VF3031 SMC Electrovalvula
VF3031 SMC Electrovalvula
VF3031 SMC Electrovalvula
ption:
nsum
er co
pow
educed ing circuit]
w
R er sav
5
pow
0.5 w
[With
5
ard]
[Stand
Series VF3000
1.5 nvention
al: 2.0 W
) With
DC light
Built-in full-wave rectifier (AC)
Noise reduction
(Co Noise is considerably reduced by changing it to DC mode
Power consumption is reduced with a full-wave rectifier.
Standard
1.55 W
Energy saving
0.55 W
With power saving circuit
0W
40 ms
Strainer
Low wattage
New specification added
VF1000/3000
VF3000
(P)
M5 x 0.8
0.76
VF5000 1/8
(A)4 2(B)
(EA)5 1 3(EB)
(P)
L-type plug
2-position double connector
VF1000
VF3000 (B)2 4(A)
VF3000
VF5000 1/8
4.0 (A)4 2(B)
Page 1
1/4 M-type plug
(EA)5 1 3(EB) connector DC
(P)
With surge
voltage
3-position closed center suppressor
(A)4 2(B)
With light/surge
VF5000 (EA)5 1 3(EB) voltage
(P)
suppressor Push-turn
12 VDC locking
3-position exhaust center 24 VDC DIN With surge slotted type
(A)4 2(B) terminal voltage
24 VAC
1/4 100 VAC suppressor
8.8 (EA)5 1 3(EB)
(Non-polar)
(P)
3/8 200 VAC
3-position pressure center 110 VAC With light/surge
(A)4 2(B) voltage
220 VAC suppressor
(EA)5 1 3(EB) 240 VAC (Non-polar)
(P)
AC
VF3000 With light/surge
2-position single DIN (EN1753 Push-turn
(A)4 2(B)
voltage
01-803) suppressor locking
terminal lever type
(EA)5 1 3(EB)
(P)
(EA)5 1 3(EB)
(P)
New Low wattage specification From page 26 Power consumption: 0.35 W (Without light) 0.4 W (With light)
Features 1
Series VF1000/3000/5000
Model Selection by Operating Conditions
Manifold
EXH port Manifold Applicable Applicable
Series
type base model valve stations
VF1000 VV5F1-30
4(A), 2(B) port
M5,1/8
Common EXH
5/3(R) port
1(P) port 1/8
1/8 VF1 30 2 to 20
VV5F1-31 4(A), 2(B) port
VF1 33 stations
M5, 1/8
Individual EXH
1(P) port
1/4
VF5000 VV5F5-20 4(A), 2(B) port
1(P) port
3/8 VF5 20
VV5F5-21 4(A), 2(B) port VF5 23
1(P) port
1/2
VF3000 VV5F3-40
5(R), 3(R) port
1/4
VF3 40 2 to 20
Common EXH 1(P) port VF3 43 stations
1/4
Base mounted
2 to 10
Common EXH VF5 44
stations
1(P) port
3/8
4(A), 2(B) port
1/4
Features 2
Cylinder Speed Chart
Use as a guide for selection.
Please check the actual conditions with SMC
Model Selection Program.
Body Ported 0.5 MPa = 73 psi
Bore size
Series CJ2 Series CM2 Series MB, CA2 Series CS1
Average
Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series speed
Load factor 50% Load factor 50% Load factor 50% Load factor 50%
(mm/s)
Stroke 60 mm Stroke 300 mm Stroke 500 mm Stroke 1000 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160
1000
800 Perpendicular,
upward actuation
600
VF1120-01 Horizontal actuation
400
200
0
1000
800
600
VF3130-02
400
200
0
1000
800
600
VF5120-03
400
200
0
With : when using steel piping
Front matter 1
Cylinder Speed Chart
Use as a guide for selection.
Please check the actual conditions with SMC
Conditions Model Selection Program.
Body Ported
Body ported Series CJ2 Series CM2 Series MB, CA2 Series CS1
Tubing x Length T0604 x 1 m T0806 x 1 m —
VF1120-01 Speed controller AS3002F-06 AS3002F-08 —
Silencer AN101-01 —
Tubing x Length T0604 x 1 m T1075 x 1 m —
VF3130-02 Speed controller AS3002F-06 AS4002F-10 —
Silencer AN110-01 —
Tubing x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
VF5120-03 Speed controller AS3002F-06 AS4002F-10 AS4002F-12
Silencer AN30-03 AN302-03
Base Mounted
Base mounted Series CJ2 Series CM2 Series MB, CA2 Series CS1
Tubing x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m —
VF3140-03 Speed controller AS3002F-06 AS4002F-10 AS4002F-12 —
Silencer AN30-03 —
Tubing x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
VF5144-04 Speed controller AS3002F-06 AS4002F-10 AS4002F-12
Silencer AN40-04
Front matter 2
Pilot Operated 5 Port Solenoid Valve
Series VF1000/3000/5000
Single Unit
Note) Only DIN and conduit
Body Ported terminal types are
available with AC mode. RoHS
Refer to the electrical
How to Order Valve entry for details.
Body ported VF 3 1 3 0 5 G 1 01
Series
1 VF1000
Bracket
Type of actuation Nil Without bracket
3 VF3000 1 2-position single Thread type
5 VF5000 F With bracket
2 2-position double Nil Rc
VF1000/3000
3 3-position closed center F G Single type
4 3-position exhaust center N NPT (The bracket cannot be
5 3-position pressure center T NPTF connected after
M5 is available delivered.)
Only 1 and 2 are available with the VF1000.
with Nil only.
Body model
Symbol VF1000 VF3000 VF5000 Pressure specifications
2 — Nil Standard (102 psi (0.7 MPa))
3 — — K High-pressure type (145 psi (1 MPa))
VF1000
Body option Coil specifications Double type
Nil Standard only
0: Pilot valve individual exhaust
T With power saving circuit (DC only)
Note) Be sure to select the power saving circuit type
when it is continuously energized for long
periods of time. (Refer to page 51 for details.)
PE port EA/EB port T type is available with DC mode only. When T is
Not available with the VF5000.
VF1000 VF3000 VF5000 selected, only Z type of light/surge voltage
suppressor is available. (Note that when the electrical
entry of DIN terminal type without connector is Made to Order
3: Main/Pilot valve common selected, only DOS and YOS are available.) Nil —
exhaust Rated voltage Pilot exhaust port with piping thread (M3)
X500 specification (Refer to page 14.)
DC AC (50/60 Hz)
5 24 VDC 1 100 VAC TRIAC output specification
PE port EA/EB port X600 (Refer to page 14.)
6 12 VDC 2 200 VAC
VF1000 VF3000 VF5000
3 110 VAC [115 VAC]
—
4 220 VAC [230 VAC] A, B port size
Refer to “Made to Order” (Page 14) 7 240 VAC Symbol Port size VF1000 VF3000 VF5000
when piping to PE port is required. M5 M5 x 0.8 — —
B 24 VAC
01 1/8 —
Electrical entry 02 1/4 —
L-type plug M-type plug DIN DIN (EN175301-803) Conduit 03 3/8 — —
Grommet
connector connector terminal terminal terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible] Manual override
Nil: Non-locking D: Push-turn locking E: Push-turn locking
push type slotted type lever type
Specifications
Model VF1000 VF3000 VF5000
Fluid Air
Series VF1000
2-position single/3-position 22 to 102 psi (0.15 to 0.7 MPa)
Operating Standard
2-position double 15 to 102 psi (0.1 to 0.7 MPa)
pressure High-
pressure 2-position single/3-position
range 22 to 145 psi (0.15 to 1.0 MPa)
type 2-position double 15 to 145 psi (0.1 to 1.0 MPa)
Ambient and fluid temperature 14 to 122°F (–10 to 50°C) (No freezing)
Series VF3000 Max. operating 2-position single/double 10 10 5
frequency (Hz) 3-position — 3 3
Non-locking push type
Manual override Push-turn locking slotted type
Push-turn locking lever type
Pilot exhaust type Individual exhaust, Main/Pilot valve common exhaust (Except VF1000)
Lubrication Not required
Mounting orientation Unrestricted
Series VF5000 Impact/Vibration resistance (m/s2) Note) 300/50
Enclosure Dustproof (IP65 for D, Y, T)
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main
valve and armature in both energized and de-energized states every once for each condition.
(Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both
energized and de-energized states in the axial direction and at the right angles to the main valve and
armature. (Values at the initial period)
Based on IEC 60529. When using IP65, select the main/pilot valve common exhaust type.
Madeeto
Ord r Made to Order Solenoid Specifications
(Refer to page 14 for details.)
Symbol Specification Grommet (G), (H) DIN terminal (D)
Pilot exhaust port with piping L-type plug connector (L) DIN (EN175301-803) terminal (Y)
X500 Electrical entry M-type plug connector (M) Conduit terminal (T)
thread (M3) specification
X600 TRIAC output specification G, H, L, M D, Y, T
Coil rated DC 24, 12
voltage (V) AC (50/60 Hz) 24, 100, 110, 200, 220, 240
Allowable voltage fluctuation 10% of rated voltage
Power (W) Standard 1.5 (With light: 1.55) 1.5 (With light: 1.75)
consumption DC With power saving circuit 0.55 (With light only) 0.75 (With light only)
24 V 1.5 (With light: 1.55) 1.5 (With light: 1.75)
Apparent 100 V
110 V [115 V]
power (VA) AC
200 V 1.55 (With light: 1.65) 1.55 (With light: 1.7)
220 V [230 V]
240 V
Surge voltage suppressor Diode (Non-polar type: Varistor)
Indicator light LED (Neon light is used for AC mode of D, Y, T.)
It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
Allowable voltage fluctuation is –15% to +5% of the rated voltage for 115 VAC or 230 VAC.
Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the allowable voltage
fluctuation should be within the following range.
Response Time 24 VDC: –7% to +10% 12 VDC: –4% to +10%
2
Series VF1000/3000/5000
Flow-rate Characteristics/Weight
3
Series VF1000/3000/5000
Pilot Operated 5 Port Solenoid Valve
Body Ported/Single Unit
VF3000
VF5000 (A)4 2(B)
3 1 5 5 1 3
(EA)5 1 3(EB) (EB) (P) (EA) (EA) (P) (EB)
(P)
2-position double
Symbol
2-position single
VF1000 (B)2 4(A)
(B) (A) (A) (B)
2 4 4 2
(EB)3 1 5(EA)
(P)
VF3000
VF5000 (A)4 2(B)
3 1 5 5 1 3
(EA)5 1 3(EB)
(P)
(EB) (P) (EA) (EA) (P) (EB)
(EA)5 1 3(EB)
(P)
(EA)5 1 3(EB)
(P)
Component Parts
No. Description Material Note
1 Body Aluminum die-casted White
2 Adapter plate Resin Gray
VF313 -F
3 End plate Resin : Aluminum die-casted White
VF1120-F
4 Piston Resin
5 Spool valve Aluminum, HNBR
6 Spring Stainless steel
Replacement Parts
No. Description Part no. Note
7 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 5. Built-in strainer
4
Series VF1000/3000/5000
How to Order Pilot Valve Assembly (With a gasket and two mounting screws)
Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit type),
or vice versa.
