Est3 Remote Annunciators: 3-Anncpu3, 3-Lcdann, 3-6ann, 3-10ann, 3-Evxxx, 3-4ann
Est3 Remote Annunciators: 3-Anncpu3, 3-Lcdann, 3-6ann, 3-10ann, 3-Evxxx, 3-4ann
EST3 Remote
Annunciators
3-ANNCPU3, 3-LCDANN, 3-6ANN,
3-10ANN, 3-EVxxx, 3-4ANN
EN54-2:1997+A1 and
EN54-4:1997+A1:2002+A2
pending
NETWORK A
NETWORK B
24 VDC
24 VDC
SPARE
1 Power limited
circuit Graphic Annunciator
1 2 3 4 5 6 7 8 9 10
To TB1 on 3-ANNCPU3
NOTES:
1. All wiring except earth Wire Specifications
TX RX
RX TX
TX RX
RX TX
TX RX
RX TX
TX RX
Specifications
Catalog Number 3-ANNCPU3 3-ANNSM 3-LCD 3-LCDXL1
Agency Listings UL, ULC, FM, CE, LPCB EN54* pending.
Mounts over 3-ANNCPU
Mounting Space Two Spaces One Space Mounts over 3-ANNCPU
plus two spaces.
Communication Format RS-485 N/A N/A N/A
Current @ 24 Vdc
Standby 144 mA 10mA 40mA 48mA
Alarm 144 mA 10mA 42mA 50mA
Wiring Termination Plug in terminal strip
Twisted Pair 18-14 AWG
Wiring Size
(0.75-1.5 mm²) N/A
5000 ft (1524m)
Max. Wire Distance
between any 3 panels
Relative Humidity 93% non condensing at 90° F (32° C)
Temperature Rating 0-49° C (32 - 120° F)
Wiring Styles Class A or Class B
Note: For a complete list of EST3 annunciator display and control modules please refer to Edwards literature sheet part number 85010-
0055.
* EN54-2:1997+A1 and EN54-4:1997+A1:2002+A2 pending
Engineering Specification
The Life Safety system shall incorporate annunciation of Alarm, units. The LCD interface must provide the ability to display custom
Supervisory, Trouble and Monitor operations. Annunciation must event messages of a minimum of 40 characters. The LCD must
be through the use of both LED display strips complete with a provide the emergency user, hands free viewing of the first and
means to custom label each LED as to its function. Where ap- last highest priority event. The last highest priority event must
plicable control switches must be provided. Switches with LEDs always display and update automatically. System events must
must provide positive feed back to the operator of remote equip- automatically be placed in queues. It shall be possible to view
ment status. An LCD display with basic common control LEDs specific event types separately. Having to scroll through a mixed
and switches shall be provided. The Common Control Switches list of events types is not acceptable. The total number of active
and LEDs provided as minimum will be: Reset switch and LED, events by type must be displayed. It must be possible to custom-
Alarm Silence switch and LED, Panel Silence switch and LED, Drill ize the designations of all user interface LEDs and switches for
switch and LED. It must be possible to add additional common local language requirements. It must be possible to route system
controls as required though the use of modular display / control event messages to specific annunciator locations.
Page 2 of 4 D ATA S H E E T 85010-0069
Not to be used for installation purposes. Issue 10
Dimensions
6.12 in
Semiflush Mount (15.55 cm) Surface Mount
2.75 in 2.75 in
(6.99 cm) (6.99 cm)
0.46 in (1.17 cm)
7.60 in 7.60 in
(19.31 cm) (19.31 cm)
TOP TOP
4ANN/B(-S)
13.19 in. 12.1 in. 13.19 in.
(33.5 cm) (30.7 cm) (33.5 cm)
6ANN/B(-S)
13.19 in. 12.1 in. 13.19 in.
(33.5 cm) (30.7 cm) (33.5 cm)
10ANN/B(-S)
12.1 in. 13.19 in. 12.1 in.
(30.7 cm) (33.5 cm) (30.7 cm)