Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Fans for ATEX EXPLOSIVE ATMOSPHERES

An ATEX area is a mixture of air and inflammable gas, the vapour of an inflammable liquid, a fog of combustible liquid
or combustible powder, which, if they catch fire, do so at once in their entirety.

Sensitivity to the ignition of gases:


LIE Minimum concentration of explosivity » % volume.
LSE Maximum concentration of explosivity » % volume.
EMI Minimum ignition energy » 10-6 μ Joules
Flash Point Minimum temperature of a liquid forms inflammable gases
Temperature – Temperature at which a gas ignites
temperature – T1, T2, T3, T4, T5 and T6

Sensitivity to the ignition of solids:


LIE or CME Minimum concentration explosive » g/m3
CLO Maximum concentration of Oxygen » % volume
EMI Minimum ignition energy » 10-3 μ Joules
TMI Minimum ignition temperature in ºC:
- In a TMI n cloud (a cloud of dust in contact with a hot surface).
- In a TMI c layer, ignition of a 5 mm layer.
- (limit of T the lesser of: 2/3 of TMI n or TMI c -75ºC)

Summary of definitions of the zones

Explosive atmospheres

Zone 2 (gas)
Zone 22 (dust)
II 3 G. EEx nA Not probable under normal oper-
ating conditions
II 3 D. IP55 (non-conductive dust)
II 2 D. IP65 (conductive dust)
Zone 1 (gas)
Zone 21 (dust)
Probable under normal operating
conditions

Zone 0 (gas)
Zone 20 (dust)
Electric motors
II 2 G. EEx d cannot be used
II 2 G. EEx de
II 2 G. EEx p
II 2 G. EEx e
II 2 D. IP65

Definition of zones: Groups and categories of apparatus:

Gases and vapours / Powders: GROUP I: Equipment for underground and surface work in
• Zone 0 / Zone 20: mines with danger of firedamp or explosive powders.
Present continuously, during long periods of time • M1 Category: must remain operative
or frequently. It is not possible to use electric motors. • M2 Category: it must be possible to cut off the energy supply
• Zone 1 / Zone 21:
It is probable in normal operating conditions GROUP II: Other danger zones
• Zone 2 / Zone 22: • Category 1: a very high level of protection. Highly probable area.
The creation of an ATEX zone is not probable under normal • Category 2: a high level of protection. Probable area.
operating conditions • Category 3: a normal level of protection. Improbable area.

10
Selection of the category according to the zone: Selection of the zone according to the category:

ZONE CATEGORY CATEGORY ZONE


0 or 20 1 1 All
1 or 21 1 or 2 2 1, 21, 2 or 22
2 or 22 1, 2 or 3* 3* 2 or 22
*The 3D category cannot be used with a conductive powder *The 3D category cannot be used with a conductive powder

Explosion group and kind of temperature


Explosion Kind of temperature
group
T1 T2 T3 T4 T5 T6
Acetone Carbon monoxide Amyl-i acetate Petrol Acetaldehyde
II A Ethane Methane Butane Otto fuels
Ethylic acetate Methanol N-butyl alcohol Aviation fuel
Ethyl chloride Methyl chloride Cyclohexane Fuel oils
Ammoniac Propane Dichloroethane 1, 2 Hexane
Benzene Town gas Acetic anhydride
Acetic acid Toluene

Ethylic alcohol Sulfureted Ethylic ether


II B
Ethylene hydrogen
Ethylene monoxide

II C Hydrogen Acetylene Carbon


disulphide

Kind of temperature and ignition temperature: Explosivity values for combustible solids

Kind of temperature Ignition temperature Product Kmax Pmax EMI CLO TMIn TIMc
T1 <450 Cornflour 127 6.7 300 -- 530 460
T2 300 to 450 Ground rice 40 6.7 >10 -- 370 480
T3 200 to 450 Wheat flour 47 8.2 >300 11% 460 470
Malted flour 100 7.8 >10 11% 310 460
T4 135 to 200
Corn starch 143 10.6 >100 9% 440 400
T5 100 to 135
Rice starch 220 10.0 >10 -- 470 390
T6 85 to 100
Potato starch 89 9.4 >3000 -- 520 570