Valve model: VF
Select from the below in accordance with the valve used.
5 G Z 1
Grommet or L/M-type
V2 11 5 G Z
Light/Surge voltage suppressor DC AC
Nil Without light/surge voltage suppressor
Note)
S With surge voltage suppressor —
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar) —
V211
U With light/surge voltage suppressor (Non-polar) —
Pilot valve assembly
Note) S type is not available with AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.
Caution
When using the surge voltage suppressor type, residual
voltage will remain. Refer to page 51 for details.
Electrical entry
G Grommet (Lead wire length 300 mm)
H Grommet (Lead wire length 600 mm)
L With lead wire
L-type plug
LN connector
Without lead wire
LO Without connector
M With lead wire
M-type plug
MN connector
Without lead wire
MO Without connector
LN and MN types are with 2 sockets.
Refer to page 49 when different length of lead
wire for L/M-type plug connector is required.
V2 12 5
DIN connector
(Refer to page 50.)
Caution
For V212 (DIN or Conduit type), the coil specifications and voltage (including light/surge voltage suppressor) cannot be changed by replacing
the pilot valve assembly.
Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.24 lbf·ft (0.32 N·m)
5
Series VF1000/3000/5000
Pilot Operated 5 Port Solenoid Valve
Body Ported/Single Unit
2-position single
G G
Grommet (G) (H): VF1120- H 1-M5 (-F) Grommet (G) (H): VF1120- H 1-01 (-F)
M5 x 0.8 1/8
6 14.8 [4(A), 2(B) port] 11.5 12
[4(A), 2(B) port]
(1 ista een
6. n p
(11 tanc
(D etw
6) ce or
Manual override Manual override
(D
b
.7)
is
1.7
1.7
26.4
26.4
4A 4A
12
10
eb
2B 2B
ts)
etw
ee
(1.6) (1.6)
G: Approx. 300 41.5 G: Approx. 300 41.5
np
H: Approx. 600 H: Approx. 600
ort
80 (6) 80 (6)
s)
(Lead wire length) (13 (Lead wire length)
.
(D 4)
(Indicator light) betwistanc
een e
por
ts)
- +
44.5
5EA
(45)
(55)
35
14.5 6
21.5
17.5
3EB
M5 x 0.8
[5(EA), 3(EB) port] 12 11.8 2 x ø5.5 (16)
(For mounting)
(26)
ø2.2 M5 x 0.8, 1/8
[1(P) port]
1.3
(PE port)
1P
Grommet (G) (H)
DC without light/surge voltage suppressor
17.8
43.4
10 12.8
2 x M4 x 0.7 thread depth 5 5EA
15.8
G: Approx. 300
12.5
Pg9
5EA
84.5
75.5
21.8
3EB
5EA
3EB
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
Max. 10 89.2
Approx. 300
Pg9
88.7 [78.7]
78.7 [68.7]
55.5
5EA 5EA
3EB 3EB
6
Series VF1000/3000/5000
Dimensions: Series VF1000/Body Ported (mm)
2-position double
G G
Grommet (G) (H): VF1220- H 1-M5 Grommet (G) (H): VF1220- H 1-01
(
M5 x 0.8 1/8 (D 16.
b por
[4(A), 2(B) port]
sta n
[4(A), 2(B) port] tw c
.7)
po een e
(4)
Manual override Manual override rts
)
1.7
1.7
26.4
26.4
4A 4A
10
12
2B 2B
6 11.5
1.7
1.7
G: Approx. 300 47.5 G: Approx. 300 47.5
H: Approx. 600 124.4 H: Approx. 600 124.4
(Lead wire length) (Lead wire length)
(1
(Indicator light) bet (Dis 3.4)
wee tan
n p ce
orts
)
- +
44.5
5EA
6
21.5
3EB 14.5
M5 x 0.8 12
(5.5)
(PE port)
1P
DC without light/surge voltage suppressor
1.3
51.3
10
12.5
3EB
15.8
5EA
G: Approx. 300
2 x M4 x 0.7 thread depth 5 H: Approx. 600 126.8
(For mounting bracket) (Lead wire length)
Pg9
5EA
84.5
75.5
21.8
3EB
5EA
3EB
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
Max. 10 142.9
Approx. 300
Pg9
88.7 [78.7]
78.7 [68.7]
55.5
5EA 5EA
3EB 3EB
7
Series VF1000/3000/5000
Pilot Operated 5 Port Solenoid Valve
Body Ported/Single Unit
2-position single
G
Grommet (G) (H): VF3130- H 1- 01
02 (-F)
1/8, 1/4
[4(A), 2(B) port] 10 25.5 2 x ø4.3
Manual override (For mounting)
1.7
4A
26.4
20
2B
23 19
(1.6)
G: Approx. 300 67
H: Approx. 600 105.5 (6)
(Lead wire length)
(Indicator light)
(10)
- +
44.5
(45)
(55)
31.5
35
21.5
17.5
7
1/8, 1/4
(For mounting) (26) Grommet (G) (H)
[1(P) port] (18.4) (
18.4)
DC without light/surge voltage suppressor
1/8 (Distanc
e betwe
[5(EA), 3(EB) port] en ports
)
1.3
1P 3EB
8
15.8
5EA
G: Approx. 300
ø2.2 36 12.5 H: Approx. 600 106.7
(PE port) 30.5 (Lead wire length)
68.9
D
L-type plug connector (L): VF3130- L 1- 01
02 (-F) DIN terminal (D) (Y): VF3130- Y 1- 01
02 (-F)
Max. 10 112.3
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 111.8
(Lead wire length)
Pg9
84.5
75.5
21.8
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
Max. 10 114.7
Approx. 300
Pg9
88.7 [78.7]
78.7 [68.7]
55.5
8
Series VF1000/3000/5000
Dimensions: Series VF3000/Body Ported (mm)
2-position double
G
Grommet (G) (H): VF3230- H 1- 01
02
1/8, 1/4
[4(A), 2(B) port] 23 2 x ø4.3
Manual override 10 (For mounting)
1.7
4A
26.4
20
2B
1.7
73
G: Approx. 300
H: Approx. 600 149.9
(Lead wire length)
(Indicator light)
- +
44.5
31.5
21.5
2 x ø4.2
20.5
(For mounting)
Grommet (G) (H)
1/8, 1/4
DC without light/surge voltage suppressor
[1(P) port] (18.4)
1/8 (18.4)
(Distan
[5(EA), 3(EB) port] ce betw
een po
rts)
1.3
1P 3EB
15.8
5EA
1.3
D
L-type plug connector (L): VF3230- L 1- 01
02 DIN terminal (D) (Y): VF3230- Y 1- 01
02
Max. 10 163.6
Pg9
84.5
75.5
21.8
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
Max. 10 168.4
Approx. 300
Pg9
78.7 [68.7]
55.5
9
Series VF1000/3000/5000
Pilot Operated 5 Port Solenoid Valve
Body Ported/Single Unit
4A
26.4
20
2B
1.7
36.5 52.5
G: Approx. 300 75
H: Approx. 600 165.9
(Lead wire length)
(Indicator light)
- +
44.5
31.5
21.5
7
2 x ø4.2 20.5
(For mounting) Grommet (G) (H)
1/8, 1/4 DC without light/surge voltage suppressor
[1(P) port] (18.4) (18
1/8 .4)
(Distance be
tween ports
[5(EA), 3(EB) port] )
1.3
1P 3EB
15.8
5EA
1.3
2 x ø2.2 36
8
76.2
G: Approx. 300
(PE port) 38.4 54.4 H: Approx. 600 168.3
(Lead wire length)
3 3
L-type plug connector (L): VF3 4 30- L 1- 01
02 DIN terminal (D) (Y): VF3 4 30- D
Y 1- 01
02
5 5
Max. 10 179.6
Applicable cable O.D.
81.8
Approx. 300 178.6 ø4.5 to ø7
(Lead wire length)
81.3
Pg 9
84.5
75.5
21.8
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
3 3
M-type plug connector (M): VF3 4 30- M
5
1- 01
02 Conduit terminal (T): VF3 4 30- T
5
1- 01
02
(Lead wire length)
Max. 10 184.4
Approx. 300
Pg 9
78.7 [68.7]
55.5
10
Series VF1000/3000/5000
Dimensions: Series VF5000/Body Ported (mm)
2-position single
G
Grommet (G) (H): VF5120- H 1- 02
03
G: Approx. 300
H: Approx. 600 142.2
(Lead wire length) 103.7
44 28.5
(28.2)
(Distance be
tween ports)
2B
3
24
32
1.2
4A
Manual override
1/4, 3/8
2 x ø4.3 28 36.5
[4(A), 2(B) port]
(For mounting)
- +
36
45
40
22
3EB
16.3
5EA 1P
ø2.3 50.5
(PE port)
100.8
D
L-type plug connector (L): VF5120- L 1- 02
03 DIN terminal (D) (Y): VF5120- Y 1- 02
03
Max. 10 149
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 148.5
(Lead wire length)
Pg9
85
76
22.3
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
Max. 10 151.4
Approx. 300
(Indicator light)
Pg9
89.2 [79.2]
79.2 [69.2]
56
11
Series VF1000/3000/5000
Pilot Operated 5 Port Solenoid Valve
Body Ported/Single Unit
2-position double
G
Grommet (G) (H): VF5220- H 1- 02
03
G: Approx. 300
H: Approx. 600 183.3
(Lead wire length) 106.4
(28.2)
(Distance be
tween ports)
1.2
3
2B
24
32
1.2
4A
Manual override
28 1/4, 3/8
2 x ø4.3 44 [4(A), 2(B) port]
(For mounting)
(Indicator light)
- +
36
45
40
22
3EB
16.3
5EA 1P
0.4
2 x ø2.3
100.6
(PE port)
D
L-type plug connector (L): VF5220- L 1- 02
03 DIN terminal (D) (Y): VF5220- Y 1- 02
03
Max. 10 197
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 196
(Lead wire length)
Pg9
85
76
22.3
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
169 ø4.5 to ø7
(Indicator light)
Pg9
89.2 [79.2]
79.2[69.2]
56
12
Series VF1000/3000/5000
Dimensions: Series VF5000/Body Ported (mm)
1.2
3
2B
24
32
1.2
4A
Manual override
28 1/4, 3/8
2 x ø4.3 [4(A), 2(B) port]
44
(For mounting)
(Indicator light)
- +
36
45
40
22
3 x ø4.3 27
(For mounting) DC without light/surge voltage suppressor
G: Approx. 300
1/4, 3/8 H: Approx. 600 204.7
[1(P), 5(EA), 3(EB) port] (Lead wire length) 92.9
52
0.4
3EB
16.3
5EA 1P
0.4
2 × ø2.3
50.3 69.3
(PE port)
3 3 D
L-type plug connector (L): VF5 4 20- L
5
1- 02
03 DIN terminal (D) (Y): VF5 4 20-
5 Y 1- 02
03
Max. 10 216
98.5
Applicable cable O.D.
