December 23, 2020 Ref. No. CP-0697-02: Presence Across The Country

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

December 23, 2020

Ref. No. CP-0697-02

Mahmood Ali Shaikh


Electrical Engineer
GASCO Engineering (PVT) Limited
504 Amber Estate, Shahra-e-Faisal,
Karachi-75350, Pakistan

Cell No: +92 336 2138340


Email: mahmood.sheikh@gascoengineering.com.pk

Subject: Revised Budgetary Offer for Design, Supply, Installation & Commissioning of CP
System for Nos. 02 Parallel Flowlines of 37.5 km span in Thar Region of Sindh
with specifications: 24’’ diameter, Wall Thickness 6.35 mm, API-5L, Grade X-42,
3LP Coated

Dear Sir,
This is with reference to your inquiry that we received for budgetary offer against subject services. We
are pleased to submit our competitive & revised proposal based on the requirement shared with us.

INTRODUCTION

InspecTest Private Limited is an integrated Inspection, Testing and Certification Solutions provider,
catering to the need of major local and foreign companies in Pakistan.

VISION
Creating an environment that is Safe, Caring and Reliable

MISSION
At InspectTest, we will never compromise people for growth. We will support and nurture our
employees to become the company’s greatest asset, adding value and ensuring sustainability for our
customers and the communities we live in.

WHY INSPECTEST
◼ Presence across the country
◼ Certified, qualified, and experienced technical human capital.
◼ State of art inspection, testing & calibration equipment
◼ Complying to the world-class HSE System
◼ Offering Highest levels of professionalism and integrity
◼ Cutting edge Technology
December 23, 2020
Ref. No. CP-0697-02

INSPECTEST CLIENTELE
◼ Oil & Gas
◼ Power & Energy
◼ Manufacturing & Engineering
◼ Fertilizers & Chemicals
◼ Drilling/Oil & Field Services
◼ Refineries & Petrochemicals
◼ FMCGs (Food & Beverages)
◼ Others

InspecTest Proficiencies for Cathodic Protection System

◼ InspecTest brings an experience of more than 20 years of Inspection services in Pakistan


◼ Iron Member of National Association of Corrosion Engineers (NACE) International
◼ ISO/IEC 17020:1998 Certified Inspection Company
◼ In house Design and Execution Team having NACE certifications of Corrosion Senior
technologist and NACE CP level 2 & 3
◼ Team Member of Institute of Corrosion, UK
◼ Official partner of Matcor, USA for all the services & products in Pakistan
◼ InspecTest brings experts having more than 10,000 km Survey experience in the field of ECDA
surveys for Underground Pipeline
◼ Successful CP Design, Installation and commissioning of more than 100 above ground storage
Tanks, buried Vessels, LPG Bullets and Underground buried piping
◼ Operation & Maintenance of CP systems of wells and associated above 20 wells each month

TECHNICAL PROPOSAL

SCOPE:
Design, Supply, Installation & Commissioning of CP System for Nos. 02 Parallel Flowlines of 37.5 km
span in Thar Region of Sindh with specifications: 24’’ diameter, Wall Thickness 6.35 mm, API-5L,
Grade X-42, 3LP Coated

Location / Site:
Thar – Sindh, Pakistan.
December 23, 2020
Ref. No. CP-0697-02

COMMERICIAL PROPOSAL

Sr. Total Price


Item Unit Quantity
No. (PKR)

1.0. Engineering & Design

1.1. Design Services Job 01

Sub-Total Price in PKR

2.0. Supply of Materials

1.1. MMP-3605 -BH0010MATCOR MMP™ canister Nos. 20


anode3 inch by 60 inches long10 foot #8 AWG
HMWPE anode lead cable Rated for 5 amps
continuous service for 25 years, MATCOR-USA

1.2. Transformer Rectifier Unit- Three Phase, Nos. 02


400V±10% AC Input, Single Channel (50V/50 A),
50Hz, DC, Oil Cooled, c/w interrupter. - For Non-
Hazardous Area Use. Make: Pakistan,

1.3. TR Oil Litres 160


1.4. Anode junction Box, IP 65, SS 304, Dust proof with Nos. 04
circuits for anode cable terminations

1.5. Negative Junction Box (NJB), 304 stainless steel, Nos. 02


IP65, with copper bus bar, for non-hazardous area.

1.6. Bond Box Mild steel, Dust proof Nos. 36

1.7. Splicing connector, 2 way with epoxy, Cable Nos. 20


jointing/ Cellpack, Germany

1.8. Vent Pipe (PVC Casing 1" Dia x 13 feet length) Nos. 30

1.9. Cad weld charges (Thermite weld) Nos. 100

1.10. Cad Weld Mould CA-16 Nos. 2

1.11. Cad Royston Handy Nos. 80

1.12. Flint Gun Igniter Nos. 4

1.13. Shunts 50mV, 50Amps Nos. 20

1.14. Rheostat – Multi turn wire wound Potentiometer Nos. 20


December 23, 2020
Ref. No. CP-0697-02

1.15. 1C*10 mm2, Stranded Cu/XLPE/PVC, 600/1000V,


Meter 500
Pakistan
1.16. 1C*16 mm2, Stranded Cu/XLPE/PVC, 600/1000V,
Meter 350
Pakistan

