Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 23

Antenna Survey Report (ASR)

Basic Site Information Site ID: BLA318W


Site Name: LAMBARENE LNF4

Site Details

Antenna
Site Type Building Height Height Longitude Latitude Structure type

Outdoor 35 10.21348 -0.66986 GBT

Site Address Street District Name

SCFT DETAILS

Name Visit Date Company Phone


Prepared by ERICSSON
19-Jan-2022

Add a New Column if we have more than 2 Antennas on any Sector


Technology Attribute Sector 01 Sector 02 Sector 03
Ant01 Ant02 Ant01 Ant02 Ant01
Height 35 NA 35 NA 35
Azimuth (compass magnetic) 30 NA 120 NA 200
Antenaa Manufacturer BASE STATION ANTENNA NA BASE STATION ANTENNA NA BASE STATION ANTENNA
Antenna Model SXTWL2WH-17/18-65/65IE-IVT-R NA SXTWL2WH-17/18-65/65IE-IVT-R NA SXTWL2WH-17/18-65/65IE-IVT-R
U900
Antenna Band QUAD BAND NA QUAD BAND NA QUAD BAND
Antenna Ports 8-ports NA 8-ports NA 8-ports
Mechanical Tilt 2 NA 2 NA 2
Electrical Tilt 3 NA 3 NA 3

1 of 23
Sector 03 Sector 04
Ant02 Ant01 Ant02
NA
NA
NA
NA
NA
NA
NA
NA

2 of 23
Single Cell Function Test (SCFT)
Site ID: BLA318W Site Name: LAMBARENE LNF4 Cell ID
New Site: Site Connected to RNC:
Others: Last Drive Performed:
No. Activity/Process MS1 MS2 MS3/Dongle Sector A Sector B Sector C result Remarks Count Status

1 MNC Y 3 3 3
2 MCC Y 628 628 628
3 LAC Y 316 316 316
4 RAC Y 4 4 4
Idle
5 ARFCN Y 10687 10687 10687
6 PSC Y 71 72 73
7 RSCP(Close to site) Y -67.85 -72.44 -76.04 RSCP >= -92dBm for 90% samples Meeting Criteria
8 Ec/Io(Close to site) Y -13.45 -14.94 -14.44 Ec/Io >=-12 dB for 90% samples to 95% samples Meeting Criteria
Connection 9 Voice Call Setup Success rate (MO) Y 100.00% 100.00% 100.00% MOC & MTC >= 95% 5/5/'5 Meeting Criteria
12 HSUPA Setup Success rate Y 100.00% 100.00% 100.00% 95.00% Meeting Criteria
More than 7.2 Mbps peak without any bandwith Meeting Criteria
13 HSDPA Setup Success rate Y 100.00% 100.00% 100.00% 95.00%
bottleneck. E2E backhaul to be provided with a 20%
More thanto2meet
Mbpsthis
without
targetany bandwith bottleneck. E2E Meeting Criteria
14 HSDPA Throughput (Mbps) Y 33.48 21.12 35.4 Overrate
backhaul to be provided with a 20% Overrate to meet this
15 HSUPA Throughput Y 6.75 7.84 6.36 target
Target shall be applicable with Dongle in static condition
Meeting Criteria
16 Handover Function Y Y Y Y Y Target shall be applicable with Dongle in static condition
Meeting Criteria
Both Soft and Softer Handover needs to be checked. Meeting Criteria
17 3G to 3G Y Y Y Y Y Target >=98%
Handover Target >=98% 3 times outgoing and 3 times incoming if
18 PS Soft HO Y Y Y Y Meeting Criteria
applicable
Target >=98% 3 times clockwise and 3 times anti- Meeting Criteria
19 PS Softer HO Y Y Y Y clockwise
Static tests only. Meeting Criteria
20 PDP context activation Success rate Y 100 100 100 Target >=95% attempts =20
Average of all samples.
22 Latency(HSPA) Y 361 463 279 This KPI is a hygiene and not an acceptance KPI Hygiene KPI
Target shall be applicable with Dongle in static condition
23 CS call setup time Y 0.00 0.00 0.00 Hygiene KPI
24 PS call setup time Y NA NA NA Hygiene KPI
25 CS drop call rate Y 0 0 0 CS <= 1% & PS <= 1.5% Meeting Criteria
26 PS drop call rate Y 0 0 0 CS <= 1% & PS <= 1.5% Meeting Criteria
27 Packet drop Y 0 0 0 ping test Meeting Criteria
28 Packet retransmission Y 0 0 0 If Applicable - ping test Hygiene KPI

Remarks (Comments):

SP Signature Bharti Signature: Date:


PSC PLOT

RSCP PLOT

ECNO PLOT
UARFCN PLOT

HANDOFF PLOT
ACTIVE SET PLOT

EVENT PLOT
Sec-1

Sec-2

Sec-3
Sec-1

Sec-2
Sec-3
Sec-1

Sec-3
Sec-3