Approx. 300 215
ø4.5 to ø7
(Lead wire length)
98
Pg9
85
76
22.3
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
3 3
M-type plug connector (M): VF5 4 20- M
5
1- 02
03 Conduit terminal (T): VF5 4 20-
5
T 1- 02
03
Max. 10 220.8
(Lead wire length)
198.2
Approx. 300
Pg9
89.2 [79.2]
79.2 [69.2]
56
13
Series VF1000/3000/5000
Madeeto
Made to Order
Please contact SMC for detailed dimensions, specifications, and lead times.
Ord r
1 Body Ported Pilot Exhaust Port with Piping Thread (M3) Specification
In this specification, piping to the pilot exhaust port (PE port) is available when the valve is used in an environment where the exhaust from the
pilot valve is not allowable, or intrusion of ambient dust should be prevented.
Combination with low wattage specification is not possible.
VF 3 30 1 X500
Series
Pilot exhaust port (PE port)
1 VF1000 M3 x 0.5
3 VF3000
5 VF5000 Entry is the same as standard products.
The specifications and performance are
Type of actuation the same as those of standard products.
1 2-position single Body model
2 2-position double Symbol VF1000 VF3000 VF5000
3 3-position closed center 2 —
4 3-position exhaust center 3 — —
5 3-position pressure center Note) Not available for the base mounted type.
3EB 3EB
5EA 5EA
1P 1P
L2
L1 L3
3EB
Series L1 L2 L3 L4 L5
5EA VF1000 34.5 4.2 33.4 — —
1P
L2
VF 3 1 X600
Series
1 VF1000
3 VF3000
Entry is the same as standard products.
5 VF5000
Note) Rated voltage: AC type only
Type of actuation
1 2-position single
2 2-position double
3 3-position closed center
4 3-position exhaust center
5 3-position pressure center 14
Pilot Operated 5 Port Solenoid Valve
Base Mounted Series VF3000/5000
Single Unit Note) Only DIN and conduit terminal
RoHS
types are available with AC
mode. Refer to the electrical
entry for details.
How to Order Valve
Base mounted
(VF1000: Not available) VF 3 1 4 0 K T 5 G Z D 1 02
Series
3 VF3000 Type of actuation
Made to Order
5 VF5000 1 2-position single
Nil —
Not available 2 2-position double
TRIAC output specification
with the VF1000. 3 3-position closed center X600 (Refer to page 14.)
4 3-position exhaust center
5 3-position pressure center
Thread type
Body model Nil Rc
F G
Body option
N NPT
0: Pilot valve individual exhaust Pressure specifications T NPTF
Nil Standard 102 psi (0.7 MPa)
K High-pressure type 145 psi (1 MPa) Port size (Sub-plate)
Symbol Port size VF3000 VF5000
PE port EA/EB port Coil specifications
Nil Without sub-plate
VF3000 VF5000 Nil Standard
02 1/4
— T With power saving circuit (DC only)
03 3/8
3: Main/Pilot valve common Note) Be sure to select the power saving circuit
04 1/2 —
exhaust type when it is continuously energized for
long periods of time. (Refer to page 51 for Without the sub-plate, two mounting screws
details.) and a gasket are included.
T type is available with DC mode only. When T is
PE port EA/EB port selected, only Z type of light/surge voltage
Manual override
VF3000 VF5000 suppressor is available. (Note that when the Nil: Non-locking D: Push-turn locking E: Push-turn locking
electrical entry of DIN terminal type without push type slotted type lever type
— connector is selected, only DOS and YOS are
4: Pilot valve base exhaust available.)
Rated voltage
DC AC (50/60 Hz)
PE port 5 24 VDC 1 100 VAC
6 12 VDC 2 200 VAC
VF3000 VF5000 3 110 VAC [115 VAC]
— 4 220 VAC [230 VAC]
7 240 VAC
Light/Surge voltage suppressor
B 24 VAC
Symbol Light/Surge voltage suppressor DC AC
Nil Without light/surge voltage suppressor
Electrical entry
S With surge voltage suppressor — Note)
L-type plug M-type plug DIN DIN Conduit
Grommet (EN175301-803) Z With light/surge voltage suppressor
connector connector terminal terminal terminal R With surge voltage suppressor (Non-polar) —
[IP65 compatible] [IP65 compatible] [IP65 compatible] U With light/surge voltage suppressor (Non-polar) —
Note) S type is not available with AC mode, since a rectifier
prevents surge voltage generation.
In the DIN terminal type, since a light is installed in the con-
nector, DOZ, DOU, YOZ, YOU are not available.
LN: MN:
Without lead wire Without lead wire
G: Lead wire
length 300 mm
H: Lead wire
length 600 mm LN and MN types are with 2 sockets.
DC Refer to page 49 when different length of lead wire for L/M-type plug
Without light/ connector is required.
Refer to page 50 for details on the DIN (EN175301-803) terminal.
surge voltage LO: MO: DO: YO:
Note 1) When using IP65, select the main/pilot valve common exhaust
suppressor Without connector Without connector Without connector Without connector type or pilot valve base exhaust type.
CE DC Note 2) With the same specifications as the DC type, all electrical
compliant AC Note 2) — — — entries for the 24 VAC type are CE marking compliant.
15
Series VF3000/5000
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Single Unit
Specifications
Model VF3000 VF5000
Fluid Air
2-position single/3-position 22 to 102 psi (0.15 to 0.7 MPa)
Operating Standard 2-position double 15 to 102 psi (0.1 to 0.7 MPa)
pressure High- 22 to 145 psi (0.15 to 1.0 MPa)
2-position single/3-position
range pressure
type 2-position double 15 to 145 psi (0.1 to 1.0 MPa)
Ambient and fluid temperature 14 to 144°F (–10 to 50°C) (No freezing)
Max. operating 2-position single/double 10 5
Series VF3000
frequency (Hz) 3-position 3 3
Non-locking push type
Manual override Push-turn locking slotted type
Push-turn locking lever type
16
Series VF3000/5000
Flow-rate Characteristics/Weight
17
Series VF3000/5000
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Single Unit
(EA)5 1 3(EB)
(P)
Strainer
5 4 1 2 3
(EA) (A) (P) (B) (EB)
(EA)5 1 3(EB)
(P)
5 4 1 2 3
(EA) (A) (P) (B) (EB)
Symbol
3-position closed center 3-position closed center/exhaust center/pressure center
(A)4 2(B)
(EA)5 1 3(EB)
(P)
(EA)5 1 3(EB)
(P)
(EA)5 1 3(EB)
(P)
(Drawing shows a closed center type.)
Sub-plate part no.
VF 3 000 71 1
Component Parts
Series Thread type
No. Description Material Note
3 VF3000 Nil Rc
1 Body Aluminum die-casted White 5 VF5000 F G
2 Adapter plate Resin Gray N NPT
3 End plate Resin White Port size T NPTF
4 Piston Resin Symbol Port size VF3000 VF5000
1 1/4
5 Spool valve Aluminum, HNBR
2 3/8
6 Spring Stainless steel
3 1/2 —
Replacement Parts
Part no.
No. Description Note
VF3000 VF5000
7 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 19. Built-in strainer
8 Gasket DXT031-30-11 DXT156-9-8 HNBR
1/4: VF5000-71-1
1/4: VF3000-71-1 Aluminum
9 Sub-plate 3/8: VF5000-71-2
3/8: VF3000-71-2 die-casted
1/2: VF5000-71-3 Caution
Round head combination DXT031-44-1
— — For mounting valve Tightening Torque
screw (1 pc.) (M4 x 39.5, With spring washer)
for Mounting Valve
— Hexagon socket head cap AXT620-32-1
— For mounting valve M4: 10.3 lbf·ft (1.4 N·m)
screw (1 pc.) (M4 x 48, With spring washer)
18
Series VF3000/5000
How to Order Pilot Valve Assembly (With a gasket and two mounting screws)
Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit type), or
vice versa.
Valve model: VF
Select from the below in accordance with the valve used.
5 G Z 1
Grommet or L/M-type
V2 11 5 G Z
Light/Surge voltage suppressor DC AC
Nil Without light/surge voltage suppressor
S With surge voltage suppressor —Note)
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar) —
V211
U With light/surge voltage suppressor (Non-polar) —
Pilot valve assembly
Note) S type is not available with AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.
Caution
When using the surge voltage suppressor type, residual
voltage will remain. Refer to page 51 for details.
Electrical entry
G Grommet (Lead wire length 300 mm)
H Grommet (Lead wire length 600 mm)
L With lead wire
L-type plug
LN connector
Without lead wire
LO Without connector
M With lead wire
M-type plug
MN connector
Without lead wire
MO Without connector
LN and MN types are with 2 sockets.
Refer to page 49 when different length of lead
wire for L/M-type plug connector is required.
DIN or Conduit type
V2 12 5
DIN connector
(Refer to page 50.)
Pressure specifications
Rated voltage
Nil Standard (102 psi (0.7 MPa))
K High-pressure type (145 psi (1 MPa)) DC
5 24 VDC
6 12 VDC
Coil specifications
Nil Standard
AC (50/60 Hz)
1 100 VAC
With power saving circuit
T (DC only) 2 200 VAC
T type is available with DC mode only. 3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
V212 7 240 VAC
Pilot valve assembly B 24 VAC
Caution
For V212 (DIN or Conduit type), the coil specifications and voltage (including light/surge voltage suppressor) cannot be changed by replacing
the pilot valve assembly.
Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.24 lbf·ft (0.32 N·m)
19
Series VF3000/5000
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Single Unit
2-position single
G
Grommet (G) (H): VF3140- H 1-02
03
1/4, 3/8 28 33
[4(A), 2(B) port]
13
22
84.5
50 Manual 36 20
override
1.7
4A 2B
5EA
26.4
35
42
- +
3EB
5EA 1P 3EB
63.5
44.3
PE port 27
22
13
1/4, 3/8 25 25
[1(P), 5(EA), 3(EB) port] 43
81
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
Max. 10 132.2
Approx. 300
Pg9
117.2 [107.2]
107.2 [97.2]
84
20
Series VF3000/5000
Dimensions: Series VF3000/Base Mounted (mm)
2-position double
G
Grommet (G) (H): VF3240- H 1- 02
03
1/4, 3/8 28 33
[4(A), 2(B) port]
13
22
50 Manual 36 20
override
1.7
4A 2B
5EA
26.4
35
42
- +
3EB
5EA 1P 3EB
1.7
(Indicator light) 2 x ø4.3
(For mounting)
73 11.5 Grommet (G) (H)
G: Approx. 300 27
DC without light/surge voltage suppressor
H: Approx. 600 149.9
(Lead wire length) G: Approx. 300
H: Approx. 600 152.3
(Lead wire length)
73
44.3
2 x PE port
27
22
13
28.2
1/4, 3/8 25 25
[1(P), 5(EA), 3(EB) port] 43
81
33.3
33.8
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
Pg9
117.2 [107.2]
107.2 [97.2]
84
36.2
24.9 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
21
Series VF3000/5000
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Single Unit
13
22
50 Manual 36 20
override
1.7
4A 2B
5EA
26.4
35
42
- +
3EB
5EA 1P 3EB
1.7
(Indicator light) 2 x ø4.3
(For mounting)
84.5 4.5 Grommet (G) (H)
DC without light/surge voltage suppressor
G: Approx. 300 43
H: Approx. 600 165.9
G: Approx. 300
(Lead wire length) H: Approx. 600 168.3
(Lead wire length)
73
44.3
2 x PE port
27
22
13
3 3
L-type plug connector (L): VF3 440- L
5
1- 02
03 DIN terminal (D) (Y): VF3 440-
5
D
Y 1-02
03
Max. 10 179.6
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 178.6
(Lead wire length)
Pg9
113
104
50.3
49.3
49.8
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
3 3
M-type plug connector (M): VF3 4 40- M
5
1- 02
03 Conduit terminal (T): VF3 4 40- T
5
1- 02
03
(Lead wire length)
Max. 10 184.4
Approx. 300
Pg9
117.2 [107.2]
107.2 [97.2]
84
40.9 52.2
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
22
Series VF3000/5000
Dimensions: Series VF5000/Base Mounted (mm)
2-position single
G 02
Grommet (G) (H): VF5144- H 1- 03
04
1/4, 3/8, 1/2
27 36
(15.5)
[4(A), 2(B) port]
(31) (40)
14
20.5
(24.5)
(Indicator light)
51 2 x ø5.3 (2 x ø6.5) 82 5
(55) (For mounting) (87) (6.5)
Manual override 4A 2B
(45)
(58)
42
52
- +
4A
2B
PE
1.2
6.5
(78)
74
14
(49.3)
45.3
(32.5)
28.5
30 30
(31) (31) 1/4, 3/8, 1/2
50 [1(P), 5(EA), 3(EB) port]
(54)
92 4.5
The dimensions in ( ) are for 1/2 piping port size. (100) (0.5)
02 D 02
L-type plug connector (L): VF5144- L 1- 03 DIN terminal (D) (Y): VF5144- Y 1- 03
04 04
Max. 10 149
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 148.5
(Lead wire length)
Pg 9
(118)
114
(109)
105
(55.3)
51.3
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
02 02
M-type plug connector (M): VF5144- M 1- 03 Conduit terminal (T): VF5144- T 1- 03
04 04
(Lead wire length)
Max. 10 151.4
Approx. 300
108.2 [98.2]
(89)
85
23
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Single Unit Series VF3000/5000
Dimensions: Series VF5000/Base Mounted (mm)
2-position double
G 02
Grommet (G) (H): VF5244- H 1- 03
04
1/4, 3/8, 1/2
27 36
(15.5)
[4(A), 2(B) port]
(31) (40)
14
(24.5)
20.5
(Indicator light)
2 x ø5.3 (2 x ø6.5)
51 82 5
(For mounting)
(55) (87) (6.5)
Manual override 4A 2B
1.2
(45)
(58)
42
52
- +
4A
2B
PE
1.2
6.5
5EA 1P 3EB
2 x M5 x 0.8
22.5 99.2 7.2
(PE port)
(103.2) (3.2)
Grommet (G) (H)
(26.5)
45.6
DC without light/surge voltage suppressor
G: Approx. 300 G: Approx. 300
H: Approx. 600 183.3 (41.6)
H: Approx. 600 185.7
(Lead wire length) (Lead wire length)
(78)
74
(49.3)
45.3
(32.5)
46.9
28.5
(42.9)
30 30
14
(15.5)
(31) (31)
50
1/4, 3/8, 1/2
(54)
92 [1(P), 5(EA), 3(EB) port]
The dimensions in ( ) are for 1/2 piping port size. (100)
02 D 02
L-type plug connector (L): VF5244- L 1- 03 DIN terminal (D) (Y): VF5244- Y 1- 03
04 04
Max. 10 197
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 196
(Lead wire length)
Pg 9
(118)
114
(109)
(55.3)
105
51.3
52
(48)
52.5
(48.5)
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
02 02
M-type plug connector (M): VF5244- M 1-03 Conduit terminal (T): VF5244- T 1- 03
04 04
Max. 10 201.8
(Lead wire length)
Approx. 300
(112.2 [102.2])
108.2 [98.2]
(89)
85
54.9
43.6 (50.9)
(39.6) Unless otherwise indicated, dimensions are the same as Grommet (G).
Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: Without indicator light
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
24
Series VF3000/5000
Dimensions: Series VF5000/Base Mounted (mm)
(15.5)
[4(A), 2(B) port]
(31) (40)
14
20.5
(24.5)
(Indicator light)
51 2 x ø5.3 (2 x ø6.5) 82 5
(55) (For mounting) (87) (6.5)
1.2
Manual override 4A 2B
(45)
(58)
42
52
- +
4A
2B
PE
1.2
6.5
5EA 1P 3EB
2 x M5 x 0.8
99.2 26.2
22.5 (PE port) Grommet (G) (H)
(26.5) (103.2) (22.2) DC without light/surge voltage suppressor
G: Approx. 300 64.6
G: Approx. 300
H: Approx. 600 202.3 (60.6)
H: Approx. 600 204.7
(Lead wire length)
(Lead wire length)
(78)
74
(49.3)
45.3
(32.5)
65.9
28.5
(61.9)
30 30
14
(15.5)
(31) (31)
50
(54) 1/4, 3/8, 1/2
92
[1(P), 5(EA), 3(EB) port]
The dimensions in ( ) are for 1/2 piping port size. (100)
3 02 3 D 02
L-type plug connector (L): VF5 4 44- L 1- 03 DIN terminal (D) (Y): VF5 4 44- Y 1- 03
5 04 5 04
Max. 10 216
Applicable cable O.D.
Approx. 300 215 ø4.5 to ø7
(Lead wire length)
Pg9
(55.3)
(118)
51.3
114
(109)
105
71
(67)
71.5
(67.5)
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
3 02 3 02
M-type plug connector (M): VF5 4 44- M 1- 03 Conduit terminal (T): VF5 4 44- T 1- 03
5 04 5 04
(Lead wire length)
Approx. 300
(112.2 [102.2])
108.2 [98.2]
(89)
85
73.9
62.6
(69.9)
(58.6)
Unless otherwise indicated, dimensions are the same as Grommet (G).
Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: Without indicator light
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
25
Body Ported
Low Wattage Specification
Base Mounted
Series VF1000/3000
Single Unit RoHS
VF 3 1 3 0 Y 5 G 1 02
Series Bracket
1 VF1000 Nil Without bracket
3 VF3000 With bracket
Available with
F the VF1120, VF1220
Type of actuation and VF3130 only.
1 2-position single
2 2-position double Thread type
3 3-position closed center Nil Rc, M5
4 3-position exhaust center F G
5 3-position pressure center N NPT
Only 1 and 2 are available with T NPTF
the VF1000.
<Body ported> A, B port size
Mountable manifold M5 M5 x 0.8 (VF1000)
Body model 30 31 40 01 1/8 (VF1000, VF3000)
2 VF1000 Body ported — — — 02 1/4 (VF3000)
VF1000 Base mounted Note 1) Note 1) —
3 — —
<Base mounted> Sub-plate port size
VF3000 Body ported Note 1)
Nil Without sub-plate
4 VF3000 Base mounted — — Note 2)
02 Port size: 1/4
Note 1) Refer to page 30.
03 Port size: 3/8
Note 2) Refer to page 41.
Version symbol
Body option Manual override
0: Pilot valve individual exhaust
Nil Non-locking push type
D Push-turn locking slotted type
E Push-turn locking lever type
1 100 VAC
−?
2
-+
200 VAC
3 110 VAC
4 220 VAC H: Lead wire LN: Without LO: Without MO: Without DO: Without connector YO: Without connector
length 600 mm lead wire connector connector
5 24 VDC
6 12 VDC
−? -+
CE DC
compliant AC — — —
LN and MN types are with 2 sockets.
Y type DIN terminal complies with EN-175301-803C (former DIN 43650C). Refer to page 50 for
details.
When using IP65, select the main/pilot valve common exhaust type. (Except VF1000)
26
Series VF1000/3000
Specifications
Model VF1000 VF3000
Fluid Air
Internal pilot operating 2-position single/3-position 22 to 102 psi (0.15 to 0.7 MPa)
pressure range 2-position double 15 to 102 psi (0.1 to 0.7 MPa)
Ambient and fluid temperature 14 to 122°F (–10 to 50°C) (No freezing)
Max. operating 2-position single/double 5 5
frequency (Hz) 3-position 3 3
Non-locking push type
Manual override Push-turn locking slotted type
Push-turn locking lever type
Pilot exhaust type Main/Pilot valve common exhaust
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 150/30
Enclosure Dustproof (IP65 for DIN terminal)
Based on IEC 60529.
