Professional Documents
Culture Documents
Airflow Sensors AWM5000 Series High Flow Mass Airflow/Amplified
Airflow Sensors AWM5000 Series High Flow Mass Airflow/Amplified
FEATURES
1 Variety of flow connections possible
1 Venturi design
1 Remote mount
1 Active laser trimmed to CO2, N2 or
argon calibration
Figure 1 NOMINAL
VALUES
R1 J 3.3K
In-Line Flow Measurement R2 J 5.0K
AWM5000 Series Microbridge Mass Air- R3 J 1.82K
flow Sensors feature a venturi type flow R4 J 24.9K
housing. They measure flow as high as 20 R5 J 24.9K
R7 J 200K
standard liters per minute (SLPM) while R8 J 32K
inducing a maximum pressure drop of R9 J 9.0K
2.25N H2O. The microbridge chip is in di- R10 J 1.0K
rect contact with the flow stream, greatly R11 J 10K
reducing error possibilities due to orifice R12 J 400K
or bypass channel clogging. R13 J 3.5K
R14 J 5K
Rugged, Versatile Package R15 J 5K
The rugged plastic package has been de- R16 J 400K
R17 J 400K
signed to withstand common mode pres- R18 J 9K
sures up to 50 psi, and the small sensing R19 J 1K
element allows 100 g’s of shock without Ra J 500
compromising performance. The ports Figure 2 Rb J 3.0K
are separate moldings which can be Rc J 1.0K
modified for alternative fittings with a mini- Rr J 6.0K
mum of tooling cost or performance im- Rh J 800
pact. The snap-in ‘‘AMP’’ compatible Ru J 1.5K
Rd J 1.5K
connector provides reliable connection in
demanding applications.
70 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Airflow Sensors AWM5000 Series
Highflow Mass Airflow/Amplified
SPECIFICATIONS
Suffix - Calibration gas VA - Argon (Ar) VC - Carbon dioxide (CO2) VN - Nitrogen (N2)
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 71
Airflow Sensors AWM5000 Series
High Flow Mass Airflow/Amplified
OUTPUT CURVES
72 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Airflow Sensors AWM5000 Series
Highflow Mass Airflow/Amplified
AWM5000 ORDER GUIDE
NOTE: All listings have 1 - 5 VDC linear output with 10 VDC supply over given flow range for a gas.
1. N2 calibration is identical to 02 and air calibration.
2. CO2 calibration is identical to N2O calibration.
OUTPUT CONNECTIONS
Pin 1 + Supply voltage
Pin 2 Ground
Pin 3 No connection
Pin 4 Output voltage
Flow direction indicated on housing
Airflow
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 73