Mark (EN) in accordance with ATEX

FAN and MOTOR marks in accordance with the


ATEX directive

0081 II 2 G/D

EC mark Identification EC mark for Electrical Category Gas or


of certifying Ex products apparatus of the Dust
authority groups equipment
(e.g. LCIE) (2 or 3)

Extra standard mark for motors

EEx d II C T4

Explosion- Groups according Group (all Protection Kind of


proof to Gas except mines) type temperature
(Only required for
apparatus flame-resistant)

11
HCDF HDF

HCDF HCDF: Axial fans with square frame,

HDF
with ATEX certification EEx d
HDF: Axial fans with circular frame, Mark: II 2 G. EEx d
with ATEX certification EEx d Notified authority: L.O.M.
ID: LOM3ATEX0157
Wall-mounted axial fans (HCDF) or circular axial fans (HDF) with
ATEX certification and CEE ExII2G EExd flame-resistant motor to
work in explosive atmospheres. Finish:
• Rust retardant with ATEX paint, free
Fan: of ferric components, in polyester
• Impeller made from cast aluminium resin, polymerised at 190ºC, with
• Airflow direction from motor to impeller prior alkaline degreasing and with
• Spark-proof stuffing-box included phosphate-free pre-treatment
HCDF • HCDF: Support frame in aluminium sheet
• HCDF: Protection guard against contacts, in accordance with On request:
standard UNE 100-250 • Special windings for different voltages
• HDF: Support ring in sheet steel with aluminium strip in the and frequencies
impeller area in accordance with Standard EN-14986:2006 • ATEX construction for different
categories
Motor: • Fans with two-speed motor.
• Class F motors with ball bearings, IP-55 protection,
with ATEX certification, EEx”d” IIBT4 flame-resistant
• Three-phase 230/400V.-50Hz. (up to 5.5CV.)
and 400/690V.-50Hz. (power over 5.5CV.)
HDF Aluminium strip to prevent
• Working temperature: -20ºC.+ 40ºC. sparks in accordance with
standard EN-14986:2006

Order code

HCDF 45 4T

HCDF: Axial fans with square frame, with ATEX Impeller diameter Number of T=Three-phase
certification (cm) motor poles M=Single-phase
HDF: Axial fans with circular frame, with ATEX
4=1400 r/min. 50 Hz
certification
6=900 r/min. 50 Hz
Mark: II 2 G. EEx d IIBT4
Notified authority: L.O.M.
ID: LOM3ATEX0157

Technical characteristics
Model Speed Maximum admissible Installed Maximum Sound pressure Approx. weight
current (A) power airflow level dB(A) (Kg)
(r/min) 230V 400V (kW) (m3/h)
HCDF-25-4T 1370 0.78 0.45 0.09 890 51 6.5
HCDF-25-4M 1410 0.72 0.06 890 51 6.5
HCDF-31-4T 1370 0.78 0.45 0.09 1700 54 7.5
HCDF-31-4M 1410 0.72 0.06 1700 54 7.5
HCDF-35-4T 1370 0.78 0.45 0.09 2950 58 8.5
HCDF-35-4M 1410 0.72 0.06 2950 58 8.5
HCDF-40-4T 1420 1.30 0.75 0.25 4400 63 12.5
HCDF-40-4M 1400 3.25 0.25 4400 63 15.0
HCDF-45-4T 1420 1.30 0.75 0.25 6450 66 14.5
HCDF-45-4M 1400 3.25 0.25 6450 66 17.0
HCDF-45-6T 925 0.95 0.55 0.12 5200 57 14.5
HCDF-50-4T 1390 1.73 1.00 0.37 8600 69 16.5
HCDF-50-6T 920 1.56 0.90 0.18 6300 59 16.0
HCDF-56-4T 1390 3.08 1.78 0.55 10500 72 36.5
HCDF-56-6T 910 1.59 0.92 0.25 8400 63 30.5