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to
the main valve and armature in both energized and de-energized states every once for
each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed
at both energized and de-energized states in the axial direction and at the right angles to
the main valve and armature. (Values at the initial period)
Solenoid Specifications
Response Time
27
Series VF1000/3000
Low Wattage Specification
Body Ported/Base Mounted/Single Unit
Dimensions (mm)
VF1000
(D
ist
a
A, B port size: M5 x 0.8
( 1 e tw
nc
6. ee
eb
6) n p
(Di ween
bet
11 e
sta
1/8"
nc ports
.7
o
11.5 12 M5 x 0.8
rts
[4(A), 2(B) port]
)
[4(A), 2(B) port] 6 14.8
Manual override
)
2B 2B
26.4
12
20
10
4A 4A
(Dis (13
tan .4
ce
(Indicator light) bet )
wee
np
orts
)
(10)
3EB
(E type)
6
(AC)
-
38.6
42
(45)
(55)
35
35
19.6
17.5
14.5
5EA
M5 x 0.8 12 11.8
[5(EA), 3(EB) port] 2 x ø5.5 (16)
30 (For mounting)
(26)
1P
1
ø2.3
17.8 M5 x 0.8, 1/8"
(PE port)
42.7 [1(P) port]
L-type plug connector (L) M-type plug connector (M) DIN terminal (D) (Y)
Max. 10 52.1 30
Applicable cable O.D. Pg7
30.5 ø3.5 to ø7
64.3
56.8
(AC)
53.1
46.1
(AC)
42
35
19.6
45.3 35.5
47.5 30 37.7 30
(AC) (AC)
28
Series VF1000/3000
Dimensions (mm)
VF3000
1/8", 1/4"
[4(A), 2(B) port]
10 25.5 2 x ø4.3
Manual override (For mounting)
4A
26.4
20
2B
23 19
G: Approx. 300 66.2 (1.6)
H: Approx. 600 90.9 (6)
(Lead wire length) (AC: 93.1)
(Indicator light)
55.5
(10)
(E type)
-
(AC)
38.6
42
(45)
(55)
31.5
35
35
19.6
17.5
7
2 x ø4.2 20.5 20.3
(For mounting) 2 x ø5.5 (16)
(For mounting)
(26)
1/8", 1/4"
[1(P) port]
(18.4)
1/8" (Distan (18
[5(EA), 3(EB) port] ce betw .4)
een port
s)
1P 3EB
8
1
5EA
ø2.3 36 12.5
(PE port) 30.5
68.2
L-type plug connector (L) M-type plug connector (M) DIN terminal (D) (Y)
Max. 10 52.1 55.5
Applicable cable O.D. Pg7
30.5 ø3.5 to ø7
64.3
56.8
(AC)
53.1
46.1
(AC)
42
35
19.6
45.3 35.5
47.5 55.5 37.7 55.5
(AC) (AC)
29
Pilot Operated 5 Port Solenoid Valve
VF1000/3000/5000
Body Ported
Series
Manifold Note) Only DIN and conduit terminal types are
available with AC mode.
How to Order Manifold Refer to the electrical entry for details.
VV5F 1 30 04 1 VV5F1 31 04 3
Series Thread type Stations Thread type
1 VF1000
Stations Nil Rc
3 VF3000 02 2 stations Nil Rc
02 2 stations 00F G 00F G
5 VF5000 Manifold model 00N NPT 20 20 stations 00N NPT
Symbol P, R port size VF1000 VF3000 VF5000 20 20 stations 00T NPTF 00T NPTF
1/8 — — Up to 10 stations for
30
1/4 — — VV5F5-20, and up
Manifold model
— — to 15 stations for Symbol P, R port size EA, EB port size
20 3/8
VV5F5-21. 31 1/8 M5
21 1/2 — —
The A and B ports are made on the top.
How to Order Valve (With a gasket and two mounting screws)
For low wattage specification, refer to “How to Order Valve” on page 26.
VF 3 1 3 0 5 G 1 01
Series
1 VF1000 Type of actuation Made to order
Coil specifications Refer to page 14 for details.
3 VF3000 1 2-position single Nil Standard Combination with low wattage specification
5 VF5000 2 2-position double T With power saving circuit (DC only) is not possible.
3 3-position closed center Thread type
Note) Be sure to select the power
4 3-position exhaust center saving circuit type when it is
A, B port size Nil Rc
5 3-position pressure center continuously energized for Symbol Port size VF1000 VF3000 VF5000 F G
long periods of time. (Refer M5 M5 x 0.8 — —
Only 1 and 2 are available with the VF1000. to page 51 for details.)
N NPT
T type is available with DC mode 01 1/8 — T NPTF
only. When T is selected, only Z 02 1/4 — M5 is available
Body option type of light/surge voltage 03 3/8 — — with Nil only.
0: Pilot valve individual exhaust 3: Main/Pilot valve common exhaust suppressor is available. (Note
that when the electrical entry of Manual override
DIN terminal type without Light/Surge voltage suppressor Nil: Non-locking
connector is selected, only DOS
and YOS are available.) Symbol Light/Surge voltage suppressor DC AC push type
Nil Without light/surge voltage suppressor
PE port EA/EB port PE port EA/EB port Pressure specifications Note)
—
S With surge voltage suppressor
VF1000 VF3000 VF5000 VF1000 VF3000 VF5000 Nil Standard (102 psi (0.7 MPa))
Z With light/surge voltage suppressor
K High-pressure type (145 psi (1 MPa))
R With surge voltage suppressor (Non-polar) —
Rated voltage U With light/surge voltage suppressor (Non-polar) —
Body model
DC AC (50/60 Hz) Note) S type is not available with AC mode, since a rectifier
Symbol VF1000 VF3000 VF5000
5 24 VDC 1 100 VAC 4 220 VAC [230 VAC] prevents surge voltage generation. D: Push-turn locking
2 — —
6 12 VDC 2 200 VAC 7 240 VAC In the DIN terminal type, since a light is installed in the slotted type
3 Note) — connector, DOZ, DOU, YOZ, YOU are not available.
3 110 VAC [115 VAC] B 24 VAC
Note) Manifold only.
Electrical entry
DIN DIN (EN175301-803) Conduit
Grommet L-type plug connector M-type plug connector
terminal terminal terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible]
E: Push-turn locking
lever type
G: Lead wire G: Lead wire L: With lead wire LN: M: With lead wire MN:
length 300 mm length 300 mm (length 300 mm) Without lead (length 300 mm) Without lead
H: Lead wire H: Lead wire wire wire D: With connector Y: With connector T: Conduit
length 600 mm length 600 mm terminal
DC
Without light/
surge voltage
suppressor LO: MO:
Without connector Without connector DO: Without connector YO: Without connector
CE DC
Caution
compliant ACNote 2) — — — When using the surge
LN and MN types are with 2 sockets. Refer to page 49 when different length of lead wire for L/M-type plug connector is required.
voltage suppressor
Refer to page 50 for details on the DIN (EN175301-803) terminal. type, residual voltage
Note 1) When using IP65, select the main/pilot valve common exhaust type. will remain. Refer to
Note 2) With the same specifications as the DC type, all electrical entries for the 24 VAC type are CE marking compliant. page 51 for details.
30
Series VF1000/3000/5000
Manifold Specifications
VV5F5-20
VV5F1-31
4(A), 2(B) port
Manifold 4(A), 2(B) port
1(P) port 1/4, 3/8
base model 1/8 5(R), 3(R) port
1/8
5/3(R) port 5(R), 3(R) port 1/2
1/8 1/4
1(P) port
3/8
Manifold base
Weight: W [g] W = 29n + 21 W = 51n + 35 W = 63n + 64 W = 97n + 80 W = 139n + 550
Stations: n
Note) Supply pressure to 1(P) ports and exhaust pressure from R ports on both sides for 10 stations or more (5 stations or more for the VF5000).
Example (VV5F3-30)
Closed center (24 VDC) Double solenoid (24 VDC)
VF3330-5GZ1-02 (1 set) VF3230-5GZ1-02 (1 set)
3
2
1 Ds
ide
VV5F3-30-051 ······················· 1 set (Type 30, 5-station manifold base part no.)
VF3130-5GZ1-02 ·················· 3 sets (Single solenoid part no.)
VF3230-5GZ1-02 ·················· 1 set (Double solenoid part no.)
VF3330-5GZ1-02 ·················· 1 set (Closed center part no.)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
31
Pilot Operated 5 Port Solenoid Valve
Body Ported/Manifold Series VF1000/3000/5000
Manifold Options
For body ported Mounting screw, gasket part no.
Blanking plate assembly
Gasket
Series Blanking plate assembly part no. Series Valve mounting screw (1 pc.) Gasket
VF1000 DXT144-13-3A VF1000 Round head combination screw DXT144-12-2
VF3000 DXT031-38-5A DXT031-44-1
VF3000 (M4 x 39.5, With spring washer) DXT155-25-7
VF5000 VF5000-70-1A
Hexagon socket head cap screw
VF5000 AXT620-32-1 DXT156-9-6
(M4 x 48, With spring washer)
Individual EXH spacer assembly
Caution
Tightening Torque for Mounting Screw
M4: 1.03 lbf·ft (1.4 N·m)
Warning
When mounting a valve or spacer on the manifold base or sub-plate,
etc., the mounting orientation is already decided. If mounted in a
wrong direction, the equipment to be connected may result in a
malfunction. Refer to the dimensions for mounting.
EXH port
EXH port
VF 3 000 75 1 A
Series Thread type
Symbol Series Port size Nil Rc
3 VF3000 1/8 F G
5 VF5000 1/4 N NPT
T NPTF
32
Series VF1000/3000/5000
Dimensions: Series VF1000 (mm)
10
17.8
6
124.4
126.8
4A
R
R
4A
4A
4A
4A
4A
R
21
35
2B
2B
2B
2B
2B
2B
P
P
11.5
62.2
63.4
1/8
23.8
P = 27.5 23.5
G: Approx. 300
H: Approx. 600
G: Approx. 300
H: Approx. 600
(Station n) (Station 1)
- + - + - + - + - +
65
42
137.1
20
L2 64.5 92 119.5 147 174.5 202 229.5 257 284.5 312 339.5 367 394.5
n 15 16 17 18 19 20
L
L1 432 459.5 487 514.5 542 569.5
L2 422 449.5 477 504.5 532 559.5 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
(Indicator light)
120.3
110.1
138.1
142.9
60.1
55
71.5
69
96 99.2 [89.2]
105 109.2 [99.2]
33
Pilot Operated 5 Port Solenoid Valve
Body Ported/Manifold Series VF1000/3000/5000
Dimensions: Series VF1000 (mm)
G: Approx. 300
H: Approx. 600
G: Approx. 300
H: Approx. 600
L1
M5 M5 x 0.8
5 L2 41.3
Manual [4(A), 2(B) port]
override
7.5
1/8
23.8
[1(P) port]
63.4
62.2
11.5
6
124.4
126.8
2B
2B
2B
2B
2B
2B
P
P
P
34
4A
4A
4A
4A
4A
4A
9.3
10
17
17.8
23.8
ø8.2
2 x ø5.5 (Not used.)
