Service Information
Washing machine Frontloader
AWOE 91400
8592 460 10000
Last Modification: 08/08/09
Creation Date: 26/06/09
Exploded View 5
Technical Data 7
Wiring Diagram 9
Circuit Diagram 11
Program Chart 13
Testprogram 26
Error Codes 27
This document is only intended for qualified technicans who are aware of the
respective safety regulations.
Subject to modifications
Exploded View
Exploded View
Technical Data
Dimensions + Weight
Product dimensions
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85.0 cm
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 cm
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 cm
Weight
net . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 kg
Drum data
Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 l
Wash speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 rpm
Spinning
max. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400 rpm
Pressostat
Level1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12/14
Overflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 16
Door lock
Kind of switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch with PTC heater of bimetal
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 (90 - 264) V
Locking time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 6 s
Unlock time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~85 s
Inlet valve
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 - 240 V / 50 Hz
Rated flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (1.5 - 5 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 l/min
Pressure range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 - 10 bar
Nominal resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (20 °C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8 kΩ
Drain pump
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 - 240 V / 50 Hz
Total power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 W
Resistor (coil) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 Ω
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (0.55 - 1 m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ± 2 l/min
Heating element
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V + 10 %, -15 %
Total power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2050 W
Resistance (20 °C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Ω
Leakage current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.8 mA
NTC sensor
Resistance NTC
0 °C 35.9 kΩ
30 °C 9.8 kΩ
40 °C 6.6 kΩ
50 °C 4.6 kΩ
60 °C 3.2 kΩ
70 °C 2.3 kΩ
95 °C 1.1 kΩ
Motor
Resistance contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (20 °C)
Stator (full field) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.20 Ω
Stator (tapped field) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.51 Ω
Rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.72 Ω
Tacho generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184.00 Ω
Control unit
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOMINO
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220-240 V / 50 Hz
Output control unit
Wiring Diagram
Legend
Circuit Diagram
Legend
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Program Chart
Testprogram
Error Codes
Error Codes
Error Codes
Error Codes
Error Codes
REMEDIAL ACTION
In case the original foot is broken, we recommend to order foot: 4812 462 48054.
REMEDIAL ACTION
When replacing the Core 08 door, you have to exchange the front panel and screws as well!
Attention: Silver Core08 doors will be substituted with a black door! See table below:
Estimated availability date of the new (SIGMA) Front panels in SPC is wk 19/2013.
161 1400 AX A
REMEDIAL ACTION
In case of damages on the door bellow due to grease residues, please exchange the door bellow & TL feets with follow
order codes.
The compound used for the seal will be more rigid than the original therefore it will be mandatory to replace the feet
with the one used for top loaders to avoid vibration!
161 1910 AX A
REMEDIAL ACTION
Check motor function
=> If motor is not running at all: check for Motor failure F06
=> If motor is running:
Unbalance:
• Unbalance measurement can lead to repeated laundry distribution ramps to come down with measured unbalance. De-
pending on the model it can be a high number of retrials. This is necessary to avoid mechanical damages of the appliance
due to spinning with too high unbalance. If it is not possible to reach an acceptable unbalance level with the distribution
retrials, the appliance will not spin.
• Small loads and especially single pieces are more critical than middle and large loads => check with customer for load
conditions – instruct customer
• In case of selecting Drain & Spin-program, the unbalance measurement is more critical, because information from the
wash cycle is missing. Therefore is a higher probability for retrials in the distribution ramps and eventually for failing spinning
at all. Check with customer, if Drain & Spin-cycle was selected or if a complete washing program was selected.
Foam creation:
• If during ramp-up for spinning – intermediate spins or final spin – the pressure switch contact is closed (wash level L1) due
to water ring, foam or partly blocked outlet system (foreign objects, wrong assembly of internal or external hoses, etc.) the
foam routine is started.
• If during ramp-up the wash level L1 is detected, the motor stops and the drain pump runs for 30 sec. When reaching level
L0 within 30sec., the ramp-up is repeated. Depending on the model, this can happen up to 3 or up to 5 times.
If foam creation is the cause, then give an advice to the customer to use detergent acc. to the dosing recommendation
given by the detergent supplier. On machines with serial number 341020... or 411020...and lower reprogramme the control
board by ESAM with the latest update.
