Professional Documents
Culture Documents
BL-1300 Series: Instruction Manual
BL-1300 Series: Instruction Manual
source.
*96M12900-1* Model BL-1300, 1301, 1300HA, 1301HA, 1350HA, 1351HA, 1370, 1371
Wavelength 660 nm
Output 85 W
Laser Bar Code Reader Pulse duration 112 s
BL-1300 Series
FDA (CDRH)
Class 2 Laser Product
Laser Class Part 1040.10
IEC 60825-1 Class 2 Laser Product
WARNING Failure to follow these instructions may lead to injury. The BL-1300 Series barcode readers are equipped with the following
safety measures.
Failure to follow these instructions may lead to product • Laser radiation emission warning LED (LASER LED)
CAUTION damage (product malfunction, etc.). During laser emission, the LASER ON LED illuminates. The LED ON
status can be clearly visible through protective eyewear; specifically
Provides additional information on proper operation.
designed for the wavelength of 660nm.
Note
Safety precautions on laser product Use the suitable IEC warning/explanatory label included in the package
of this product according to the countries and/or regions where this
product is used.
Use of controls or adjustments or performance of
procedures other than those specified herein may result In this case, it can be affixed on the IEC warning/explanatory label,
WARNING
in hazardous radiation exposure. which has already been affixed to this product.
1 E BL-1300-IM
For proper use of this product Canada IC (Industry Canada) regulations
The BL-1300 Series conforms to the following IC EMI regulations.
Precautions on use
• ICES-003, Class B digital apparatus
• The BL-1300 uses a 5 V DC power supply. Using a
different voltage level may damage the unit. When using
the KEYENCE power supply unit N-R2, N-R4, N-UB, N-L1, CE marking
NX-50 Series or DV-90 Series, select the voltage level The BL-1300 Series complies with the following essential requirements
which can be supplied by the power supply unit. If a of the EU Directives.
nonconforming power supply is connected, the BL-1300 • EMC Directives (2004/108/EC)
may be damaged. • Low-voltage Directives (2006/95/EC)
• Before connecting or disconnecting the cable, be sure
The following harmonized standards are applied to these products in
to turn off any device connected to the BL-1300 Series.
Otherwise, the BL-1300 Series may be damaged. order to confirm the compliance.
• Applicable standards (EMI) EN55011, Class A
• Do not disassemble or modify the BL-1300 Series, as
EN55022, Class B
this may cause product failure.
• Applicable standards (EMS) EN61000-6-2
• Locate cables as far as possible from high-voltage EN61000-6-1
lines and power lines. Otherwise, generated noise may
cause product failure or malfunctions. * The length of the communication and power cables should be less than 30
m.
• Before mounting the BL-1300 Series, insulate the
mounting location. Otherwise, generated noise may cause
product failure or malfunctions.
Package Contents List
• The BL-1300 is a
precision instrument.
Dropping the unit or Main unit
subjecting it to shock BL-1300/1301/1300HA/ BL-1350HA/1351HA
may cause damage. Be 1301HA/1370/1371
careful when
unpacking, carrying, an
mounting it. Do not
CAUTION
hold the units by their
cables.
• Do not hold the units by
their cables when carrying
them. The units may hit
each other and become Mounting bracket
damaged. BL-1300/1301/1300HA/ BL-1350HA/1351HA
1301HA/1370/1371
Mounting bracket A and B: 1 each Mounting bracket: 1
BL-1300 Series
FDA (CDRH)
Class 2 Laser Product
Washer: 4 WARNING
where other people unconnected with the laser work
might be present.
• Be careful of the path of the laser beam.
If there is a danger that the operator may be
exposed to the laser beam reflected by specular or
diffuse reflection, block the beam by installing an
for repairs.
WARNING Failure to follow these instructions may lead to injury. The BL-1300 Series barcode readers are equipped with the following
safety measures.
Failure to follow these instructions may lead to product • Laser radiation emission warning LED (LASER LED)
CAUTION damage (product malfunction, etc.). During laser emission, the LASER ON LED illuminates. The LED ON
status can be clearly visible through protective eyewear; specifically
Provides additional information on proper operation.
designed for the wavelength of 660nm.
Note
• The BL-1300 Series is dropped or the housing is Mounting screw (M3): 2 General precautions
• Do not use this product for the purpose to protect a human body or
part of a human body.
• This product is not intended for use as an explosion-proof product. Do
not use this product in a hazardous location and/or potentially
IEC warning/explanatory label locations
BL- 1300/1301/1300HA/
1301HA/1370/1371
BL-1350HA/1351HA
explosive atmosphere.
damaged. •
•
We recommend that you take substantial safety measures to avoid
any damage in the event a problem occurs.
If the BL-1300 is modified or used in any way other than described in
the specifications, its function and performance cannot be guaranteed.
When the BL-1300 is used in combination with other instruments, the
function and performance may be effected by operating conditions and
the surrounding environment.