1.7 (For mounting)
(Pitch) PE port
23.5 P = 27.5 1/8
[4(A), 2(B) port]
(Station 1) (Station n)
(Indicator light)
L-type plug connector (L)
Approx. 300
70
47
25
EA EB EA EB 47.3
M5 x 0.8
[5(EA), 3(EB) port]
11 (Pitch)
18 P = 27.5
68.5
L: Dimensions
137.1
n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
L1 74.5 102 129.5 157 184.5 212 239.5 267 294.5 322 349.5 377 404.5
L2 64.5 92 119.5 147 174.5 202 229.5 257 284.5 312 339.5 367 394.5
n 15 16 17 18 19 20
L
L1 432 459.5 487 514.5 542 569.5
Unless otherwise indicated, dimensions are the same as
L2 422 449.5 477 504.5 532 559.5 Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
Applicable cable Applicable cable
O.D. O.D.
ø4.5 to ø7 ø4.5 to ø7
110 114.2 [104.2]
Approx. 300 81
Max. 10
Max. 10
71.5
69
(Indicator light)
138.1
142.9
Unless otherwise indicated, dimensions are the same as Unless otherwise indicated, dimensions are the same as [ ]: Without indicator light
Grommet (G). Grommet (G). Unless otherwise indicated, dimensions are the same as
Grommet (G).
34
Series VF1000/3000/5000
Dimensions: Series VF3000 (mm)
.8) ce ts)
(23 stan por
1/8, 1/4
17.5
n
[4(A), 2(B) port]
( twee
11.5
be
D i
1
52.5
36.5
32.5
R
165.9
168.3
2B
2B
2B
2B
2B
149.9
152.3
46
65
P
P
36.5
24
23
4A
4A
4A
4A
4A
R
R
76.2
4 x ø5.5 75 1/4
(For mounting) [1(P), 5(R), 3(R) port]
1.7 PE port
Manual 43.8
(Pitch)
G: Approx. 300
H: Approx. 600
override
G: Approx. 300
H: Approx. 600
P = 27.5 28
(Station n) (Station 1)
- + - + - + - + - +
72.5
49.5
27
178.6
162.6
81.3
L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L 49.8
L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5 (Lead wire length)
L2
Approx. 300
71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5
n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6
161.8
179.6
184.4
135.6
145.8
163.6
168.4
(Indicator light)
67.8
72.9
81.8
84.2
Max. 10
35
Pilot Operated 5 Port Solenoid Valve
Body Ported/Manifold Series VF1000/3000/5000
Dimensions: Series VF3000 (mm)
(23 tanc n po
(D twee
.8)
be
is
17.5
e rts)
1 11.5
52.5
36.5
32.5
R
165.9
168.3
2B
2B
2B
2B
2B
149.9
152.3
46
65
P
P
36.5
23
24
4A
4A
4A
4A
4A
R
R
76.2
75
4 x ø5.5 1/4
(For mounting) [1(P), 5(R), 3(R) port]
1.7 PE port
(Lead wire length)
59.8
G: Approx. 300
H: Approx. 600
H: Approx. 600
G: Approx. 300
override P = 27.5 28
(Station n) (Station 1)
L-type plug connector (L)
(Indicator light)
(VF3000-75-1A)
88.5
65.5
178.6
27
162.6
1/8 5
(EXH port)
81.3
L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5 65.8
(Lead wire length)
L2 71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5
Approx. 300
n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6
161.8
179.6
184.4
135.6
145.8
163.6
168.4
(Indicator light)
67.8
72.9
81.8
84.2
rts)
53.2
50.5
een po
30
28
R
202.3
204.7
183.3
185.7
2B
2B
2B
2B
2B
60
83
P
ce betw
4A
4A
4A
4A
4A
53.2
91.7
92.9
(Distan
3/8
(30.4)
[1(P), 5(R), 3(R) port]
PE port
4 x ø7
G: Approx. 300
H: Approx. 600
1.2
(For mounting) 47.3
(Pitch)
(Lead wire
P = 33 30 Manual override
length)
(Station n) (Station 1)
L-type plug connector (L)
(Indicator light)
- + - + - + - + - +
76
53
29.5
215
196
98
Approx. 300
L: Dimensions 53.3
(Lead wire
n: Stations
n
length)
L 2 3 4 5 6 7 8 9 10
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5
198.2
220.8
216
179.2
201.8
197
(Indicator light)
84.5
89.6
100.9
98.5
Max. 10
rts)
53.2
50.5
30
een po
28
R
202.3
204.7
183.3
185.7
2B
2B
2B
2B
2B
60
83
P
ce betw
4A
4A
4A
4A
4A
53.2
91.7
92.9
(Distan
(30.4)
4 x ø7
G: Approx. 300
H: Approx. 600
1.2 PE port
(Pitch) (For mounting) 73.8
(Lead wire
P = 33 30 Manual override 3/8
length)
[1(P), 5(R), 3(R) port]
(Station n) (Station 1)
L-type plug connector (L)
(Indicator light)
Individual EXH
spacer - + - + - + - + - +
(VF5000-75-1A)
102.5
R R R R R
79.5
43.5
215
29.5
196
1/4
EXH port
98
Approx. 300
L: Dimensions
(Lead wire
79.8
n: Stations length)
n 2 3 4 5 6 7 8 9 10
L
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5
198.2
220.8
216
179.2
201.8
197
(Indicator light)
84.5
89.6
100.9
98.5
133.5
Max. 10
136.7 [126.7]
cable O.D.
142.5 146.7 [136.7]
ø4.5 to ø7
Applicable cable O.D.
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Unless otherwise indicated, dimensions are the same as Unless otherwise indicated, dimensions are the same as
Grommet (G). Grommet (G). Grommet (G).
38
Series VF1000/3000/5000
Dimensions: Series VF5000 (mm)
20
15
3
R
72.2
rts)
53.2
een po
202.3
204.7
183.3
185.7
2B
2B
2B
2B
2B
110
125
28
68
P
P
4A
4A
4A
4A
4A
ce betw
53.2
91.7
92.9
n
R
ta
(34.4)
(Dis
4 x ø9
G: Approx. 300
H: Approx. 600
1/4, 3/8 PE port
1.2 (For mounting) 49.8
[4(A), 2(B) port]
(Lead wire
Manual override 1/2
(Pitch)
length)
[1(P), 5(R), 3(R) port]
P = 33 30
(Indicator light)
- + - + - + - + - +
R
78.5
55.5
215
35
196
P
2.5
98
R
Approx. 300
55.8
L: Dimensions
(Lead wire
n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14 15
length)
L
L1 163 196 229 262 295 328 361 394 427 460 493 526 559 592
L2 128 161 194 227 260 293 326 359 392 425 458 491 524 557 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5
R
198.2
220.8
216
179.2
201.8
197
P
(Indicator light)
84.5
89.6
100.9
98.5
R
Max. 10
20
15
3
R
72.2
rts)
53.2
een po
202.3
204.7
183.3
185.7
2B
2B
2B
2B
2B
110
125
28
68
P
P
4A
4A
4A
4A
4A
ce betw
53.2
91.7
92.9
(Distan
R
(34.4)
4 x ø9
G: Approx. 300
H: Approx. 600
1/4, 3/8 PE port
(For mounting) 76.3
[4(A), 2(B) port] 1.2
(Lead wire
Manual override 1/2
length)
(Pitch) [1(P), 5(R), 3(R) port]
P = 33 30
(Indicator light)
Individual EXH
spacer
- + - + - + - + - +
(VF5000-75-1A)
R
105
R R R R R
215
82
196
P
46
35
1/4
2.5
98
R
EXH port
Approx. 300
82.3
L: Dimensions
(Lead wire
n: Stations
n
length)
L 2 3 4 5 6 7 8 9 10 11 12 13 14 15
L1 163 196 229 262 295 328 361 394 427 460 493 526 559 592
L2 128 161 194 227 260 293 326 359 392 425 458 491 524 557 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5
R
198.2
220.8
216
179.2
201.8
197
P
(Indicator light)
84.5
89.6
100.9
98.5
R
Max. 10
VF 3 1 4 0 5 G 1
Made to Order
Series Refer to page 14 for details.
3 VF3000 Type of actuation Combination with low wattage specification
5 VF5000 is not possible.
1 2-position single
Not available 2 2-position double
Manual override
with the VF1000. Nil: Non-locking D: Push-turn locking E: Push-turn locking
3 3-position closed center
push type slotted type lever type
4 3-position exhaust center
5 3-position pressure center
Body model
Body option
0: Pilot valve individual exhaust
Pressure specifications
Nil Standard (102 psi (0.7 MPa)) Light/Surge voltage suppressor
K High-pressure type (145 psi (1 MPa))
Symbol Light/Surge voltage suppressor DC AC
PE port EA/EB port Nil Without light/surge voltage suppressor
VF3000 VF5000 S With surge voltage suppressor Note)
—
— Rated voltage Z With light/surge voltage suppressor
3: Main/Pilot valve common R With surge voltage suppressor (Non-polar) —
exhaust DC AC (50/60 Hz)
U With light/surge voltage suppressor (Non-polar) —
5 24 VDC 1 100 VAC Note) S type is not available with AC mode, since a rectifier prevents surge
6 12 VDC 2 200 VAC voltage generation.
PE port EA/EB port 3 110 VAC [115 VAC] In the DIN terminal type, since a light is installed in the connector, DOZ, DOU,
4 220 VAC [230 VAC] YOZ, YOU are not available.
VF3000 VF5000
— 7 240 VAC
B 24 VAC
Caution
4: Pilot valve base exhaust When using the surge voltage suppressor type, residual
voltage will remain. Refer to page 51 for details.
Electrical entry
PE port DIN DIN (EN175301-803) Conduit
Grommet L-type plug connector M-type plug connector
terminal terminal terminal
VF3000 VF5000 [IP65 compatible] [IP65 compatible] [IP65 compatible]
—
Coil specifications
Nil Standard
T With power saving circuit (DC only)
G: Lead wire G: Lead wire L: With lead wire LN: M: With lead wire MN:
Note) Be sure to select the power saving circuit type length 300 mm length 300 mm (length 300 mm) Without lead (length 300 mm) Without lead
when it is continuously energized for long
H: Lead wire H: Lead wire wire wire D: With connector Y: With connector T: Conduit terminal
periods of time.