Frequency variation:
• Instable mains frequency can have negative impact on unbalance detection. If the frequency variation is limited to a short
period, it will lead to additional retrials for distribution. In case of "permanent"frequency variation, it can lead to no spinning
after number of retrials is expired.
If a frequency variation is the cause of the problem, then exchange the control board by the service kits mentioned in
the table below. According to SPC the kits will be available from week 50/2010 onwards.
Each service kit is containing a new basic WAVE control board (CCU) that needs to be programmed by ESAM (with new
SKU), new door lock and wiring between door lock and CCU.
When the appliance is equipped with the new parts it has got the new revision state. That means the 12NC of the machine
has to be changed to the new 12NC code according to the table below by the service technician on each sticker of the
appliance.
One sticker is placed on the inner side of the door and one sticker on the rear panel of the appliance.
Note: A limited number of kits with programmed WAVE boards is shown on the last page.
REMEDIAL ACTION
If all other relevant possibilities according F06 failure tree are not applicable, remove the pulley and check if worn out. Once
the screws has been removed check the connection between pulley and drum shaft, the aluminium inner surface that lays
flat on the shaft shall not be worn out.
(See drawing)
A2B 2720 Ax A
F2S Number
REMEDIAL ACTION
If the heating element gets broken under mentioned conditions we recommend using the alternative heating element that is
nickel treated and usable for power supply up to 240V.
REMEDIAL ACTION
In case of an exchange of the CCU, please follow below‘s instruction for the new keying of the motor cable connector.
KXX 5210 PX A
REMEDIAL ACTION
Pressure switch Failure
This failure code can be also generated by a defect heater or a defect drain pump or bad harness connections to heater or
drain pump.
To exclude the drain pump and the heater as root cause, please check:
1. Check if the drain pump is running and check for foreign objects in the filter (see F03)
2. Inverse the mains plug polarity (by turning the mains plug or by changing polarity of single connectors of the power cord
on the RFI Filter => ATTENTION: unplug appliance from mains before touching the single connectors!!!)
If with inversed polarity failure code remains F23, continue with checks for Pressure switch. If with inversed polarity failure
code changes to F12, check for Heater failure F12.
Potential Causes
• Check the wiring connections between the pressure switch and the CCU (2 connectors on pressure switch and 2 connec-
tors on CCU)
• Check for proper operation of the pressure switch contacts (without water: 11-14 open, 11-12 closed, with water: 11-14
closed, 11-12 open).
Check the electrical resistance of the pressure switch for open and closed contacts without and with water.
• Start the Service program. If the problem persists the Error Code F23 will be displayed.
• If no issue found, check other points from hydraulic system like blocked air trap or blocked pressure switch hose (see
failure F01 and F03)
If these actions do not solve the issue and all parts like pressure switch and heating element are working correctly, then
exchange the control board by the new version indicated in the table below.
REMEDIAL ACTION
In order to assure a complete rinse out of the detergent the time of water inlet into the main wash department has been
prolonged.
When such a claim appears, the control board has to be reprogrammed by eSAM. It’s possible to put the new variant files
on old SAM by downloading via Divas database. In the last complete SAM database for the old SAM db_2072 the new files
are NOT included.
REMEDIAL ACTION
1. In case the door doesn’t close properly, the position of door needs to be checked. If the door is in correct position, the
door hook itself needs to be checked. If the distance A between door hook and body of door hook is less than 7.6mm it
needs to be replaced. The SCs are:
4801 111 01377 (black) and
4801 111 00211 (white)
.
REMEDIAL ACTION
2. In case the door doesn’t unlock even after removing the power supply and waiting for at least 6 minutes, the door lock
should be exchanged. The service code is: 4801 111 01392. In SPC all old door locks are removed and only the newest
version is available.
.