Safety precautions on laser product Use the suitable IEC warning/explanatory label included in the package
smell WARNING
Use of controls or adjustments or performance of
procedures other than those specified herein may result
in hazardous radiation exposure.
of this product according to the countries and/or regions where this
product is used.
In this case, it can be affixed on the IEC warning/explanatory label,
which has already been affixed to this product.
FCC regulations
The BL-1300 Series complies with the following FCC EMI regulations.
• FCC Part 15 Subpart B, Class B digital devices
E BL-1300-IM 2
Part Names and Functions Connecting the power supply
Connect a cable with a
length of 4.8 m or less.
6. Transmitter/receiver 6. Transmitter/receiver
+5V 11 +
8. Cable 8. Cable 5 VDC
GND 12
Internal circuit
4.7 kΩ
10 kΩ 100 Ω
• When NG output is ON: The orange LED TIM
Contact
2 OK/NG/ERR LED 6,10
lights.
or
• When ERR output is ON: The red LED
lights.
non-contact
12
GND
3 TIMING LED Lit when trigger input is ON.
Displays the reading stability and the BL- 5 VDC
4 STABILTY LED
1300 operating status.
This switch is used to perform the following
operations.
• If this switch is pressed once shortly, a
Wiring OUT1/OUT2/OUT3/OUT4 output pins
barcode is read once. • OUT1 (OK) is used as output indicating that reading is successfully
• Starting and canceling the test mode completed and that the comparison and matching with preset data is
5 TEST SWITCH • Start reading of batch set bar codes judged as OK.
• Registering preset data
• Canceling PLC link errors • OUT2 (NG/ERROR) is used as output indicating that reading has
• Fixing the communication setting to the failed and that the comparison and matching with preset data is judged
initial value when setting transmission and as NG.
reception
• OUT3 (ERROR) is used as output indicating that reading has failed.
Receives the emitted and reflected light of • OUT4(BUSY) is output any time the trigger input cannot be accepted,
6 Transmitter/receiver
laser beams and reads barcodes.
such as cases where the BL-1300 Series is at initial start-up or in
7 Connector Used to connect to the communication unit.
setting mode, the motor/laser is damaged, the motor/laser is locked, or
8 Cable Cable length is 2 m.
the number of rotations of the motor is changed.
The output form of each signal is NPN open collector.
Connection and Wiring Method
Connection connector pin layout
Internal circuit
3.3 kΩ OK/NG
1, 2, Load
33 V 5, 9
1 2 6.8 kΩ
Cable head cross-section view 12
3 4 5 6 RP17-13PA-12PC plug (male) GND +
7 8 9 10
Manufactured by Hirose Electric Co., Ltd.
11 12
3 E BL-1300-IM
Installing the BL-1300 Series
2 Fasten the mounting bracket to the unit.
When installing the BL-1300 Series, adjust the mounting angle and
distance as shown below. * Mounting screws (M4) are not included.
Adjusting the mounting angle When mounting bracket A is used When mounting bracket B is
Mount the BL-1300 Series so that a laser beam is applied at an angle of used
approximately 15. Mounting
Mounting screw
For the front type of the BL-1300 Series BL-1300/1301/1300HA/1301HA/ (M4) screw (M4)
1370/1371, the unit must be tilted at an angle of 15. Washer
For the side type BL-1350HA/1351HA, it is not necessary to tilt the unit Washer Insulating
because a laser beam is emitted at an angle of 15. Insulating spacer
spacer
Front type Side type
BL-1300/1301/1300HA/ BL-1350HA/1351HA
1301HA/1370/1371
Reading distance
Reading distance
15 15
Incorrect Incorrect
Laser
• The reading distance and angle may vary depending beam
on the narrow bar width, size, and printing quality of
bar codes. Be sure to test the BL-1300 Series' ability to Mounting Mounting
read the actual bar codes using "Reading rate check bracket bracket
mode". Supplied mounting Supplied mounting
screw (M3) screw (M3)
Mounting
bracket A
Laser
beam
Mounting
bracket B
Be sure to mount the supplied spacer to suppress the
Laser influences of noise. A reading error or an incorrect error
beam Note reading may occur if the insulation spacer is not
Supplied mounted.
Supplied mounting mounting
screw (M3) screw (M3)
E BL-1300-IM 4
Mounting the BL-1300 Series without the mounting Mounting bracket
bracket * On the bottom of the mounting bracket, an insulation sheet is attached.
Do not remove it.
1 Fasten the BL-1300 Series. • For the front type
Fasten the BL-1300 Series in the mounting position with M3 screws.
Mounting bracket A Laser
* The M3 screws are not included. Select the M3 screws after checking beam
the panel thickness and other factors of the mounting position.
(The mounting hole for the BL-1300 Series is 4 mm deep.)