(Refer to page 51 for details.)
length 600 mm length 600 mm
T type is available with DC mode only. When T is DC
selected, only Z type of light/surge voltage Without light/
suppressor is available. (Note that when the surge voltage
electrical entry of DIN terminal type without suppressor
connector is selected, only LO: MO:
DOS and YOS are available.) Without connector Without connector DO: Without connector YO: Without connector
CE DC
compliant ACNote 2) — — —
LN and MN types are with 2 sockets. Refer to page 49 when different length of lead wire for L/M-type plug connector is required.
Refer to page 50 for details on the DIN (EN175301-803) terminal.
Note 1) When using IP65, select the main/pilot valve common exhaust or pilot valve base exhaust type.
Note 2) With the same specifications as the DC type, all electrical entries for the 24 VAC type are CE marking compliant.
41
Series VF3000/5000
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Manifold
Manifold Specifications
VV5F3-40
Common VF3 40 2 to 20
VF3000 EXH VF3 43 stations
W = 110n + 116
1(P) port
1/4
VV5F5-40 PE port
M5 x 0.8
Common 2 to 10
VF5000 EXH
VF5 44 stations
W = 161n + 128
1(P) port
3/8
4(A), 2(B) port
1/4
Note) Supply pressure to 1(P) ports and exhaust pressure from R ports on both sides for 10 stations or more (5 stations or more for the VF5000).
Example (VV5F3-40)
3
2
1 Ds
ide
VV5F3-40-052-02 ············· 1 set (Type 40, 5-station manifold base part no.)
VF3140-5GZ1 ·················· 3 sets (Single solenoid part no.)
VF3240-5GZ1 ·················· 1 set (Double solenoid part no.)
VF3340-5GZ1 ·················· 1 set (Closed center part no.)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
• The valve arrangement is numbered as the 1st station from D side.
• Under the manifold base part number, state the valves to be mounted in order from the 1st station as shown in
the figure above. If the arrangement becomes complicated, specify on the manifold specification sheet.
42
Series VF3000/5000
Manifold Options
For base mounted Mounting screw, gasket part no.
Blanking plate assembly
Gasket
Series Blanking plate assembly part no. Series Valve mounting screw (1 pc.) Gasket
VF3000 DXT031-38-5A Round head combination screw
VF5000 VF5000-70-2A VF3000 DXT031-44-1 DXT031-30-11
(M4 x 39.5, With spring washer)
Hexagon socket head cap screw
Individual EXH spacer assembly VF5000 AXT620-32-1 DXT156-9-8
(M4 x 48, With spring washer)
Caution
Tightening Torque for Mounting Screw
M4: 1.03 lbf·ft (1.4 N·m)
Warning
When mounting a valve or spacer on the manifold base or sub-plate, etc.,
the mounting orientation is already decided. If mounted in a wrong
direction, the equipment to be connected may result in a malfunction.
Refer to the dimensions for mounting.
EXH port
EXH port
VF 3 000 75 2 A
Series Thread type
Symbol Series Port size Nil Rc
3 VF3000 1/8 F G
5 VF5000 1/4 N NPT
T NPTF
43
Series VF3000/5000
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Manifold
s)
port
0.5
ween
52.5
t
36.5
(23 nce be
33
165.9
168.3
R
R
23 23
149.9
152.3
66
P
P
ta
36.5
(Dis
8
24
R
R
.
76.2
75
1/4
[1 (P), 5 (R), 3 (R) port]
G: Approx. 300
H: Approx. 600
(Station n) (Station 1)
(Indicator light)
- + - + - + - + - +
75.5
52.5
30
ø2.2
(PE port)
1/4
L-type plug connector (L)
[4(A), 2(B) port]
(29.
(Dis
7)
tanc
A A
28
B B
e be
twe
178.6
162.6
10
en
(Pitch)
port
P = 27.5 23
s)
81.3
L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5
L2
Approx. 300
71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5 52.8
(Lead wire
length)
n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6
161.8
179.6
184.4
135.6
145.8
163.6
168.4
(Indicator light)
67.8
72.9
81.8
84.2
44
Series VF3000/5000
Dimensions: Series VF3000 (mm)
Type 40/VV5F3-40- 2-02 : When the individual EXH spacer (VF3000-75-2A) is mounted.
Grommet (G) (H) Grommet (G) (H)
L1 DC without light/
L2 6 surge voltage suppressor
19
)
orts
13
en p
0.5
twe
52.5
e
36.5 36.5
b
33
165.9
168.3
R
R
23 23
e
149.9
152.3
tanc
66
P
P
8)
(Dis
.
24
R
3
R
2
76.2
(
75
1/4
[1(P), 5(R), 3(R) port]
G: Approx. 300
H: Approx. 600
(Station n) (Station 1)
(Indicator light)
- + - + - + - + - +
Individual EXH spacer
(VF3000-75-2A)
91.5
68.5
1/8 5
(EXH port)
ø2.2
(PE port) L-type plug connector (L)
1/4
[4(A), 2(B) port]
(29.
(Dis
7)
tanc
A A
28
B B
e be
178.6
twe
162.6
10
en
(Pitch)
port
P = 27.5 23
81.3
s)
L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5
L2
Approx. 300
71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5 68.8
(Lead wire
length)
n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6
161.8
179.6
184.4
135.6
145.8
163.6
168.4
(Indicator light)
67.8
72.9
81.8
84.2
Max. 10
125.7 [115.7]
cable O.D.
131.5
ø4.5 to ø7 135.7 [125.7]
Applicable cable O.D.
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Unless otherwise indicated, dimensions are the same as Unless otherwise indicated, dimensions are the same as
Grommet (G). Grommet (G). Grommet (G).
45
Series VF3000/5000
Pilot Operated 5 Port Solenoid Valve
Base Mounted/Manifold
28
20.5
s)
ort
np
13
ee
tw
be
72.2
7) nce
53.2
50.5
( ist a
PE
PE
)
R
R
202.3
204.7
(D
rt
183.3
185.7
1
np
55
71
79
P
P
etwee
1.3
53.2
27.5
R
PE
PE
nce b
91.7
92.9
3/8
(Dista
)
(27.3
[1(P), 5(R), 3(R) port]
M5 x 0.8
4 x ø7 (PE port)
1.2
(Pitch) (For mounting) 49.3
G: Approx. 300
H: Approx. 600
Manual override
(Station n) (Station 1)
(Indicator light)
- + - + - + - + - +
L-type plug connector (L)
78
55
32.5
PE
215
1/4
196
[4(A), 2(B) port]
PE
98
A A
24
B B
Approx. 300
55.3
L: Dimensions
(Lead wire
n: Stations
(Pitch) n
length)
L 2 3 4 5 6 7 8 9 10
P = 33 30
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5
PE
PE
PE
198.2
220.8
216
179.2
201.8
197
PE
PE
PE
(Indicator light)
84.5
89.6
100.9
98.5
Applicable
Max. 10
46
Series VF3000/5000
Dimensions: Series VF5000 (mm)
Type 40/VV5F5-40- 2-02 : When the individual EXH spacer (VF5000-75-2A) is mounted.
Grommet (G) Grommet (G) (H)
DC without light/
L1 surge voltage suppressor
L2 6.5
por
ts)
een
w
28 bet
ce
ti an
20.5 s
(D 7)
13 (1
72.2
53.2
50.5
s)
PE
PE
n port
R
204.7
202.3
185.7
183.3
55
71
79
etwee
P
P
1.3
53.2
27.5
nce b
R
PE
R
PE
91.7
92.9
ta
)
(27.3
3/8
(Dis
[1(P), 5(R), 3(R) port]
M5 x 0.8
1.2 4 x ø7
(Pitch) (For mounting) (PE port)
74.8
G: Approx. 300
H: Approx. 600
Manual override
(Station n) (Station 1)
(Indicator light)
Individual EXH
spacer - + - + - + - + - +
R R R R R
80.5
45.5
32.5
1/4 4
(EXH port)
PE
215
196
1/4
[4(A), 2(B) port]
PE
98
A A
24
B B
Approx. 300
80.8
L: Dimensions
(Lead wire
n: Stations
(Pitch) n 2 3 4 5 6 7 8 9 10
length)
P = 33 30 L
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the same as
Grommet (G).
M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5
PE
PE
PE
198.2
220.8
216
179.2
201.8
197
PE
PE
PE
(Indicator light)
84.5
89.6
100.9
98.5
47
Series VF
Specific Product Precautions 1
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning Caution
Regardless of an electric signal for the solenoid valve, the 1. Connector attachment/detachment
manual override is used for switching the main valve. • To attach a connector, hold the lever and connector unit between
Connected actuator is started by manual operation. Use your fingers and insert straight onto the pins of the solenoid valve
the manual override after confirming that there is no so that the lever’s pawl is pushed into the groove and locks.
danger. • To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
Non-locking push type connector straight out.
Pin Connector
Push-turn locking slotted type
Groove Socket
Lead wire
Locked position Lever
LOCK
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the ends of the
core wires evenly into the sockets, and then crimp with a crimping
tool. When this is done, take care that the coverings of the lead wires
do not enter the core wire crimping area. (Please contact SMC for
details on the crimping tool.)
Core wire
crimping area Crimping area
Socket
Push down on the manual override with a small flat head screwdriver Core wire
(Part no.: DXT170-71-1)
until it stops. Turn it clockwise by 90 to lock it. Turn it counterclockwise Lead wire
to release it.
Covering
LOCK
Plug Connector Lead Wire Length How to Use DIN Terminal Connector
The DIN terminal with an IP65 (enclosure) is protected against dust
Caution and water, however, it must not be used in water.
Plug connector lead wires have a standard length of 300
mm, however, the following lengths are also available.
Caution
Connection
How to Order Connector Assembly 1) Loosen the set screw and pull the connector out of the solenoid valve
terminal block.
DC : V200-30-4A- 2) After removing the set screw, insert a flat head screwdriver, etc. into
the notch on the bottom of the terminal block and pry it open,
100 VAC : V200-30-1A- separating the terminal block and the housing.
3) Loosen the terminal screws on the terminal block, insert the core of the
lead wire into the terminal, and attach securely with the terminal
200 VAC : V200-30-2A-
screws.
