Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Effective Treatment for

Obstructive Sleep Apnoea


The SleepCube Series of Positive Airway Pressure devices from DeVilbiss Healthcare is designed to meet the varied needs of people
suffering from Obstructive Sleep Apnoea (OSA) and Sleep Disordered Breathing (SDB).

Built to the highest standards the SleepCube series is a robust compact range of CPAP devices which can be used both in the home
and hospital environment. The SleepCubes’ multi voltage capability allows it to be used virtually anywhere in the world and it can
also be operated from a 12 V power source such as those found in a motor home. For the monitoring of patient compliance DeVilbiss
Healthcare has developed SmartCode and SmartLink which are available for use with all models of SleepCube.

SleepCube Standard
The SleepCube Standard is the first in the range of sleep therapy devices from DeVilbiss
Healthcare. It is a fixed pressure CPAP delivering constant pressure all night from 3 - 20
cm H2O.

SleepCube Standard Plus


Now with
SmartFlex TM
The SleepCube Standard Plus has all the features of a SleepCube Standard device with
Inside the addition of SmartFlex expiratory relief, designed to lower the average pressure
throughout the night and increase comfort for the user.

SleepCube Auto Plus


Now with The SleepCube Auto Plus has a unique auto adjusting algorithm that responds to
SmartFlex TM

apnoeas, hypopnoeas and snoring to deliver the most effective therapy whilst sleeping.
Inside
Now with the added SmartFlex expiratory relief for increased patient adherence.

SleepCube AutoBilevel
The AutoBilevel adds an extra level of comfort for Bilevel users. Using our ‘proven’ auto-
adjusting algorithm the AutoBilevel constantly monitors for apnoeas and events. Upon
their detection the Bilevel pressure automatically adjusts to deliver the best possible
treatment during sleep.

SleepCube BiLevel ST
The SleepCube BiLevel ST is designed to enhance the breathing of patients with
spontaneous respiration. It does not breathe for the patient but instead supports those
who suffer from chronic respiratory failure, breathing difficulties or OSA. Features include
a customisable trigger, real time display and a pressure range of 3 - 25 cm H2O.
Patient ID: 112233 Patient ID2 kl12mm
Patient ID: 112233 Patient ID2 kl12mm
First Name: Irene Last Name: Becker
First Name: Irene Last Name: Becker
Gender: Female Birth Date: 23.09.1990
Gender: Female Birth Date: 23.09.1990
Height: 1 m 70 cm Weight: 60 kg
Height: 1 m 70 cm Weight: 60 kg
BMI: 20.8
BMI: 20.8
Address 1: Ludwigsburger Straße 5 Address 2:
Address 1: Ludwigsburger Straße 5 Address 2:
City: Heppenheim State/Province: Hessen
City: Heppenheim State/Province: Hessen
Postal Code: 64626 Country: Deutschland
Postal Code:
10.08.2010 Country:
646268:07:34 AM - 10.08.2010 4:03:42 PM: Deutschland
112233 - Irene Becker: 15.11.2010
Phone Number: 064355/8383834 Email Address: Irene.becker@smartlink.de
Phone Number: 064355/8383834 Email Address: Irene.becker@smartlink.de
(GMT+01:00) Amsterdam,
(GMT+01:00) Amsterdam,
Time Zone: Berlin, Bern, Rom,
Time Zone: Berlin, Bern, Rom,
Stockholm, Wien
Stockholm, Wien

Time
Time Statistics
Statistics -- Non-Delay
Non-Delay Mode
Mode
Time: 7.5 Hours
Time: 7.5 Hours

Time
Time Statistics
Statistics -- Delay
Delay Mode
Mode
Time: 0.0 Hours
Time: 0.0 Hours

SmartLink 2 Desktop Software Leak Statistics - Non-Delay Mode


The SmartLink Therapy Management System from DeVilbiss Healthcare
Mask Leak Time: 1.3% of total Exhale Puff or EPI: 0.5 Per hour
provides a simple means of monitoring and recording CPAP usage Average Leak: 30.0 L/Min Maximum Leak: 104.0 L/Min
and evaluates the effectiveness of CPAP therapy. Median Leak: 24.0 L/Min
90th Percentile
54.0 L/Min
Leakage:
95th Percentile
60.0 L/Min
Leakage:

Main Features Leak Statistics - Delay Mode


■■ Easily tracks patients and their equipment.
Pressure
Pressure Statistics
Statistics
Mask Leak Time: -- Non-Delay
0.0%
Non-Delay
of total Mode
Mode Exhale Puff or EPI: 0.0 Per hour
■■ User defined study durations. Average Leak:
Average Pressure:
0.0 L/Min
5.0 cmH2O
Maximum Leak:
Median Pressure:
0.0 L/Min
5.0 cmH2O
Average Pressure: 5.0 cmH2O 95th Percentile
Median Pressure: 5.0 cmH2O
Median Leak: 0.0 L/Min L/Min
95th Percentile 90th Percentile
Leakage:
■■ Allows remote setting adjustment. 95th Percentile
Pressure:
90th Percentile
Pressure:
5.5 cmH2O
5.5 cmH2O
90th Percentile
Pressure:
Pressure:
5.0 cmH2O
5.0 cmH2O
L/Min
Leakage:
Max Pressure: 5.9 cmH2O
Max Pressure: 5.9 cmH2O
■■ Efficient workflow for setting up new patients, new devices and
managing patient studies.
■■ Auto-detects new study data on data card and imports into the
software.
1/4 Created
1/4 Created by
by DeVilbiss
DeVilbiss SmartLink®
SmartLink® Report
Report Generator
Generator Version
Version 2.2.1.0
2.2.1.0
■■ Customisable Reports – although the software comes as standard
with six report templates, new report templates can be created to
show and hide information as required.
■■ Reports can be easily exported into various formats.
10.08.2010 8:07:34 AM - 10.08.2010 4:03:42 PM: 112233 - Irene Becker: 15.11.2010
■■Security Options – enabling three different permission levels to be
adopted;
1. Read only
2. Read and write
2/4 Created by DeVilbiss SmartLink® Report Generator Version 2.2.1.0
3. Administrator – delete, modify reports, database functions
■■ SmartLink Dashboard can be customised to display features such
as reminders, low adherence % and AHI notification.
■■ Personal Reminders can be stored in calendar view for ease of
10.08.2010 8:07:34 AM - 10.08.2010 4:03:42 PM: 112233 - Irene Becker: 15.11.2010
patient follow up.
Leak Statistics - Non-Delay Mode
■■ A direct connection to download patient information directly
to the PC has been developed alongside the existing download
Mask Leak Time: 1.3% of total Exhale Puff or EPI: 0.5 Per hour
facility from the data card. Average Leak: 30.0 L/Min Maximum Leak: 104.0 L/Min
90th Percentile
Median Leak: 24.0 L/Min 54.0 L/Min
■■ Databases can be added to local and shared networks. Leakage:
95th Percentile
It is possible to import / export information from other locations Leakage:
60.0 L/Min

or PC’s. All patient databases from previous versions of the


SmartLink software can be imported and added to a new Leak Statistics - Delay Mode
database. Mask Leak Time: 0.0% of total Exhale Puff or EPI: 0.0 Per hour
Average Leak: 0.0 L/Min Maximum Leak: 0.0 L/Min
■■ Documents can be attached directly to patient notes within the 95th Percentile
Median Leak: 0.0 L/Min L/Min
Leakage:
database. 90th Percentile
L/Min
Leakage:
■■ SmartCode, Remote Control Software and Oximetry Software all
built in.

AHI Statistics - Non-Delay Mode


SmartCode
SmartCode is a simple and effective way to remotely track compli-
ance data. SmartCode is an alpha-numeric code that is shown on
the display of the SleepCube which provides summary data for
the previous day, 7 days, 30 days, 90 days or cumulative. The
SmartCode reading and an internet connection or SmartLink 2
desktop software is all that is needed to access the patients’ infor-
mation. The SleepCube device does not need to be directly con-
nected to the computer, nor does it use memory cards.
SleepCube with SmartCode display
SmartCode is available in every model of SleepCube without any
additional fees, equipment or software and provides insightful
data that can be used to determine the patients’ compliance.

Apnea/Hypopnea Index High Leak Flow Time (>95 L/Min)


35 35

30 30
% of Time Used
Events/Hour

25 25

20 20

15 15
12
10 9 10
10 10
5.5 5.5 5 5
5 5

0 0
Last 90 Days Last 30 Days Last 7 Days Last Day Last 90 Days Last 30 Days Last 7 Days Last Day

Non-Responding Event Index Exhale Puff Index


35 35

30 30
Events/Hour
Events/Hour

25 25

20 20

15 15

10 10

5 5 2 2 3
1.75 1.5 0.25 1
1
0 0
Last 90 Days Last 30 Days Last 7 Days Last Day Last 90 Days Last 30 Days Last 7 Days Last Day

Model Parameters
SleepCube % of days at least 4 or 5 hours (min threshold)
Standard Day Count
Days at least 4 or 5 hours
Average hours per day
While breathing hours
SleepCube As above including the following parameters:
Standard Plus Apnoea / Hypopnoea Index – number of apnoea / hypopnoea events detected/hr
Optional Channels Non-Responding Event Index – number of non-responding events detected/hr
High Leak Flow Time – % of therapy time that the system leak was above 95 l/min
EPI – Exhale Puff Index (mouth breathing)
SleepCube Auto Plus As above including the following parameters:
SleepCube BiLevel S Time at Pressure – 90th / 95th percentile pressure
Pressure Plateau – percentage of time at upper pressure limit
SleepCube BiLevel ST As above including the following parameters:
% Machine Inspiration – the % breaths in which the Timed Backup feature has been initiated on Inspiration
% Machine Expiration – the % breaths in which the Timed Backup feature has been initiated on Expiration
CPAP Pressure