15°
7.82
BL-1300/1301/1300HA/ BL-1350HA/1351HA
1301HA/1370/1371
59.6
43.35
5.5
38.65
5°
R19
10°
2.2
19.6
14
9
Mounting Mounting 2-R 2.75 3 5.5 2-R 2.75
hole hole 25
37.6
Mounting screw (M3) Mounting screw (M3)
6
Dimensions
5.3
Main unit (BL-1300/1301/1300HA/1301HA/1370/1371)
26.5
40
29.75
3
29.33
Laser beam
Laser beam
2-R 2.65 5.3
15.95
15°
43.58
31
28.01
32.7
11.4
2-M 3 Depth 4
49.35
33
5.5 36
2-R 5.3 3 2-R 2.65
2.65
5.3
3
3.5
15 min.
3.8
11
4.2
38.5
11.5 14.55
Cable length: 1.8 m
18.66
21
41.56 Center of
scanning
67.6
22 3.5 21
19.6
48
38.1
2.2
23.47
48
2-M 3
3.5
15 min.
3.8
Depth4
4.2
11.5 Cable length: 2 m
6.45
48
5 E BL-1300-IM
*1
Specifications at 500 scans/second
Specifications
· The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in
accordance with the requirements of Laser Notice No. 50.
General specifications
· To comply with UL/IEC60950-1, use the limited power source defined in
Model BL-1300 BL-1301 BL-1300HA BL-1301HA UL/IEC60950-1.
Type Standard type High-resolution
· The internal settings of the unit are written to the internal memory.
Scanning direction Front (Re-writable 100,000 times)
Visible red semiconductor laser
Light source
(Wavelength: 660 nm)
Output 85 W Interface specifications
Pulse duration 112 s
Class 2 Laser Product 2 (IN1, 2), no-voltage input
Laser Class Input pin
(IEC60825-1,FDA(CDRH) Part 1040.10) (contact, non-contact)
Scan method Single Raster Single Raster Output type 4 (OUT1 to 4) NPN open collector
Focal distance 120 mm 90 mm Rating load 24 V DC, 30 mA
65 to 500 mm *1 45 to 270 mm *1 Output Leakage current at
Reading distance pin 0.1 mA or less
(When narrow width is (When narrow width is OFF
1.0 mm) 0.5 mm)
Residual voltage at
Reading bar width 0.125 mm or more 0.08 mm or more 0.5 V or less
ON
339 mm *1 189 mm *1 Transmission method EIA RS-232C compliant
Maximum reading label width (Distance 350 mm, (Distance 189 mm,
Narrow bar width 1.0 Narrow bar width 0.5 600, 1200, 2400, 4800, 9600, 19200,
Communication rate
mm) mm) 31250, 38400, 57600, 115200 bps
PCS 0.4 or more Serial Synchronization Start-stop synchronization
interface
Scan count 500 to 1300 scans/second Data length 7/8 bits
CODE39, ITF, Industrial2of5, Standard2of5, Stop bit length 1/2 bits
COOP2of5, CODABAR, CODE128,
Supported codes Parity check None/even/odd
GS1-128, CODE93,
UPC/EAN, GS1 DataBar
74 digits
Reading digit (148 digits for the CODE128 start character C)
Enclosure rating IP65 WARRANTIES AND DISCLAIMERS
Ambient light Sunlight: 10000 lx, Incandescent lamp: 6000 lx
Environment resistance
KEYENCE, at its sole option, will refund, repair or replace at no charge any
Ambient
0 to 45C defective Products within 1 year from the date of shipment. Unless stated
temperature
Storage ambient otherwise herein, the Products should not be used internally in humans, for
-20 to 60C
temperature human transportation, as safety devices or fail-safe systems. EXCEPT FOR
Relative humidity 35 to 85%, No condensation THE FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY
Operating WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY,
No dust or corrosive gas present
atmosphere FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF
Vibration
10 to 55 Hz, amplitude 1.5 mm, PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE
2 hours each in X, Y and Z directions
SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
Power supply
5V DC 5% CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT
Rating voltage
Power consumption 400 mA max.
FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY
SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE. In some
Weight Approx. 115 g
jurisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.
Model BL-1350HA BL-1351HA BL-1370 BL-1371
High-resolution, E 1101-3
Type Long distance type
side-scanning type
Scanning direction Side Front
Visible red semiconductor laser
Light source
(Wavelength: 660 nm)
Output 85 W
Pulse duration 112 s
Class 2 Laser Product
Laser Class
(IEC60825-1,FDA(CDRH) Part 1040.10)
Scan method Single Raster Single Raster
Focal distance 65 mm 230 mm
40 to 250 mm *1 160 to 600 mm *1
Reading distance (When narrow width is (When narrow width is
0.5 mm) 1.0 mm)
Reading bar width 0.08 mm or more 015 mm or more
Ambient
0 to 45C
temperature
Storage ambient
-20 to 60C
temperature
Relative humidity 35 to 85%, No condensation
Operating
atmosphere No dust or corrosive gas present
E BL-1300-IM 6
Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.
12900E 1014-1 96M12900 Printed in Japan
*96M12900-1*