In addition, when using the DC mode type with a surge voltage
Other AC voltages : V200-30-3A- suppressor (polar: S and Z types), connect wires corresponding to the
polarity (+ or –) that is printed on the terminal block.
Without lead wire : V200-30-A 4) Secure the cord by fastening the ground nut.
(With a connector and 2 sockets) In the case of connecting wires, select cabtire cords carefully because if
those out of the specified range (ø4.5 to ø7) are used, it will not be
Lead wire length able to satisfy IP65 (enclosure).
Nil 300 mm
Tighten the ground nut and set screw within the specified range of
torque.
6 600 mm
10 1000 mm
15 1500 mm Ground nut
Tightening torque Set screw
20 2000 mm Tightening torque
1.84 to 2.77 lbf·ft
25 2500 mm (2.5 to 3.75 N·m) 0.37 to 0.44 lbf·ft
30 3000 mm (0.5 to 0.6 N·m)
Precautions
Plug in and pull out the connector vertically without tilting to one side.
Applicable cable
Cable O.D.: ø4.5 to ø7
(Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to
JIS C 3306
49
Series VF
Specific Product Precautions 3
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
8.5
with a surge voltage suppressor (polar: S and (+) (–)
Z types), connect wires to terminal 1 and 2
corresponding to the polarity (+ or –) as
shown on the right figure.
How to Order DIN Connector 3) Secure the cord by fastening the ground nut.
Caution In the case of connecting wires, select cabtire cords carefully because if
those out of the specified range (ø4.5 to ø7) are used, it will not be able
Without indicator light to satisfy IP65 (enclosure).
DC, AC, Common to all voltages: V200- -1 Tighten the ground nut and set screw within the specified range of
torque.
With indicator light
A
DC 6-2
200-6 Set screw
Polar type ( Z) : V200- -3- bly
V Tightening torque
ssem 0.37 to 0.44 lbf·ft
er a (0.5 to 0.6 N·m)
Non-polar type ( U) : V200- -5- ck cov
l blo
Terminal block
na Grommet cover
Rated voltage mi
Ter (Rubber)
05 24 VDC
Washer
06 12 VDC Ground nut Ground terminal
Tightening torque screw
AC ( Z) : V200- -7- 1.84 to 2.77 lbf·ft Tightening torque
(2.5 to 3.75 N·m) 0.37 to 0.44 lbf·ft
Connector specifications Rated voltage
(0.5 to 0.6 N·m)
Terminal screw
61 D type 01 100/110 VAC [115 VAC] (2 locations)
63 Y type 02 200/220 VAC [230 VAC] Tightening torque
0.37 to 0.44 lbf·ft
07 240 VAC (0.5 to 0.6 N·m)
Note) For 24 VAC, the part no. is
V200-61-5-B.
63 Applicable cable
Circuit diagram with light (Built-in connector) Cable O.D.: ø4.5 to ø7
(Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to
DC ( Z) circuit diagram DC ( U) circuit diagram
JIS C 3306
LED Coil 0W
40 ms
Black (–)
Diode • Since the voltage will drop by approx. 0.5 V due to the transistor, pay
DIN or Conduit terminal attention to the allowable voltage fluctuation. (For details, refer to the
solenoid specifications of each type of valve.)
With light/surge voltage suppressor ( Z) Polarity protection diode
Polarity protection diode
Diode
(+)
(+)
LED
Coil Coil Diode
PWM circuit
(–)
For DIN type, installed
in the connector LED
Non-polar type
(–)
With surge voltage suppressor ( R)
(+, –)
<AC>
S type is not available, since a rectifier prevents surge voltage
Varistor Coil
generation.
(–, +) Grommet or L/M-type plug connector DIN or Conduit terminal
Grommet or L/M-type plug connector With light/surge voltage suppressor ( Z) With light/surge voltage suppressor ( Z)
With light/surge voltage suppressor ( U) (~) (~)
LED NL Note)
(+, –) Varistor Coil Varistor Coil
51
Series VF
Specific Product Precautions 5
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Caution
When fittings are used, they may interfere with one another depending on their types and sizes. Therefore, the dimensions of the fittings to be
used should first be confirmed in their respective catalogs.
Fittings whose compliance with the VF series is already confirmed are stated below. If the fitting within the applicable range is selected, there will
not be any interference.
52
Low Wattage Specification (VF1000/3000)
Specific Product Precautions 6
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning Caution
1. Non-locking push type [Standard] 1. Connector attachment/detachment
Press in the direction of the arrow. • To attach a connector, hold the lever and connector unit between
your fingers and insert straight onto the pins of the solenoid valve
so that the lever’s pawl is pushed into the groove and locks.
• To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
connector straight out.
Cover
Groove
2. Push-turn locking slotted type [D type] Pin
After pushing down, turn in the direction of the arrow. If it is not
Cover
turned, it can be operated the same way as the non-locking push Groove
type. Pin Lever
DC polarity indication
Locked position -+ Socket
Part no. DXT170-71-1
Connector Lead wire
PUSH
LOCK
Hook
Core wire
crimping area Crimping area
3. Push-turn locking lever type [E type]
Socket Core wire
After pushing down, turn in the direction of the arrow. If it is not Lead wire
turned, it can be operated the same way as the non-locking push 0.2 to 0.33 mm2
Max. cover diameter: ø1.7 mm
type. Hook Covering
Locked position
LOCK
• Attachment
Insert the sockets into the square holes of the connector (with +, –
indication), and continue to push the sockets all the way in until they
lock by hooking into the seats in the connector. (When they are
Caution pushed in, their hooks open and they are locked automatically.)
When locking the manual override with the push-turn locking type (D Then, confirm that they are locked by pulling lightly on the lead wires.
or E type), be sure to push it down before turning. • Detachment
Turning without first pushing it down can cause damage to the To detach a socket from a connector, pull out the lead wire while
manual override and other trouble such as air leakage, etc. pressing the socket’s hook with a stick having a thin tip (approx. 1
mm). If the socket will be used again, first spread the hook outward.
53
Low Wattage Specification (VF1000/3000)
Specific Product Precautions 7
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Caution 4. Precautions
Plug in and pull out the connector vertically without tilting to one side.
1. L/M-type plug connector 5. Applicable cable
<DC>
(+, −) Cable O.D: ø3.5 to ø7
Varistor Coil (Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306
(−, +)
LED
<AC> (~) Ground nut
LED Tightening torque
Varistor Coil Set screw
1.22 to 1.84 lbf·ft
(1.65 to 2.5 N·m) Tightening torque
(~) 0.22 to 0.3 lbf·ft
Washer (0.3 to 0.4 N·m)
Grommet
2. DIN terminal (Rubber)
Housing
<DC> (Location for
(Voltage symbol) light mounting)
With surge voltage suppressor (DS, DOS, YS,YOS) Refer to the table Terminal block
(+, −) below.
Tightening torque Terminal Notch
Varistor Coil 0.15 to 0.18 lbf·ft screw
(0.2 to 0.25 N·m) (3 locations)
(−, +)
<AC>
(−, +)
LED Caution
With indicator light (DZ, YZ) DIN terminal (D)
(~)
NL
Without indicator light SY100-61-1
Varistor Coil With indicator light
(~) Rated voltage Voltage symbol Part no.
NL: Neon light 24 VDC 24 V SY100-61-3-05
12 VDC 12 V SY100-61-3-06
Note) If a varistor surge voltage suppressor is used, there is some 100 VAC 100 V SY100-61-2-01
residual voltage to the protection element and rated voltage. 200 VAC 200 V SY100-61-2-02
Therefore, pay attention to the surge voltage protection on the 110 VAC 110 V SY100-61-2-03
controller side. 220 VAC 220 V SY100-61-2-04
Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its specifications. The product herein described is basically provided for peaceful use in
Since the product specified here is used under various operating conditions, its manufacturing industries.
compatibility with specific equipment must be decided by the person who designs If considering using the product in other industries, consult SMC beforehand and
the equipment or decides its specifications based on necessary analysis and test
exchange specifications or a contract if necessary.
results. The expected performance and safety assurance of the equipment will be
If anything is unclear, contact your nearest sales branch.
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the Limited warranty and Disclaimer/
equipment.
2. Only personnel with appropriate training should operate
Compliance Requirements
machinery and equipment. The product used is subject to the following “Limited warranty and Disclaimer”
The product specified here may become unsafe if handled incorrectly. The and “Compliance Requirements”.
assembly, operation and maintenance of machines or equipment including our Read and accept them before using the product.
products must be performed by an operator who is appropriately trained and
experienced. Limited warranty and Disclaimer
3. Do not service or attempt to remove product and machinery/
equipment until safety is confirmed. 1. The warranty period of the product is 1 year in service or 1.5 years after
1. The inspection and maintenance of machinery/equipment should only be the product is delivered, whichever is first. 2)
performed after measures to prevent falling or runaway of the driven objects Also, the product may have specified durability, running distance or
have been confirmed. replacement parts. Please consult your nearest sales branch.
2. When the product is to be removed, confirm that the safety measures as
mentioned above are implemented and the power from any appropriate source 2. For any failure or damage reported within the warranty period which is clearly our
is cut, and read and understand the specific product precautions of all relevant responsibility, a replacement product or necessary parts will be provided.
products carefully. This limited warranty applies only to our product independently, and not to any
3. Before machinery/equipment is restarted, take measures to prevent other damage incurred due to the failure of the product.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety 3. Prior to using SMC products, please read and understand the warranty terms
measures if the product is to be used in any of the following and disclaimers noted in the specified catalog for the particular products.
conditions. 2) Vacuum pads are excluded from this 1 year warranty.
1. Conditions and environments outside of the given specifications, or use A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
outdoors or in a place exposed to direct sunlight.
or failure due to the deterioration of rubber material are not covered by the limited warranty.
2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment, combustion
and recreation, or equipment in contact with food and beverages, emergency Compliance Requirements
stop circuits, clutch and brake circuits in press applications, safety equipment
or other applications unsuitable for the standard specifications described in the 1. The use of SMC products with production equipment for the manufacture of
product catalog. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
3. An application which could have negative effects on people, property, or
animals requiring special safety analysis. 2. The exports of SMC products or technology from one country to another are
4. Use in an interlock circuit, which requires the provision of double interlock for governed by the relevant security laws and regulations of the countries involved
possible failure by using a mechanical protective function, and periodical in the transaction. Prior to the shipment of a SMC product to another country,
checks to confirm proper operation. assure that all local rules governing that export are known and followed.
Revision
Revision history
history
Edition B Addition of rated voltage 24 VAC to Series VF1000/3000/5000 OZ
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.