Professional Documents
Culture Documents
Ssvu2100 Bla318w-U2100 Report
Ssvu2100 Bla318w-U2100 Report
Site Details
Antenna
Site Type Building Height Height Longitude Latitude Structure type
SCFT DETAILS
1 of 23
Sector 03 Sector 04
Ant02 Ant01 Ant02
NA
NA
NA
NA
NA
NA
NA
NA
2 of 23
Single Cell Function Test (SCFT)
Site ID: BLA318W Site Name: LAMBARENE LNF4 Cell ID
New Site: Site Connected to RNC:
Others: Last Drive Performed:
No. Activity/Process MS1 MS2 MS3/Dongle Sector A Sector B Sector C result Remarks Count Status
1 MNC Y 3 3 3
2 MCC Y 628 628 628
3 LAC Y 316 316 316
4 RAC Y 4 4 4
Idle
5 ARFCN Y 10687 10687 10687
6 PSC Y 71 72 73
7 RSCP(Close to site) Y -67.85 -72.44 -76.04 RSCP >= -92dBm for 90% samples Meeting Criteria
8 Ec/Io(Close to site) Y -13.45 -14.94 -14.44 Ec/Io >=-12 dB for 90% samples to 95% samples Meeting Criteria
Connection 9 Voice Call Setup Success rate (MO) Y 100.00% 100.00% 100.00% MOC & MTC >= 95% 5/5/'5 Meeting Criteria
12 HSUPA Setup Success rate Y 100.00% 100.00% 100.00% 95.00% Meeting Criteria
More than 7.2 Mbps peak without any bandwith Meeting Criteria
13 HSDPA Setup Success rate Y 100.00% 100.00% 100.00% 95.00%
bottleneck. E2E backhaul to be provided with a 20%
More thanto2meet
Mbpsthis
without
targetany bandwith bottleneck. E2E Meeting Criteria
14 HSDPA Throughput (Mbps) Y 33.48 21.12 35.4 Overrate
backhaul to be provided with a 20% Overrate to meet this
15 HSUPA Throughput Y 6.75 7.84 6.36 target
Target shall be applicable with Dongle in static condition
Meeting Criteria
16 Handover Function Y Y Y Y Y Target shall be applicable with Dongle in static condition
Meeting Criteria
Both Soft and Softer Handover needs to be checked. Meeting Criteria
17 3G to 3G Y Y Y Y Y Target >=98%
Handover Target >=98% 3 times outgoing and 3 times incoming if
18 PS Soft HO Y Y Y Y Meeting Criteria
applicable
Target >=98% 3 times clockwise and 3 times anti- Meeting Criteria
19 PS Softer HO Y Y Y Y clockwise
Static tests only. Meeting Criteria
20 PDP context activation Success rate Y 100 100 100 Target >=95% attempts =20
Average of all samples.
22 Latency(HSPA) Y 361 463 279 This KPI is a hygiene and not an acceptance KPI Hygiene KPI
Target shall be applicable with Dongle in static condition
23 CS call setup time Y 0.00 0.00 0.00 Hygiene KPI
24 PS call setup time Y NA NA NA Hygiene KPI
25 CS drop call rate Y 0 0 0 CS <= 1% & PS <= 1.5% Meeting Criteria
26 PS drop call rate Y 0 0 0 CS <= 1% & PS <= 1.5% Meeting Criteria
27 Packet drop Y 0 0 0 ping test Meeting Criteria
28 Packet retransmission Y 0 0 0 If Applicable - ping test Hygiene KPI
Remarks (Comments):
RSCP PLOT
ECNO PLOT
UARFCN PLOT
HANDOFF PLOT
ACTIVE SET PLOT
EVENT PLOT
Sec-1
Sec-2
Sec-3
Sec-1
Sec-2
Sec-3
Sec-1
Sec-3
Sec-3