1.17. 1C*35 mm2, Stranded Cu/XLPE/PVC, 600/1000V,


Meter 450
Pakistan

1.18. 1C*25 mm2, Stranded Cu/PVC/PVC, Earthing cable Meter 180

1.19. Backfill (Metallurgical coke breeze) Kg 3000


1.20. Consumables Lot 01

Sub-Total Price in PKR

3.0. Installation/ Civil Works

3.1. Anodes bores (25 Ft deep & 08 Inches dia.) Nos. 20


3.2. Foundation For TR, 3 Ft x 3 Ft x 3 Ft Nos. 2

3.3. Foundation for Anode Junction Box + Bond Box, 2


Nos. 42
Ft x 2 Ft x 2Ft

3.4. Unskilled Labour (Per day) No of Labour = 02; No of


Days 150
days =75

3.5. Pits for Bond Boxes, 1 cubic meter Nos. 36

3.6. Civil Work Miscellaneous (Cable laying, excavation,


Trenches, sand padding & Tiles) 450m x 1.5 Ft x 3Ft Meter 450
Depth

3.7. CP Supervisor Days 120

Sub-Total Price in PKR

4.0. Testing & Commissioning Services


4.1. Testing & Commissioning Services Job 01

Sub-Total Price in PKR

5.0. Mobilization/ De-Mobilization Charges

5.1. Mob De-mob of Team & Equipment Lump Sum

Sub-Total Price in PKR

Grand Total PKR (Exclusive of Tax)


December 23, 2020
Ref. No. CP-0697-02

CLIENT’S RESPONSIBILITIES:
◼ Client shall inform InspecTest at least 10 working days prior to execution of job by issuance of
Work Order/Agreement or (equivalent document).
◼ Client shall provide food and accommodation to InspecTest personnel during stay at site free of
cost as per cadre.
◼ Client shall ensure security and safety of our manpower and equipment at site and, if required,
emergency medical facilities.
◼ Client shall arrange the Work Permits, plant entry requirements etc.
◼ Client shall ensure water availability throughout the job execution at Site
◼ Client shall provide Internet Facility to Site Staff during execution of job.
◼ Client shall arrange Single phase AC input supply

PROPOSAL NOTES:

◼ The quoted price is in PKR


◼ The subjected quote is exclusive of provincial sales tax (PST).
◼ Safe place for material storage is to be provided by Client.
◼ AC input supply cable and installation of input cable shall be in client's Scope.
◼ CP System Life 25 Years has been considered.
◼ No hazardous area equipment has been considered the proposed BOQ.
◼ BOQ assumes that both ends of the pipeline are electrically isolated through isolating gasket/
flange.
◼ Procurement and installation of Insulation gaskets and Surge Arrestors (if required) shall be in
GASCO Scope.
◼ Water for anode boring shall be provided by Client.
◼ Reference cells are not considered in the proposed BOQ.
◼ Design shall be made by CP NACE Level III.
◼ Commissioning Report shall be sign / stamped by CP NACE Level III.
◼ Only soil resistivity survey is considered in pre-design survey.
◼ Transformer Rectifier Unit is considered for ICCP system assuming the availability of AC
power source at site.
◼ In case of unavailability of AC power source alternate DC source shall be selected as per site
situation & same shall be incorporated in BOQ

PROPOSITION VALIDITY PERIOD:

◼ This quotation is valid for 30 days from the date of submission.


December 23, 2020
Ref. No. CP-0697-02

INVOICING AND PAYMENT TERMS & CONDITIONS:


◼ InspecTest shall raise invoice on stage completion basis at Project Site
◼ 20% Payment after submitting the first design draft
◼ 20% Payment after Design approval from HUBCO
◼ 30% Payment at the supply of Anodes
◼ 15% Payment at the supply of TRUs
◼ 10% Payment after getting the system energized
◼ 05% Payment after killing of punch list items

ESTIMATED DEILVERY TIMELINE

◼ Design: 02-03 weeks after approved PO.


◼ Supply: 08-12 weeks after the approval of design.
◼ Installation: 05-06 weeks after the supply at Site
◼ Commissioning: Within 3 weeks after the completion of Installation
BANK DETAILS:
◼ Bank Name: Habib Metropolitan Bank ◼ Address: 18 Km, Ferozepur Road
Branch
◼ A/C Title: InspecTest Private Limited ◼ A/C #: 06-02-95-20311-714-110092

COMPANY INFORMATION:
◼ InspecTest NTN No. 1273922-7
◼ Sales Tax Registration No. 03-93-9999-529-73
December 23, 2020
Ref. No. CP-0697-02

PROPOSAL GENERATED BY PROPOSAL REVIEWED BY


Muhammad Naveed Alam Ehsan Ullah

Lead Engineer Proposals Manager Sales

Hope you will find our proposal suitable, however, if you have any query/clarification and/or require
any details, please do contact us.

With Best regards,

_______________

Ehsan Ullah
Manager Sales
InspecTest (Private) Limited
18-km, Ferozepur Road, Lahore-54760 Pakistan.
T: + 92 42 3540 2053 - 58 I UAN: III-INSPEC I F: + 92 42 3540 2050 I M: + 92 321 8476713
E: ehsan.ullah@inspectest.com

(This is a computer generated document, therefore, signatures are not required)


December 23, 2020
Ref. No. CP-0697-02

INSPECTEST CERTIFICATIONS / MEMBERSHIPS

You might also like