TJF-Q170V Duodenoscope: Supporting Your Standard of Care

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TJF-Q170V Duodenoscope

Supporting Your Standard of Care


TJF-Q170V Duodenoscope
Support Your Standard of Care

Main Features
Guidewire Locking Capability Distal-end Flushing Adaptor
The V-groove facilitates Ensures controlled
fast and secure distribution of detergent
guidewire locking of and disinfectant
0.035 inch and 0.025 solution to the distal tip
inch guidewires with of the endoscope
dual system at the during manual MAJ-2319 distal-end flushing adaptor
distal end. reprocessing. for TJF-Q170V
Center Lock Side Lock

Narrow Band Imaging (NBI) Waterproof Connector


Designed for facilitating the observation of capillaries and The newly designed connector is fully submersible and
2.2 Specifications
other structures on the mucosal surface. It may help therefore eliminates the need for a water-resistant cap, while
physicians to see and identify suspicious tissue. decreasing the risk
„ ofSpecifications
damage due to accidental immersion.

Model TJF-Q190V
Single-use Distal Cover Optical Field of view 100q
system Direction of view Backward side viewing 15q
The MAJ-2315 single-use distal cover allows for visualization Depth of field 5 – 60 mm
Insertion Distal end outer
of the distal end and better section diameter with MAJ-2315
ø 13.5 mm

Water-resistant Distal
capend enlarged
access for reprocessing 1 Instrument channel
1 2
3
outlet
accessories during manual 2 Air/water nozzle 4
Conventional scope 3 Objective lens
TJF-Q170V 5 UP
cleaning. The cover is (TJF-145/150) 4 Light guide lens
6
LEFT
5 Forceps elevator

transparent is destroyed during 6 Guidewire-locking


groove RIGHT
DOWN
removal, preventing MAJ-2315 single-use distal cover Insertion tube outer
for TJF-Q170V diameter
ø 11.3 mm
unintended reuse. Insertion section
1240 mm
working length
Instrument Channel inner diameter ø 4.2 mm
channel Minimum visible
Specifications distance*1
10 mm

Direction from which


Field of view 100° Direction from which EndoTherapy
EndoTherapy
Instrument accessories enter and
Optical accessories enter and exit
Direction of view Backward side viewing 15° Channel exit the endoscopic
System the endoscopic image
image

Depth of field 5 to 60 mm Airflow rate*2


Up 120°
25 cm3/s
Bending Angulation range UP 120q
Distal end outer diameter 13.5 mm section
Down 90º
DOWN 90q
RIGHT 110q
Bending Section Angulation range LEFT 90q
Total length Right 110° 1560 mm

Insertion Distal end enlarged *1 Distance from the distal end of the endoscope.
Left 90°
*2 Standard when CLV-190 (high air pressure) is used.
Section
Total Length 1,560 mm
Insertion tube outer diameter 11.3 mm
Compatible
OLYMPUS CV-170 video system center
Working length 1,240 mm Optera System

Instrument Channel inner diameter 4.2 mm TJF-Q190V OPERATION MANUAL 23


Channel Minimum visible distance 10 mm from the distal end

Ordering Information
Order Number Description Quantity

TJF-Q170V 170-series Duodenovideoscope 1 PC

MAJ-2315 Single Use Distal Cover 20 PC


M00386EN· 2/21 · OKM

MAJ-2319 Distal-end Flushing Adapter 1 PC

MAJ-2358 Connecting Tube for OER-AW 1 PC