Features & Accessories


Exhale
Rounding
SmartFlex – Expiratory Relief 1-5 Inhale
Rounding
SmartFlex increases the comfort and adherence to the CPAP 1-5
therapy by reducing the pressure when the patient is exhaling.
SmartFlex has three settings, each of which reduces the CPAP
pressure by 1 cm H2O during exhalation. SmartFlex can either
be used for the whole night or simply during the ramp period
to enable patients to fall asleep more easily. If an apnoea, Flex 1
hypopnoea or a snore is detected SmartFlex will turn off and Flex 2 Flex 3
will only resume once events are no longer detected. SmartFlex
SmartFlex and Flow Rounding settings
is available in the SleepCube Standard Plus and Auto Plus.

Flow Rounding
Flow Rounding is a patented technology from DeVilbiss Healthcare
which enables a smooth transition from inspiratory (IPAP) to
expiratory pressure (EPAP). There are 6 levels of flow rounding
with level 0 having the steepest slope and quickest transition
and level 5 having the gentlest slope and slowest transition.
By tailoring the pressure waveform (see diagram) according to
the users requirements, the chances of waking the patient are
reduced and comfort is increased. Flow Rounding is available in
SleepCube Standard Plus, Auto Plus, BiLevel S and BiLevel ST.
Optional SleepCube Heated Humidifier
Heated Humidifier
The optional heated humidifier integrates seamlessly into the
SleepCube CPAP devices and offers the patient 10 heat settings
to ensure maximum comfort during therapy.

SmartLink Module
(For Sleep Labs and Physicians only)
The SmartLink module can be added to any SleepCube device
increasing its capability from being a CPAP to a complete therapy
management system. When attached to a SleepCube Auto Plus,
up to 72 hours of detailed therapy data can be collected, giving
SmartLink Module and Software package
all the parameters needed for overnight assessment or titration
purposes.

Pulse Oximeter
By adding the oximeter accessory to the SleepCube, it becomes
the ideal device for conducting CPAP titrations and split night
studies. A selection of different probes are available including
finer probes and an ear probe. The oximetry reports are combined
within the SmartLink 2 desktop software for greater ease of
patient analysis.

SleepCube with SmartLink Module and pulse oximeter attached


Specifications SleepCube SleepCube SleepCube SleepCube SleepCube
Standard Standard Plus Auto Plus AutoBilevel BiLevel ST
Dimensions (H x W x L) 10.7 x 16.5 x 17.5 cm
Weight 1.2 kg 1.2 kg 1.2 kg 1.2 kg 1.2 kg
Pressure Range (cm H2O) 3 - 20 CPAP 3 - 20 CPAP 3 - 20 CPAP 3 - 25 BiLevel 3 - 25 BiLevel
Operation Modes CPAP CPAP CPAP, CPAP, CPAP,
AutoAdjust Spontaneous, Spontaneous,
Spontaneous
Timed,
Timed only
Operating 5° C to 40° C; 0 % to 95 % R.H. non-condensing
Atmospheric Conditions Sea level to 2,600 m
Storage & Transportation - 40° C to + 70° C; 0 % to 95 % R.H. non-condensing
Sound Level 26 dBA (tested per ISO 17510)
Power Consumption Maximum 65 W from AC power source (PAP device only)
Electrical Requirements 100 - 240 VAC, 50/60 Hz
Equipment classification with
respect to protection from elec- Class II
tric shock
Degree of protection from
Type BF Applied Part
electric shock
Degree of protection
IPX1
against ingress of liquids
Auto Altitude Adjustment 3 3 3 3 3
Max. Operating Altitude ca. 2750 m 2750 m 2750 m 2600 m 2600 m
Ramp Time Linear Ramp 0 - 45 in 5 min. increments
Auto ON/OFF 3 3 3 3 3
SmartFlex – 3 3 – –
Quick-View option – 3 3 – –
Real-time Display – – – 3 3
Flow Rounding – 3 3 3 3
Event Detection (AP, HYP, SN,) – 3 3 3 3
Visual Mask Off Alert 3 3 3 3 3

Distributor:
DeVilbiss Healthcare Ltd.
Unit 3, Bloomfield Park, Bloomfield Road
Tipton, West Midlands DY4 9AP
United Kingdom
Phone + 44 (0) 121 521 3140
Fax + 44 (0) 121 521 3141
www.devilbisshc.com
enquiries@devilbisshc.com
DeVilbiss Healthcare has a policy of continuing improvement, we therefore reserve the right to vary
details at any time without notice. SleepCube is a registered trademark of DeVilbiss Healthcare. 0612/V12/SD/000690191.UK