HDF-63-4T 1415 4.50 2.60 1.10 15100 76 49.0


HDF-63-6T 905 2.37 1.37 0.37 12400 64 36.5
HDF-71-4T 1400 5.20 3.00 1.10 20000 79 52.0
HDF-71-6T 900 3.29 1.90 0.55 13800 67 43.0
HDF-80-4T 1400 13.86 8.00 3.00 34100 83 76.0
HDF-80-6T 910 5.89 3.40 1.10 20200 72 65.5
HDF-90-4T 1400 15.42 8.90 4.00 48200 89 87.0
HDF-90-6T 920 7.45 4.30 1.50 30000 77 83.0

14
HCDF HDF

Acoustic features
The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of
twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m.
Sound power Lw(A) spectrum in dB(A) via frequency band in Hz.

Model 63 125 250 500 1000 2000 4000 8000 Model 63 125 250 500 1000 2000 4000 8000
25 22 37 56 55 56 55 50 41 56-6 37 51 70 70 71 69 65 56
31 25 40 59 58 59 58 53 44 63-4 52 66 85 85 86 84 80 71
35 29 44 63 62 63 62 57 48 63-6 40 54 73 73 74 72 68 59
40 34 49 68 67 68 67 62 53 71-4 56 76 84 89 91 88 81 70
45-4 37 52 71 70 71 70 65 56 71-6 44 64 72 77 79 76 69 58
45-6 28 43 62 61 62 61 56 47 80-4 60 80 88 93 95 92 85 74
50-4 43 57 76 76 77 75 71 62 80-6 49 69 77 82 84 81 74 63
50-6 33 47 66 66 67 65 61 52 90-4 67 88 95 100 103 99 92 81
56-4 46 60 79 79 80 78 74 65 90-6 55 76 83 88 91 87 80 69

Dimensions in mm

HCDF

Model A B C D E G H I J
HCDF-25-4T 330 275 262 260 228 11 41 132 8.5
HCDF-25-4M 330 275 262 260 235 11 41 132 8.5
HCDF-31-4T 400 336 310.5 308 234 11 50 132 10.5
HCDF-31-4M 400 336 310.5 308 241 11 50 132 10.5
HCDF-35-4T 465 390 362.5 360 245 11 50 132 10.5
HCDF-35-4M 465 390 362.5 360 252 11 50 132 10.5
HCDF-40-4T 532 452 412.5 410 265 11 70 132 10.5
HCDF-40-4M 532 452 412.5 410 295 11 70 132 10.5
HCDF-45-4T 596 504 462.5 460 262 11 70 132 10.5
HCDF-45-4M 596 504 462.5 460 290 11 70 132 10.5
HCDF-45-6T 596 504 462.5 460 262 11 70 132 10.5
HCDF-50-4T 665 562 516.5 514 262 11 70 132 10.5
HCDF-50-4M 665 562 516.5 514 262 11 70 132 10.5
HCDF-56-4T 710 630 563 560 370 15 105 162 10.5
HCDF-56-4M 710 630 563 560 370 15 105 162 10.5

HDF

Model A B C D E F J N
HDF-63-4T 730 690 645 640 370 150 12 12x30º
HDF-63-6T 730 690 645 640 330 150 12 12x30º
HDF-71-4T 810 770 715 710 349 150 12 16x22º30’
HDF-71-6T 810 770 715 710 323 150 12 16x22º30’
HDF-80-4T 900 860 805 800 421 180 12 16x22º30’
HDF-80-6T 900 860 805 800 371 180 12 16x22º30’
HDF-90-4T 1015 970 906 900 457 180 15 16x22º30’
HDF-90-6T 1015 970 906 900 415 180 15 16x22º30’

15
HCDF HDF

Characteristic curves
Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mm.w.c., Pa and inwg.

Accessories
See accessories section.

INT AR RFT/ RFM PANELS P R RI S

16