Professional Documents
Culture Documents
26 - EC210B - Ajustamento Pobre Com RCV
26 - EC210B - Ajustamento Pobre Com RCV
26 - EC210B - Ajustamento Pobre Com RCV
Version Date
BR EXC 914 26 2 01/15/2009
Applies to
EC135B LC Volvo, EC140B LC Volvo, EC160B LC Volvo, EC160B NLC Volvo, EC160C L Volvo, EC160C NL Volvo, EC180B LC
Volvo, EC180C L Volvo, EC210B LC Volvo, EC210B LR Volvo, EC210B NLC Volvo, EC210C L Volvo, EC210C NL Volvo, EC235C
NL Volvo, EC240B LC Volvo, EC240B LR Volvo, EC240B NLC Volvo, EC240C L Volvo, EC240C NL Volvo, EC290B LC Volvo,
EC290B LR Volvo, EC290B NLC Volvo, EC290C L Volvo, EC290C NL Volvo, EC330B LC Volvo, EC330C L Volvo, EC360 LC Volvo,
EC360B LC Volvo, EC360B LR Volvo, EC360C L Volvo, EC360C NL Volvo, EC460B LC Volvo, EC460B LR Volvo, EC460C L Volvo,
EC700B LC Volvo, EW145B Volvo
Este Service Bulletin é para ser considerado apenas como uma informação técnica, e não está sujeito a nenhum programa
de reembolso fora da garantia normal.
Motivo
The operator may experience gradability issues due to a design change made on the RCV spools. The intent of the RCV
spool design change was to reduce operator lever efforts.
Figura 1
RCV section
1. Spool
(missing infotext)
1. A new RCV, containing different RCV spools, has been introduced in production at the applied s/n's stated below.
2. Also, new RCV spools can be supplied as service parts through the parts system. It is recommended to only replace
the RCV spools for boom and arm in cases of gradability issues and not to replace the complete RCV's.
3. In order to obtain the proper p/n's of the RCV spools you need specifically for your s/n machine, you must submit a
Techline report on the specific machine and issue. Your response will then include the p/n for the correct tolerance
RCV spools you need to order from parts.
Preliminary check
If operator doesn’t have any grading problem or unit doesn’t fall under the following scope, RCV doesn’t have to be
repaired.
NOTA:
Do not repair RCV without approval of CST. Contact CST and get the tolerance information of RCV. Spools should be
replaced with proper tolerance.