
Lantern
d) Leds in Control Panel / incase of MRL Elevators Safety Leds in Hall Inspection
Panel are fine?
e) Door Condition ( whether door is not opening/closing or door is repeatedly open
/close. (or) door is producing abnormal vibration/ jerk etc.
f) Check Error Code in control panel ( Both current and latch Errors)
g) Measure rated voltages as required (Based on Error List)
h) Never try to reset control until note down all error codes including latch error
details.
Tips to solve Floor Vicinity Issues:
Case 1:

FLOOR UP DOWN

4 +4 MM N/A
3 +4 MM +4 MM

2 +4 MM +4 MM
1 N/A +4 MM
Only should adjust pad switch
Case 2:
FLOOR UP DOWN

4 +4 MM N/A
3 +4 MM - 4 MM

2 +4 MM - 4 MM
1 N/A - 4 MM
Adjust PTSH (Pattern Shift) SET1 = 1, SET0 = ?
Case 3:
FLOOR UP DOWN
4 0 MM N/A
3 0 MM -4 MM

2 0 MM -4 MM
1 N/A -4 MM
Adjust DNSH (Down Shift) SET1 = 2, SET 0 = ?
Case 4:
FLOOR UP DOWN
4 0 MM N/A
3 +2 MM +2 MM
2 - 3 MM -3 MM
1 N/A -1 MM
Adjust PAD PLATE or FSHIFTSET1 = 5, SET 0 = ?

DNSH & FSHIFT will not Applicable in Re level Option Enabled Elevators.
Contactor checking mock up format:
CFLBB - LB OFF FAILURE
LB Relay is picking up or not No
LB Coil Circuit has Problem
Yes
Coil is OK? Yes
Check Coil Voltage is Ok or
Yes Not
Check Contact Condition
(RLB)
LB Coil Failure
Yes
Check Voltage in R1 PCB

Yes Check Contact


resistance Wiring
Condition

Check Circuit of DLB

Check Circuit
48 V Ok?
of RLB

Bad Contact Cut


No Wiring

Check
Contact
Resistance
R1 PCB Failure Wiring
Condition

COP Power Source Details:


Pin No Name of Connector
C1 SP
1 620 (Power Supply For Serial Positive side of speaker out put
Transmission)
2 600 (GND serial transmission) Negative side of speaker out put
3 DO (C/P to AAN)
4 Di (AAN to C/P)
5 601 (GND power supply)
6 621 (12V power supply)
In Latest Controls like Nexiez following tunings will Display The Installation
Position Error of slow down switch.
SET 1/0 =7/4
OR
MON1/0 =3/B

Nexiez Load Value Check Procedure


MON 1 = 0 , MON 0 = D
SW2 (Middle) = (Current Load In Car)
SW2 = (No Load Value)
SW2 = (Balance Load Value)
IMPORTANT PCBS

P1 -PCB - Processor
R1 - PCB - Communication B/W apparatus and Processor
M1 - PCB - MELD (ARD)
E1,E2,E3 - PCB - Inverter
Z1 PCB - Additional Features
DOR PCBS - Car Top Control
INTERCOM DETAILS: 24 Volt