Cables
Frontloader SC1 / SC1 SC1
Omega Alpha Gamma
Delta PP Metaltub Plastictub Integrated
Cable from CB
to
Aktivatormotor - 481232178265 - - - 481232178271
Doorlock 481232178266 481232178267 481232178272 481232178272 481232178273 481232178274
NTC 481232178275 481232178276 481232178277 481232178277 481232178278 481232178279
Heater 481232178281 481232178282 481232178283 481232178283 481232178283 481232178284
Pump 481232178285 481232178286 481232178287 481232178288 481232178289 481232178291
UI - 481232178292 481232178293 481232178293 - -
UI with LCD - 481232178294 - - - -
Valve 481232178295 481232178296 481232178297 481232178297 481232178298 481232178299
Valve hot 481232178301 - 481232178302 481232178302 - -
SC1A2, Alpha
Alpha AA2/LR
SC1A3 AA2/HR
Toploader Omega 2 Omega 3 SC1/LR Plastic
SC1A3VBL/ Plastic
traverse
HR traverse
Cable from CB
to
Aktivatormotor 481232178268 481232178268
Doorlock 481232178269 481232178269 481232178303 481232178303 481232178305 481232178307
Rast 5 – 5pol Rast 5 - 3pol
Doorlock only
for SC1A3 ->
- - - 481232178308
rast 5
2- pol
NTC 481232178309 481232178311 481232178312 481232178312 481232178313 481232178315
Heater 481232178316 481232178316 - - 481232178318 481232178321
Heater
HE1-PR21 - - 481232178322 481232178323
only for SC1A
Heater
HE2-PR24 - - 481232178324 481232178325
only for SC1A
Pump 481232178326 481232178326 481232178326 481232178326 481232178327 481232178329
UI Whirlpool 481232178331 481232178331 - 481232178332 481232178333 481232178333
UI Bauknecht 481232178334 481232178334
Valve 481232178335 481232178335 481232178336 481232178336 481232178337 481232178339
Omega2
Board with 481232178341 - - -
special Valve
Valve hot - - - 481232178342
Frontloader
Eureka/Domino Delta/ Domino
Delta/Eureka
Cable from CB
to
Pump
480111100714 481232178364
Pressostat 11,
480111100716 481232178361
14
Pressostat
480111100717 481232178362
16,12
NTC 480111100718 481232178359
Toploader
Domino/Wave
Alliance
Cable from CB
to
Pump 480111100728
Heater 480111100729
Pressostat 11,
480111100731
14
Pressostat
480111100732
16,12
NTC 480111100718
Motor 6-pol 480111100733
Filter 480111100734
Doorlock 480111100735
Valve 480111100736
Switch
480111100725
Aquastop
UI 12- pol 480111100737
UI 4- pol 480111100738
UI 8- pol 480111100739
The remaining time of 0:01 and the door blocked at the end of the cycle fits to the wrong (low) resistance of the NTC.
REMEDIAL ACTION
1. Switch on the washing machine without to start any progamm and wait for 2 minutes.
3. Unplug the NTC cable set at the CCU and measure the NTC resistance at the connector.
(Attention: It is important that tere are only few seconds between the disconnection of the appliance and the measurement!!!)
4. In case the NTC is outside of specification (low resistance) replace the NTC.
SB:481271240367
SymptomCode:A1C
ComponentCode:6910
DefectCode:1X
RepairActionCode:A
A1C 6910 1X A
REMEDIAL ACTION
In case to exchange single components (Dispenser &/or Drawer), follow below mentioned overview of Dispenser Units.
X30 7110 AX A
REMEDIAL ACTION
After repair of venting hose or equalization tank check that the hose is fixed in the clips at the equalization tank. at shown
below to avoide kinks and contact with mains connection.
REMEDIAL ACTION
cb8b5452.png
X30 7630 A1 A
That might be result in bad drain performance, bad spin performance and noise.
At worse case a siphon effect can occur.
REMEDIAL ACTION
In case of washing machines with exhaust hose tub/tank, please check in any case of wash unit replacement, if the the
ventilation hole at the rear of the wash unit is open.
If not, please open the pipe with a carpet knife or similar knife to make sure, the ventilation functionality is always given.
F2S Number
REMEDIAL ACTION
In case of noise coming from the drain hose knocking on the side panel during a washing cycle, check the position of the
inner drain hose. If the hose touches the cabinet, fix it in a position, where it doesn’t touch the cabinet.
Machines with the old drain hose without rigid part (models without equalization tank produced before week 40/2009 ;
models with equalization tank produced before week 14/2010) can be equipped with the "new"drain hose:
models without eq-tank: 4801 111 00272; models with eq-tank: 4801 111 00206.
If after repositioning the hose is still creating knocking noise, install the noise insulation 4812 310 19136 and the side
brace 481246448161 on the side panels.